메뉴 건너뛰기




Volumn 49, Issue 8, 2011, Pages 1383-1384

Commutability of the ERM-DA470k Reference Material for two assays measuring serum albumin using immunochemical principles

Author keywords

[No Author keywords available]

Indexed keywords

ALBUMIN BLOOD LEVEL; ANALYTIC METHOD; HUMAN; IMMUNOCHEMISTRY; LETTER; MEASUREMENT; NEPHELOMETRY; PRIORITY JOURNAL; QUANTITATIVE ASSAY; REFERENCE VALUE; REGRESSION ANALYSIS; STANDARDIZATION; TURBIDIMETRY;

EID: 80051734718     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/CCLM.2011.619     Document Type: Letter
Times cited : (12)

References (12)
  • 1
    • 17144394483 scopus 로고    scopus 로고
    • Standardization in laboratory medicine: New challenges
    • DOI 10.1016/j.cccn.2004.12.003
    • Panteghini M, Forest JC. Standardization in laboratory medicine: New challenges. Clin Chim Acta 2005;355:1-12. (Pubitemid 40514349)
    • (2005) Clinica Chimica Acta , vol.355 , Issue.1-2 , pp. 1-12
    • Panteghini, M.1    Forest, J.C.2
  • 2
    • 60949093988 scopus 로고    scopus 로고
    • Traceability as a unique tool to improve standardization in laboratory medicine
    • Panteghini M. Traceability as a unique tool to improve standardization in laboratory medicine. Clin Biochem 2009;42: 236-40.
    • (2009) Clin Biochem , vol.42 , pp. 236-40
    • Panteghini, M.1
  • 3
    • 33644770517 scopus 로고    scopus 로고
    • The 'RM family' - Identification of all of its members
    • DOI 10.1007/s00769-005-0046-z
    • Emons H. The 'RM family' -identification of all of its members. Accred Qual Assur 2006;10:690-1. (Pubitemid 43341157)
    • (2006) Accreditation and Quality Assurance , vol.10 , Issue.12 , pp. 690-691
    • Emons, H.1
  • 4
    • 77953201663 scopus 로고    scopus 로고
    • Necessity for high-quality reference materials in the harmonization of laboratory assays
    • Johnson AM. Necessity for high-quality reference materials in the harmonization of laboratory assays. Clin Chem Lab Med 2010;48:747-8.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 747-8
    • Johnson, A.M.1
  • 6
    • 0033788496 scopus 로고    scopus 로고
    • Effect of a new international reference preparation for proteins in human serum (certified reference material 470) on results of the College of American Pathologists survey for plasma proteins
    • Johnson AM, Whicher JT, Ledue TB, Carlström A, Itoh Y, Petersen PH. Effect of a new international reference preparation for proteins in human serum (certified reference material 470) on results of the College of American Pathologists survey for plasma proteins. Arch Pathol Lab Med 2000;124:1496-501.
    • (2000) Arch Pathol Lab Med , vol.124 , pp. 1496-501
    • Johnson, A.M.1    Whicher, J.T.2    Ledue, T.B.3    Carlström, A.4    Itoh, Y.5    Petersen, P.H.6
  • 7
    • 0035213207 scopus 로고    scopus 로고
    • Effect of certified reference material 470 (CRM 470) on national quality assurance programs for serum proteins in Europe
    • DOI 10.1515/CCLM.2001.177
    • Johnson AM, Whicher JT. Effect of certified reference material 470 (CRM 470) on national quality assurance programs for serum proteins in Europe. Clin Chem Lab Med 2001;39: 1123-8. (Pubitemid 33133630)
    • (2001) Clinical Chemistry and Laboratory Medicine , vol.39 , Issue.11 , pp. 1123-1128
    • Johnson, A.M.1    Whicher, J.T.2
  • 8
    • 77953208055 scopus 로고    scopus 로고
    • Development and preparation of a new serum protein reference material: Feasibility studies and processing
    • Zegers I, Schreiber W, Linstead S, Lammers M, McCusker M, Muñoz A, et al. Development and preparation of a new serum protein reference material: Feasibility studies and processing. Clin Chem Lab Med 2010;48:805-13.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 805-13
    • Zegers, I.1    Schreiber, W.2    Linstead, S.3    Lammers, M.4    McCusker, M.5    Munoz, A.6
  • 9
    • 78649819470 scopus 로고    scopus 로고
    • Characterization of the new serum protein reference material ERM-DA470k/IFCC: Value assignment by immunoassay
    • Zegers I, Keller T, Schreiber W, Sheldon J, Albertini R, Blirup-Jensen S, et al. Characterization of the new serum protein reference material ERM-DA470k/IFCC: Value assignment by immunoassay. Clin Chem 2010;56:1880-8.
    • (2010) Clin Chem , vol.56 , pp. 1880-8
    • Zegers, I.1    Keller, T.2    Schreiber, W.3    Sheldon, J.4    Albertini, R.5    Blirup-Jensen, S.6
  • 10
    • 78751626614 scopus 로고    scopus 로고
    • Zegers I on behalf of the IFCC Committee on Plasma Proteins (C-PP) Standardizing plasma protein measurements worldwide: A challenging enterprise
    • Merlini G, Blirup-Jensen S, Myron Johnson A, Sheldon J, Zegers I on behalf of the IFCC Committee on Plasma Proteins (C-PP). Standardizing plasma protein measurements worldwide: A challenging enterprise. Clin Chem Lab Med 2010;48: 1567-75.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 1567-75
    • Merlini, G.1    Blirup-Jensen, S.2    Myron Johnson, A.3    Sheldon, J.4
  • 11
    • 79951727395 scopus 로고    scopus 로고
    • Is the accuracy of serum albumin measurements suitable for clinical application of the test?
    • Infusino I, Braga F, Mozzi R, Valente C, Panteghini M. Is the accuracy of serum albumin measurements suitable for clinical application of the test? Clin Chim Acta 2011;412:791-2.
    • (2011) Clin Chim Acta , vol.412 , pp. 791-2
    • Infusino, I.1    Braga, F.2    Mozzi, R.3    Valente, C.4    Panteghini, M.5
  • 12
    • 80051721874 scopus 로고    scopus 로고
    • CLSI. Characterization and qualification of commutable reference materials for laboratory medicine; Approved guideline. CLSI document C53-A. Wayne PA: Clinical and Laboratory Standards Institute
    • CLSI. Characterization and qualification of commutable reference materials for laboratory medicine; Approved guideline. CLSI document C53-A. Wayne, PA: Clinical and Laboratory Standards Institute, 2010.
    • (2010)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.