1
-
-
0004183998
-
IEEE guide: Test procedures for synchronous machines
-
IEEE Std 115-1995
-
IEEE Std 115-1995 IEEE guide: test procedures for synchronous machines[S]. 1996.
-
(1996)
-
-
-
2
-
-
0004183998
-
IEEE guide: Test procedures for synchronous machines
-
IEEE Std 115-2009
-
IEEE Std 115-2009 IEEE guide: test procedures for synchronous machines[S]. 2010.
-
(2010)
-
-
-
4
-
-
0019531112
-
Validation of synchronous machine models and derivation of model parameters from tests
-
de MELLO F P, HANNETT L H. Validation of synchronous machine models and derivation of model parameters from tests[J]. IEEE Trans on Power Apparatus and Systems, 1981, 100(2): 662-672.
-
(1981)
IEEE Trans on Power Apparatus and Systems
, vol.100
, Issue.2
, pp. 662-672
-
-
de Mello, F.P.1
Hannett, L.H.2
-
5
-
-
0020116805
-
Measurements of synchronous machine parameters under operating condition
-
SUGIYAMA T, NISHIWAKI T, TAKEDA S, et al. Measurements of synchronous machine parameters under operating condition[J]. IEEE Trans on Power Apparatus and Systems, 1982, 101(4): 895-904.
-
(1982)
IEEE Trans on Power Apparatus and Systems
, vol.101
, Issue.4
, pp. 895-904
-
-
Sugiyama, T.1
Nishiwaki, T.2
Takeda, S.3
-
6
-
-
80051814894
-
-
Chinese source
-
1993.
-
(1993)
-
-
-
7
-
-
80051814150
-
Application of the d, q-axis load rejection method to measuring parameters of synchronous electric machine
-
CHENG Zhongyun. Application of the d, q-axis load rejection method to measuring parameters of synchronous electric machine[J]. Large Electric Machine and Hydraulic Turbine, 1994(1): 32-36.
-
(1994)
Large Electric Machine and Hydraulic Turbine
, Issue.1
, pp. 32-36
-
-
Cheng, Z.1
-
8
-
-
80051807821
-
Measuring parameters of hydro-generator by using load rejection method
-
LI Xiaoxia, ZHANG Yan, GUO Lei. Measuring parameters of hydro-generator by using load rejection method[J]. Shaanxi Electric Power, 2007, 35(8): 42-44.
-
(2007)
Shaanxi Electric Power
, vol.35
, Issue.8
, pp. 42-44
-
-
Li, X.1
Zhang, Y.2
Guo, L.3
-
9
-
-
80051820061
-
Application of load rejection method to measure electromagnetism parameters on No. 5 generator of the Danjiangkou hydropower plant
-
HUANG Jian, XIAO Lichun, WANG Wei, et al. Application of load rejection method to measure electromagnetism parameters on No. 5 generator of the Danjiangkou hydropower plant[J]. South-to-North Water Transfers and Water Science & Technology, 2009, 7(6): 399-401.
-
(2009)
South-to-North Water Transfers and Water Science & Technology
, vol.7
, Issue.6
, pp. 399-401
-
-
Huang, J.1
Xiao, L.2
Wang, W.3
-
10
-
-
0034592092
-
Analysis of terminal voltage and calculation of parameters of synchronous machine switched out from bus system
-
ZHANG Ailing. Analysis of terminal voltage and calculation of parameters of synchronous machine switched out from bus system[J]. Proceedings of the CSEE, 2000, 20(12): 28-32.
-
(2000)
Proceedings of the CSEE
, vol.20
, Issue.12
, pp. 28-32
-
-
Zhang, A.1
-
11
-
-
41349083406
-
New load rejection test method for parameter estimation of synchronous generators
-
YUE Chenxi, ZHEN Wei, LIU Bosi, et al. New load rejection test method for parameter estimation of synchronous generators[J]. High Voltage Engineering, 2008, 34(2): 319-323.
-
(2008)
High Voltage Engineering
, vol.34
, Issue.2
, pp. 319-323
-
-
Yue, C.1
Zhen, W.2
Liu, B.3
-
12
-
-
0036602455
-
Identification of synchronous machine parameters using load rejection test data
-
BORTONI E D C, JARDINI J A. Identification of synchronous machine parameters using load rejection test data[J]. IEEE Trans on Energy Conversion, 2002, 17(2): 242-247.
-
(2002)
IEEE Trans on Energy Conversion
, vol.17
, Issue.2
, pp. 242-247
-
-
Bortoni, E.D.C.1
Jardini, J.A.2
-
13
-
-
33344471437
-
A new and efficient approach for analysis of a saturated synchronous generator under the load rejection test
-
WAMKEUE R, KAMWA I, BAETSCHER F, et al. A new and efficient approach for analysis of a saturated synchronous generator under the load rejection test[J]. Electric Power Components and Systems, 2006, 34(5): 539-563.
-
(2006)
Electric Power Components and Systems
, vol.34
, Issue.5
, pp. 539-563
-
-
Wamkeue, R.1
Kamwa, I.2
Baetscher, F.3
-
14
-
-
35148871621
-
Alternative approaches for linear analysis and prediction of a synchronous generator under partial-and full-load rejection tests
-
WAMKEUE R, JOLETTE C, KAMWA I. Alternative approaches for linear analysis and prediction of a synchronous generator under partial-and full-load rejection tests[J]. IET Electric Power Application, 2007, 1(4): 581-590.
-
(2007)
IET Electric Power Application
, vol.1
, Issue.4
, pp. 581-590
-
-
Wamkeue, R.1
Jolette, C.2
Kamwa, I.3
-
15
-
-
77955184624
-
Estimation of synchronous generator parameters from load rejection analytical responses
-
May 16-19, Prague, Czech Republic
-
WAMKEUE R, JOLETTE C, KAIROUS D. Estimation of synchronous generator parameters from load rejection analytical responses[C]//Proceedings of the 9th International Conference on Environment and Electrical Engineering, May 16-19, 2010, Prague, Czech Republic: 392-395.
-
(2010)
Proceedings of the 9th International Conference on Environment and Electrical Engineering
, pp. 392-395
-
-
Wamkeue, R.1
Jolette, C.2
Kairous, D.3
-
16
-
-
4944247055
-
IEEE guide for synchronous generator modeling practices and applications in power system stability analysis
-
IEEE Std 1110-2002
-
IEEE Std 1110-2002 IEEE guide for synchronous generator modeling practices and applications in power system stability analysis[S]. 2003.
-
(2003)
-
-
-
17
-
-
0036507341
-
A systematic approach in estimating the generator parameters
-
MOHAMED A, HUSSAIN A. A systematic approach in estimating the generator parameters[J]. Electric Power Components and Systems, 2002, 30(3): 301-313.
-
(2002)
Electric Power Components and Systems
, vol.30
, Issue.3
, pp. 301-313
-
-
Mohamed, A.1
Hussain, A.2
-
18
-
-
0035479968
-
Direct identification of continuous time delay systems from step responses
-
WANG Qingguo, GUO Xin, ZHANG Yong. Direct identification of continuous time delay systems from step responses[J]. Journal of Process Control, 2001, 11(5): 531-542.
-
(2001)
Journal of Process Control
, vol.11
, Issue.5
, pp. 531-542
-
-
Wang, Q.1
Guo, X.2
Zhang, Y.3
-
19
-
-
0035283924
-
Robust identification of continuous systems with dead-time from step responses
-
WANG Qingguo, ZHANG Yong. Robust identification of continuous systems with dead-time from step responses[J]. Automatica, 2001, 37(3): 377-390.
-
(2001)
Automatica
, vol.37
, Issue.3
, pp. 377-390
-
-
Wang, Q.1
Zhang, Y.2
-
20
-
-
38849114257
-
Identification from step responses with transient initial conditions
-
AHMED S, HUANG B, SHAH S L. Identification from step responses with transient initial conditions[J]. Journal of Process Control, 2008, 18(2): 121-130.
-
(2008)
Journal of Process Control
, vol.18
, Issue.2
, pp. 121-130
-
-
Ahmed, S.1
Huang, B.2
Shah, S.L.3
-
21
-
-
0033352702
-
Methodology development for estimation of armature circuit and field winding parameters of large utility generators
-
KARAYAKA H B, KEYHANI A, AGRAWAL B, et al. Methodology development for estimation of armature circuit and field winding parameters of large utility generators[J]. IEEE Trans on Energy Conversion, 1999, 14(4): 901-907.
-
(1999)
IEEE Trans on Energy Conversion
, vol.14
, Issue.4
, pp. 901-907
-
-
Karayaka, H.B.1
Keyhani, A.2
Agrawal, B.3
|