Volumn 50, Issue 16, 2011, Pages 9539-9549

Mechanism and in vitro release kinetic study of sirolimus from a biodegradable polymeric matrix coated cardiovascular stent

Author keywords

[No Author keywords available]

Indexed keywords

ADVERSE EVENTS; BIOLOGICAL FLUIDS; CARDIOVASCULAR STENTS; DRUG DELIVERY VEHICLES; DRUG DISSOLUTION; DRUG ELUTION; DRUG RELEASE; DRUG RELEASE KINETICS; DRUG RELEASE MECHANISM; DRUG-ELUTING STENTS; HUMAN HEALTH; IN-VITRO; INFLAMMATORY REACTION; KINETIC STUDY; MEDICINAL APPLICATIONS; METALLIC STENTS; MULTIPLE LAYERS; POLY VINYL PYRROLIDONE; POLYMERIC MATRICES; PROTECTIVE LAYERS; SIROLIMUS; THERAPEUTIC DRUGS; TOP-COATS;

EID: 80051724261     PISSN: 08885885     EISSN: 15205045     Source Type: Journal    
DOI: 10.1021/ie102163z     Document Type: Article
Times cited : (60)

References (34)
  • 3
    • 0035210072 scopus 로고    scopus 로고
    • Mechanisms of angioplasty and stent restenosis: Implications for design of rational therapy
    • DOI 10.1016/S0163-7258(01)00153-X, PII S016372580100153X
    • Bennett, M. R.; OSullivan, M. Mechanisms of angioplasty and stent restenosis: implications for design of rational therapy Pharmacol. Ther. 2001, 91, 149-166 (Pubitemid 33139799)
    • (2001) Pharmacology and Therapeutics , vol.91 , Issue.2 , pp. 149-166
    • Bennett, M.R.1    O'Sullivan, M.2
  • 5
    • 0029966552 scopus 로고
    • Interaction of human cytomegalovirus with p53: Possible role in coronary restenosis
    • Spier, E.; Huang, E. S.; Modali, R. Interaction of human cytomegalovirus with p53: possible role in coronary restenosis Scand. J. Infect. Dis., Suppl. 1995, 99, 78-91
    • (1995) Scand. J. Infect. Dis., Suppl. , vol.99 , pp. 78-91
    • Spier, E.1    Huang, E.S.2    Modali, R.3
  • 6
    • 0037303289 scopus 로고    scopus 로고
    • In-stent stenosis: Pathology and implications for the development of drug eluting stents
    • Bennett, M. R. In-Stent Stenosis: Pathology and Implications for the Development of Drug Eluting Stents Heart 2003, 89, 218-224 (Pubitemid 36115115)
    • (2003) Heart , vol.89 , Issue.2 , pp. 218-224
    • Bennett, M.R.1
  • 10
    • 0028876806 scopus 로고
    • Rapamycin-FKBP Inhibits Cell Cycle Regulators of Proliferation in Vascular Smooth Muscle Cells
    • Marx, S. O.; Jayaraman, T.; Go, L. O.; Marks, A. R. Rapamycin-FKBP Inhibits Cell Cycle Regulators of Proliferation in Vascular Smooth Muscle Cells Circ. Res. 1995, 76, 412-417
    • (1995) Circ. Res. , vol.76 , pp. 412-417
    • Marx, S.O.1    Jayaraman, T.2    Go, L.O.3    Marks, A.R.4
  • 11
    • 0029845013 scopus 로고    scopus 로고
    • Rapamycin inhibits vascular smooth muscle cell migration
    • Poon., M.; Marx, S. O.; Gallo, R. Rapamycin inhibits vascular smooth muscle cell migration J. Clin. Invest. 1996, 98, 2777-2783
    • (1996) J. Clin. Invest. , vol.98 , pp. 2777-2783
    • Poon, M.1    Marx, S.O.2    Gallo, R.3
  • 12
    • 0031834020 scopus 로고    scopus 로고
    • High local production of nitric oxide as a possible mechanism by which rapamycin prevents transplant arteriosclerosis
    • DOI 10.1016/S0041-1345(98)00107-9, PII S0041134598001079
    • Pham, S. M.; Shears, L. L.; Kawaharda, N. High local production of nitric oxide as a possible mechanism by which rapamycin prevents transplant arteriosclerosis Transplant. Proc. 1998, 30, 953-954 (Pubitemid 28309437)
    • (1998) Transplantation Proceedings , vol.30 , Issue.4 , pp. 953-954
    • Pham, S.M.1    Shears, L.L.2    Kawaharada, N.3    Li, S.4    Venkataramanan, R.5    Sehgal, S.6
  • 14
    • 0028909630 scopus 로고
    • Treatment with rapamycin and mycophenolic acid reduces arterial intimal thickening produced by mechanical injury and allows endothelial replacement
    • Gregory, C. R.; Huang, X.; Pratt, R. E. Treatment with rapamycin and mycophenolic acid reduces arterial intimal thickening produced by mechanical injury and allows endothelial replacement Transplantation 1995, 59, 655-661
    • (1995) Transplantation , vol.59 , pp. 655-661
    • Gregory, C.R.1    Huang, X.2    Pratt, R.E.3
  • 16
    • 33744537149 scopus 로고    scopus 로고
    • Mechanisms of controlled drug release from drug-eluting stents
    • DOI 10.1016/j.addr.2006.01.016, PII S0169409X06000275
    • Acharya, G.; Park, K. Mechanisms of controlled drug release from drug-eluting stents Adv. Drug Delivery Rev. 2006, 58, 387-401 (Pubitemid 43816741)
    • (2006) Advanced Drug Delivery Reviews , vol.58 , Issue.3 , pp. 387-401
    • Acharya, G.1    Park, K.2
  • 19
    • 84994930476 scopus 로고    scopus 로고
    • Degradable polymers for site-specific drug delivery
    • Domb, A.; Amselem, S.; Shah, J.; Maniar, M. Degradable polymers for site-specific drug delivery Polym. Adv. Technol. 2003, 3 (6) 279-292
    • (2003) Polym. Adv. Technol. , vol.3 , Issue.6 , pp. 279-292
    • Domb, A.1    Amselem, S.2    Shah, J.3    Maniar, M.4
  • 20
    • 33746859774 scopus 로고    scopus 로고
    • Angiographic results of the first human experience with the Biolimus A9 drug-eluting stent for de novo coronary lesions
    • Costa, R. A.; Lansky, A. J.; Abizaid, A.; Müeller, R.; Tsuchiya, Y.; Mori, K. Angiographic results of the first human experience with the Biolimus A9 drug-eluting stent for de novo coronary lesions Am. J. Cardiol. 2006, 98, 443-436
    • (2006) Am. J. Cardiol. , vol.98 , pp. 443-436
    • Costa, R.A.1    Lansky, A.J.2    Abizaid, A.3    Müeller, R.4    Tsuchiya, Y.5    Mori, K.6
  • 21
    • 73949089126 scopus 로고    scopus 로고
    • Randomized, non-inferiority trial of three limus agent-eluting stents with different polymer coatings: The Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus- Eluting Stents (ISAR-TEST-4) Trial
    • Byrne, R. A.; Kastrati, A.; Kufner, S. Randomized, non-inferiority trial of three limus agent-eluting stents with different polymer coatings: The Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus- Eluting Stents (ISAR-TEST-4) Trial Eur. Heart J. 2009, 30 (20) 2441-2449
    • (2009) Eur. Heart J. , vol.30 , Issue.20 , pp. 2441-2449
    • Byrne, R.A.1    Kastrati, A.2    Kufner, S.3
  • 23
    • 14344271133 scopus 로고    scopus 로고
    • Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: A quantitative coronary angiography and three-dimensional intravascular ultrasound study
    • Sousa, J. E.; Costa, M. A.; Abizaid, A.; Abizaid, A. S.; Feres, F.; Pinto, I. M. F.; Seixas, A. C.; Staico, R.; Mattos, L. A.; Sousa, A. G. M. R.; Falotico, R.; Jaeger, J.; Popma, J. J.; Serruys, P. W. Lack of Neointimal Proliferation After Implantation of Sirolimus-Coated Stents in Human Coronary Arteries A Quantitative Coronary Angiography and Three-Dimensional Intravascular Ultrasound Study Circulation 2001, 103, 192-195 (Pubitemid 32095401)
    • (2001) Circulation , vol.103 , Issue.2 , pp. 192-195
    • Sousa, J.E.1    Costa, M.A.2    Abizaid, A.3    Abizaid, A.S.4    Feres, F.5    Pinto, I.M.F.6    Seixas, A.C.7    Staico, R.8    Mattos, L.A.9    Sousa, A.G.M.R.10    Falotico, R.11    Jaeger, J.12    Popma, J.J.13    Serruys, P.W.14
  • 24
    • 64749115811 scopus 로고    scopus 로고
    • Lowering the Dose of Sirolimus, Released from a Nonpolymeric Hydroxyapatite Coated Coronary Stent, Reduces Signs of Delayed Healing
    • Van Der Giessen, W. J.; Sorop, O.; Serruys, P. W.; Peters-Krabbendam, I.; Van Beusekom, H. M. M. Lowering the Dose of Sirolimus, Released From a Nonpolymeric Hydroxyapatite Coated Coronary Stent, Reduces Signs of Delayed Healing J. Am. Coll. Cardiol. Intv. 2009, 2, 284-290
    • (2009) J. Am. Coll. Cardiol. Intv. , vol.2 , pp. 284-290
    • Van Der Giessen, W.J.1    Sorop, O.2    Serruys, P.W.3    Peters-Krabbendam, I.4    Van Beusekom, H.M.M.5
  • 25
    • 35248880518 scopus 로고    scopus 로고
    • Intravascular drug release kinetics dictate arterial drug deposition, retention, and distribution
    • DOI 10.1016/j.jconrel.2007.06.025, PII S016836590700315X
    • Balakrishnan, B.; Dooley, J. F.; Kopia, G.; Edelman, E. R. Intravascular drug release kinetics dictate arterial drug deposition, retention, and distribution J. Controlled Release 2007, 123, 100-108 (Pubitemid 47562135)
    • (2007) Journal of Controlled Release , vol.123 , Issue.2 , pp. 100-108
    • Balakrishnan, B.1    Dooley, J.F.2    Kopia, G.3    Edelman, E.R.4
  • 26
    • 73049134701 scopus 로고
    • Rate of release of medicaments from ointment bases containing drugs in suspension
    • Higuchi, T. Rate of release of medicaments from ointment bases containing drugs in suspension J. Pharm. Sci. 1961, 50, 874-875
    • (1961) J. Pharm. Sci. , vol.50 , pp. 874-875
    • Higuchi, T.1
  • 27
    • 0020539240 scopus 로고
    • Mechanisms of solute release from porous hydrophilic polymers
    • DOI 10.1016/0378-5173(83)90064-9
    • Korsmeyer, R. W.; Gurny, R.; Doelker, E. M.; Buri, P.; Peppas, N. A. Mechanism of solute release from porous hydrophilic polymers Int. J. Pharm. 1983, 15, 25-35 (Pubitemid 13092121)
    • (1983) International Journal of Pharmaceutics , vol.15 , Issue.1 , pp. 25-35
    • Korsmeyer, R.W.1    Gurny, R.2    Doelker, E.3
  • 28
    • 0021904208 scopus 로고
    • Analysis of Fickian and non-Fickian drug release from polymers
    • Peppas, N. A. Analysis of Fickian and non-Fickian drug release from polymers Pharm. Acta Helv. 1985, 60, 110-111
    • (1985) Pharm. Acta Helv. , vol.60 , pp. 110-111
    • Peppas, N.A.1
  • 30
    • 78149412576 scopus 로고    scopus 로고
    • Dexamethasone eluting biodegradable polymeric matrix coated stent for intravascular drug delivery
    • doi: 10.1016/j.cherd.2010.03.007
    • Raval, A.; Parikh, J.; Engineer, C. Dexamethasone eluting biodegradable polymeric matrix coated stent for intravascular drug delivery. Chem. Eng. Res. Des. 2010, doi: 10.1016/j.cherd.2010.03.007
    • (2010) Chem. Eng. Res. Des.
    • Raval, A.1    Parikh, J.2    Engineer, C.3
  • 32
    • 77956220813 scopus 로고    scopus 로고
    • Mechanism of controlled release kinetics from medical devices
    • Raval, A. J.; Parikh, J. Engineer, C. Mechanism of controlled release kinetics from medical devices Braz. J. Chem. Eng. 2010, 27 (2) 211-225
    • (2010) Braz. J. Chem. Eng. , vol.27 , Issue.2 , pp. 211-225
    • Raval, A.J.1    Parikh, J.2    Engineer, C.3
  • 33
    • 77956197551 scopus 로고    scopus 로고
    • Novel biodegradable polymeric matrix coated cardiovascular stent for controlled drug delivery
    • Raval, A.; Choubey, A. Engineer, C.; Kotadia, H.; Kothwala, D. Novel biodegradable polymeric matrix coated cardiovascular stent for controlled drug delivery. Trends Biomater Artif. Organs 2007, Vol 20 (2) 101-110
    • (2007) Trends Biomater Artif. Organs , vol.20 , Issue.2 , pp. 101-110
    • Raval, A.1    Choubey, A.2    Engineer, C.3    Kotadia, H.4    Kothwala, D.5
  • 34
    • 2342652446 scopus 로고    scopus 로고
    • Mathematical Comparison of Dissolution Profiles
    • Moore, J. W.; Flanner, H. H. Mathematical comparison of dissolution profiles Pharm. Technol. 1996, 20, 64-74 (Pubitemid 126450495)
    • (1996) Pharmaceutical Technology , vol.20 , Issue.6 , pp. 64-74
    • Moore, J.W.1    Flanner, H.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.