메뉴 건너뛰기




Volumn 42, Issue 4-5, 2009, Pages 236-240

Traceability as a unique tool to improve standardization in laboratory medicine

Author keywords

Metrology; Reference laboratories; Standardization; Traceability

Indexed keywords

ALANINE AMINOTRANSFERASE; AMYLASE; ASPARTATE AMINOTRANSFERASE; CREATINE KINASE; CREATININE; GAMMA GLUTAMYLTRANSFERASE; HEMOGLOBIN A1C; LACTATE DEHYDROGENASE; PROSTATE SPECIFIC ANTIGEN;

EID: 60949093988     PISSN: 00099120     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2008.09.098     Document Type: Article
Times cited : (86)

References (26)
  • 1
    • 84929041404 scopus 로고    scopus 로고
    • Örnemark U, Van Nevel L, Smeyers P, Harper C, Taylor PDP. The International Measurement Evaluation Program IMEP-17. Trace and minor constituents in human serum. EUR 20694 EN. Report to participants. Part 2: methodology and quantity specifications. www.imep.ws.
    • Örnemark U, Van Nevel L, Smeyers P, Harper C, Taylor PDP. The International Measurement Evaluation Program IMEP-17. Trace and minor constituents in human serum. EUR 20694 EN. Report to participants. Part 2: methodology and quantity specifications. www.imep.ws.
  • 2
    • 17144394483 scopus 로고    scopus 로고
    • Standardization in laboratory medicine: new challenges
    • Panteghini M., and Forest J.C. Standardization in laboratory medicine: new challenges. Clin. Chim. Acta 355 (2005) 1-12
    • (2005) Clin. Chim. Acta , vol.355 , pp. 1-12
    • Panteghini, M.1    Forest, J.C.2
  • 3
    • 4344648887 scopus 로고    scopus 로고
    • Clinical interpretation of reference intervals and reference limits. A plea for assay harmonization
    • Klee G.G. Clinical interpretation of reference intervals and reference limits. A plea for assay harmonization. Clin. Chem. Lab. Med. 42 (2004) 752-757
    • (2004) Clin. Chem. Lab. Med. , vol.42 , pp. 752-757
    • Klee, G.G.1
  • 4
    • 0029563997 scopus 로고
    • The need for accuracy in Laboratory Medicine
    • Büttner J. The need for accuracy in Laboratory Medicine. Eur. J. Clin. Chem. Clin. Biochem. 33 (1995) 981-988
    • (1995) Eur. J. Clin. Chem. Clin. Biochem. , vol.33 , pp. 981-988
    • Büttner, J.1
  • 5
    • 0242372899 scopus 로고    scopus 로고
    • In vitro diagnostic medical devices - measurement of quantities in biological samples - metrological traceability of values assigned to calibrators and control materials. ISO,
    • ISO 17511:, Geneva, Switzerland
    • ISO 17511:2003. In vitro diagnostic medical devices - measurement of quantities in biological samples - metrological traceability of values assigned to calibrators and control materials. ISO, Geneva, Switzerland.
    • (2003)
  • 6
    • 17144399416 scopus 로고    scopus 로고
    • In vitro diagnostic medical devices - measurement of quantities in biological samples - metrological traceability of values for catalytic concentration of enzymes assigned to calibrators and control materials. ISO,
    • ISO 18153:, Geneva, Switzerland
    • ISO 18153:2003. In vitro diagnostic medical devices - measurement of quantities in biological samples - metrological traceability of values for catalytic concentration of enzymes assigned to calibrators and control materials. ISO, Geneva, Switzerland.
    • (2003)
  • 7
    • 84929041405 scopus 로고    scopus 로고
    • Directive 98/79/EC of the European Parliament and of the Council of 27 October 1998 on in vitro diagnostic medical devices. Official Journal of the European Communities 1998(Dec 7);L331:1-37.
    • Directive 98/79/EC of the European Parliament and of the Council of 27 October 1998 on in vitro diagnostic medical devices. Official Journal of the European Communities 1998(Dec 7);L331:1-37.
  • 8
    • 44349178752 scopus 로고    scopus 로고
    • Traceability, reference systems and result comparability
    • Panteghini M. Traceability, reference systems and result comparability. Clin. Biochem. Rev. 28 (2007) 97-104
    • (2007) Clin. Biochem. Rev. , vol.28 , pp. 97-104
    • Panteghini, M.1
  • 9
    • 0032146055 scopus 로고    scopus 로고
    • Impact of reference materials on accuracy in clinical chemistry
    • Franzini C., and Ceriotti F. Impact of reference materials on accuracy in clinical chemistry. Clin. Biochem. 31 (1998) 449-457
    • (1998) Clin. Biochem. , vol.31 , pp. 449-457
    • Franzini, C.1    Ceriotti, F.2
  • 12
    • 0037212728 scopus 로고    scopus 로고
    • Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes
    • Miller W.G. Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes. Clin. Chim. Acta 327 (2003) 25-37
    • (2003) Clin. Chim. Acta , vol.327 , pp. 25-37
    • Miller, W.G.1
  • 13
    • 33750090092 scopus 로고    scopus 로고
    • The importance of metrological traceability on the validity of creatinine measurement as an index of renal function
    • Panteghini M., Myers G.L., Miller W.G., and Greenberg N. The importance of metrological traceability on the validity of creatinine measurement as an index of renal function. Clin. Chem. Lab. Med. 44 (2006) 1187-1192
    • (2006) Clin. Chem. Lab. Med. , vol.44 , pp. 1187-1192
    • Panteghini, M.1    Myers, G.L.2    Miller, W.G.3    Greenberg, N.4
  • 14
    • 1642525622 scopus 로고    scopus 로고
    • Current concepts in standardization of cardiac marker immunoassays
    • Panteghini M. Current concepts in standardization of cardiac marker immunoassays. Clin. Chem. Lab. Med. 42 (2004) 3-8
    • (2004) Clin. Chem. Lab. Med. , vol.42 , pp. 3-8
    • Panteghini, M.1
  • 15
    • 0035043203 scopus 로고    scopus 로고
    • Immunoassay standardization: is it possible, who is responsible, who is capable?
    • Stenman U.H. Immunoassay standardization: is it possible, who is responsible, who is capable?. Clin. Chem. 47 (2001) 815-820
    • (2001) Clin. Chem. , vol.47 , pp. 815-820
    • Stenman, U.H.1
  • 16
    • 18244404332 scopus 로고    scopus 로고
    • Approved IFCC reference method for the measurement of HbA1c in human blood
    • Jeppsson J.O., Kobold U., Barr J., et al. Approved IFCC reference method for the measurement of HbA1c in human blood. Clin. Chem. Lab. Med. 40 (2002) 78-89
    • (2002) Clin. Chem. Lab. Med. , vol.40 , pp. 78-89
    • Jeppsson, J.O.1    Kobold, U.2    Barr, J.3
  • 17
    • 39749107290 scopus 로고    scopus 로고
    • The IFCC reference measurement system for HbA1c: a 6-year progress report
    • Weykamp C., John W.G., Mosca A., et al. The IFCC reference measurement system for HbA1c: a 6-year progress report. Clin. Chem. 54 (2008) 240-248
    • (2008) Clin. Chem. , vol.54 , pp. 240-248
    • Weykamp, C.1    John, W.G.2    Mosca, A.3
  • 20
    • 2442526439 scopus 로고    scopus 로고
    • Variation in prostate specific antigen results from 2 different assay platforms: clinical impact on 2,304 patients undergoing prostate cancer screening
    • Link R.E., Shariat S.F., Nguyen C.V., et al. Variation in prostate specific antigen results from 2 different assay platforms: clinical impact on 2,304 patients undergoing prostate cancer screening. J. Urol. 171 (2004) 2234-2238
    • (2004) J. Urol. , vol.171 , pp. 2234-2238
    • Link, R.E.1    Shariat, S.F.2    Nguyen, C.V.3
  • 21
    • 9144234059 scopus 로고    scopus 로고
    • IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study
    • Hoelzel W., Weykamp C., Jeppsson J.O., et al. IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study. Clin. Chem. 50 (2004) 166-174
    • (2004) Clin. Chem. , vol.50 , pp. 166-174
    • Hoelzel, W.1    Weykamp, C.2    Jeppsson, J.O.3
  • 22
    • 34548719355 scopus 로고    scopus 로고
    • Implementation of haemoglobin A1c results traceable to the IFCC reference system: the way forward
    • Panteghini M., and John W.G. Implementation of haemoglobin A1c results traceable to the IFCC reference system: the way forward. Clin. Chem. Lab. Med. 45 (2007) 942-944
    • (2007) Clin. Chem. Lab. Med. , vol.45 , pp. 942-944
    • Panteghini, M.1    John, W.G.2
  • 23
    • 4344681290 scopus 로고    scopus 로고
    • Metrological traceability of calibration in the estimation and use of common medical decision-making criteria
    • Thienpont L.M., Van Uytfanghe K., and Rodriguez Cabaleiro D. Metrological traceability of calibration in the estimation and use of common medical decision-making criteria. Clin. Chem. Lab. Med. 42 (2004) 842-850
    • (2004) Clin. Chem. Lab. Med. , vol.42 , pp. 842-850
    • Thienpont, L.M.1    Van Uytfanghe, K.2    Rodriguez Cabaleiro, D.3
  • 24
    • 33746915004 scopus 로고    scopus 로고
    • Trueness verification and traceability assessment of results from commercial systems for measurement of six enzyme activities in serum. An international study in the EC4 framework of the Calibration 2000 project
    • Jansen R., Schumann G., Baadenhuijsen H., et al. Trueness verification and traceability assessment of results from commercial systems for measurement of six enzyme activities in serum. An international study in the EC4 framework of the Calibration 2000 project. Clin. Chim. Acta 368 (2006) 160-167
    • (2006) Clin. Chim. Acta , vol.368 , pp. 160-167
    • Jansen, R.1    Schumann, G.2    Baadenhuijsen, H.3
  • 25
    • 0038129689 scopus 로고    scopus 로고
    • Trueness verification in European external quality assessment schemes: time to care about the quality of samples
    • Thienpont L.M., Stöckl D., Friedecky B., Kratochvila J., and Budina M. Trueness verification in European external quality assessment schemes: time to care about the quality of samples. Scand. J. Clin. Lab. Invest. 63 (2003) 195-202
    • (2003) Scand. J. Clin. Lab. Invest. , vol.63 , pp. 195-202
    • Thienpont, L.M.1    Stöckl, D.2    Friedecky, B.3    Kratochvila, J.4    Budina, M.5
  • 26
    • 44949254207 scopus 로고    scopus 로고
    • Enzymatic assays for creatinine: time for action
    • Panteghini M on behalf of the IFCC Scientific Division
    • Panteghini M on behalf of the IFCC Scientific Division. Enzymatic assays for creatinine: time for action. Clin. Chem. Lab. Med. 46 (2008) 567-572
    • (2008) Clin. Chem. Lab. Med. , vol.46 , pp. 567-572


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.