Volumn 66, Issue 3, 2011, Pages 669-677

Identification of signal bias in the variable flip angle method by linear display of the algebraic ernst equation

Author keywords

Ernst equation; quantification; variable flip angle experiment

Indexed keywords

DATA ACQUISITION; MATHEMATICAL TRANSFORMATIONS; RELAXATION TIME;

EID: 80051689849     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22849     Document Type: Article
Times cited : (32)

References (31)
  • 3
    • 60349117378 scopus 로고    scopus 로고
    • Increased SNR and reduced distortions by averaging multiple gradient echo signals in 3D FLASH imaging of the human brain at 3T
    • Helms G, Dechent P,. Increased SNR and reduced distortions by averaging multiple gradient echo signals in 3D FLASH imaging of the human brain at 3T. J Magn Reson Imaging 2009; 29: 198-204.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 198-204
    • Helms, G.1    Dechent, P.2
  • 4
    • 33847803187 scopus 로고
    • Optimal determination of relaxation times of Fourier transform nuclear magnetic resonance. Determination of spin-lattice relaxation times in chemically polarized species
    • Christensen KA, Grant DM, Schulman EM, Walling C,. Optimal determination of relaxation times of Fourier transform nuclear magnetic resonance. Determination of spin-lattice relaxation times in chemically polarized species. J Phys Chem 1974; 78: 1971-1977.
    • (1974) J Phys Chem , vol.78 , pp. 1971-1977
    • Christensen, K.A.1    Grant, D.M.2    Schulman, E.M.3    Walling, C.4
  • 5
    • 0010930613 scopus 로고
    • A new look at the method of variable nutation angle for the measurement of spin-lattice relaxation time using Fourier transform NMR
    • Gupta RK,. A new look at the method of variable nutation angle for the measurement of spin-lattice relaxation time using Fourier transform NMR. J Magn Reson 1977; 25: 231-235.
    • (1977) J Magn Reson , vol.25 , pp. 231-235
    • Gupta, R.K.1
  • 6
    • 0013367398 scopus 로고
    • Driven-equilibrium single pulse observation of T1 relaxation. A re-evaluation of a rapid 'new' method for determining NMR spin-lattice relaxation times
    • Homer J, Beevers MS,. Driven-equilibrium single pulse observation of T1 relaxation. A re-evaluation of a rapid 'new' method for determining NMR spin-lattice relaxation times. J Magn Reson 1985; 63: 287-297.
    • (1985) J Magn Reson , vol.63 , pp. 287-297
    • Homer, J.1    Beevers, M.S.2
  • 7
    • 0023635199 scopus 로고
    • Optimizing the precision in T1 relaxation estimation using limited flip angles
    • DOI 10.1002/mrm.1910050502
    • Wang HZ, Riederer SJ, Lee JN,. Optimizing the precision in T1 relaxation estimation using limited flip angles. Magn Reson Med 1987; 5: 399-416. (Pubitemid 17167630)
    • (1987) Magnetic Resonance in Medicine , vol.5 , Issue.5 , pp. 399-416
    • Wang, H.Z.1    Riederer, S.J.2    Lee, J.N.3
  • 8
    • 0345742631 scopus 로고    scopus 로고
    • 2, Relaxation Times Measurement
    • DOI 10.1002/mrm.10661
    • Deoni SC, Peters TM, Rutt BK,. Determination of optimal angles for variable nutation proton magnetic spin-lattice, T1, and spin-spin, T2, relaxation times measurement. Magn Res Med 2004; 51: 194-199. (Pubitemid 38095718)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.1 , pp. 194-199
    • Deoni, S.C.L.1    Peters, T.M.2    Rutt, B.K.3
  • 9
    • 0037370514 scopus 로고    scopus 로고
    • 2 mapping using gradient recalled acquisition in the steady state
    • DOI 10.1002/mrm.10407
    • Deoni SCL, Rutt BK, Peters TM,. Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state. Magn Reson Med 2003; 49: 515-526. (Pubitemid 36262820)
    • (2003) Magnetic Resonance in Medicine , vol.49 , Issue.3 , pp. 515-526
    • Deoni, S.C.L.1    Rutt, B.K.2    Peters, T.M.3
  • 10
    • 49049119048 scopus 로고    scopus 로고
    • Linear least-squares method for unbiased estimation of T1 from SPGR signals
    • Chang L-C, Koay CG, Basser PJ, Pierpaoli C,. Linear least-squares method for unbiased estimation of T1 from SPGR signals. Magn Res Med 2008; 60: 496-501.
    • (2008) Magn Res Med , vol.60 , pp. 496-501
    • Chang, L.-C.1    Koay, C.G.2    Basser, P.J.3    Pierpaoli, C.4
  • 11
    • 67650077674 scopus 로고    scopus 로고
    • T1 mapping using spoiled FLASH-EPI hybrid sequences and varying flip angles
    • Preibisch C, Deichmann R,. T1 mapping using spoiled FLASH-EPI hybrid sequences and varying flip angles. Magn Res Med 2009; 62: 240-246.
    • (2009) Magn Res Med , vol.62 , pp. 240-246
    • Preibisch, C.1    Deichmann, R.2
  • 12
    • 77955291857 scopus 로고    scopus 로고
    • Concatenated and parallel optimization for the estimation of T1 map in FLASH MRI with multiple flip angles
    • Wang D, Shi L, Wang Y, Yuan J, Yeung D, King A, Ahuja A, Heng P,. Concatenated and parallel optimization for the estimation of T1 map in FLASH MRI with multiple flip angles. Magn Reson Med 2010; 63: 1431-1436.
    • (2010) Magn Reson Med , vol.63 , pp. 1431-1436
    • Wang, D.1    Shi, L.2    Wang, Y.3    Yuan, J.4    Yeung, D.5    King, A.6    Ahuja, A.7    Heng, P.8
  • 13
    • 33644813235 scopus 로고    scopus 로고
    • 1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity
    • DOI 10.1002/mrm.20791
    • Cheng H-LM, Wright GA,. Rapid high-resolution T1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity. Magn Res Med 2006; 55: 566-574. (Pubitemid 43352555)
    • (2006) Magnetic Resonance in Medicine , vol.55 , Issue.3 , pp. 566-574
    • Cheng, H.-L.M.1    Wright, G.A.2
  • 14
    • 60349123561 scopus 로고    scopus 로고
    • Influence of RF spoiling on the stability and accuracy of T1 mapping based on spoiled FLASH with varying flip angles
    • Preibisch C, Deichmann R,. Influence of RF spoiling on the stability and accuracy of T1 mapping based on spoiled FLASH with varying flip angles. Magn Res Med 2009; 61: 125-135.
    • (2009) Magn Res Med , vol.61 , pp. 125-135
    • Preibisch, C.1    Deichmann, R.2
  • 15
    • 77952705528 scopus 로고    scopus 로고
    • Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady-state techniques
    • Yarnykh VL,. Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady-state techniques. Magn Reson Med 2010; 63: 1610-1626.
    • (2010) Magn Reson Med , vol.63 , pp. 1610-1626
    • Yarnykh, V.L.1
  • 16
    • 78049425927 scopus 로고    scopus 로고
    • Exact algebraization of the Ernst equation for spoiled gradient echo MRI
    • Dathe H, Helms G,. Exact algebraization of the Ernst equation for spoiled gradient echo MRI. Phys Med Biol 2010; 55: 4231-4245.
    • (2010) Phys Med Biol , vol.55 , pp. 4231-4245
    • Dathe, H.1    Helms, G.2
  • 17
    • 40449133227 scopus 로고    scopus 로고
    • Quantitative FLASH MRI at 3T using a rational approximation of the Ernst equation
    • Helms G, Dathe H, Dechent P,. Quantitative FLASH MRI at 3T using a rational approximation of the Ernst equation. Magn Res Med 2008; 59: 1196-1203.
    • (2008) Magn Res Med , vol.59 , pp. 1196-1203
    • Helms, G.1    Dathe, H.2    Dechent, P.3
  • 18
    • 57149103503 scopus 로고    scopus 로고
    • High-resolution maps of magnetisation transfer with inherent correction for RF inhomogeneity and T1 relaxation obtained from 3D FLASH MRI
    • Erratum in: Magn Reson Med 2010;64:1856
    • Helms G, Dathe H, Kallenberg K, Dechent P,. High-resolution maps of magnetisation transfer with inherent correction for RF inhomogeneity and T1 relaxation obtained from 3D FLASH MRI. Magn Reson Med 2008; 60: 1396-1407; Erratum in: Magn Reson Med 2010;64:1856.
    • (2008) Magn Reson Med , vol.60 , pp. 1396-1407
    • Helms, G.1    Dathe, H.2    Kallenberg, K.3    Dechent, P.4
  • 19
    • 77953918713 scopus 로고    scopus 로고
    • Optimization and validation of methods for mapping of the radiofrequency transmit field at 3T
    • Lutti A, Hutton C, Finsterbusch J, Helms G, Weiskopf N,. Optimization and validation of methods for mapping of the radiofrequency transmit field at 3T. Magn Reson Med 2010; 64: 229-238.
    • (2010) Magn Reson Med , vol.64 , pp. 229-238
    • Lutti, A.1    Hutton, C.2    Finsterbusch, J.3    Helms, G.4    Weiskopf, N.5
  • 21
    • 78650194424 scopus 로고    scopus 로고
    • Unified segmentation based correction of R1 brain maps for RF transmit field inhomogeneities (UNICORT)
    • Weiskopf N, Lutti A, Helms G, Novak M, Ashburner J, Hutton C,. Unified segmentation based correction of R1 brain maps for RF transmit field inhomogeneities (UNICORT). NeuroImage 2011; 54 (3): 2116-24.
    • (2011) NeuroImage , vol.54 , Issue.3 , pp. 2116-2124
    • Weiskopf, N.1    Lutti, A.2    Helms, G.3    Novak, M.4    Ashburner, J.5    Hutton, C.6
  • 22
    • 0035036729 scopus 로고    scopus 로고
    • 1 measurement in the presence of non-ideal RF pulse shape and RF field nonuniformity
    • DOI 10.1002/mrm.1112
    • Parker GL, Barker GJ, Tofts PA,. Accurate multislice gradient echo T(1) measurement in the presence of non-ideal RF pulse shape and RF field nonuniformity. Magn Reson Med 2001; 45: 838-845. (Pubitemid 32402026)
    • (2001) Magnetic Resonance in Medicine , vol.45 , Issue.5 , pp. 838-845
    • Parker, G.J.M.1    Barker, G.J.2    Tofts, P.S.3
  • 23
    • 46749117933 scopus 로고    scopus 로고
    • The principles of quantification applied to in vivo proton MR spectroscopy
    • Helms G,. The principles of quantification applied to in vivo proton MR spectroscopy. Eur J Radiol 2008; 67: 218-229.
    • (2008) Eur J Radiol , vol.67 , pp. 218-229
    • Helms, G.1
  • 24
    • 67349261098 scopus 로고    scopus 로고
    • Improved segmentation of deep brain grey matter structures using magnetization transfer (MT) parameter maps
    • Helms G, Draganski B, Frackowiak R, Ashburner J, Weiskopf N,. Improved segmentation of deep brain grey matter structures using magnetization transfer (MT) parameter maps. NeuroImage 2009; 47: 194-198.
    • (2009) NeuroImage , vol.47 , pp. 194-198
    • Helms, G.1    Draganski, B.2    Frackowiak, R.3    Ashburner, J.4    Weiskopf, N.5
  • 25
    • 57149103503 scopus 로고    scopus 로고
    • High-resolution maps of magnetisation transfer with inherent correction for RF inhomogeneity and T1 relaxation obtained from 3D FLASH MRI
    • Helms G, Dathe H, Kallenberg K, Dechent P,. High-resolution maps of magnetisation transfer with inherent correction for RF inhomogeneity and T1 relaxation obtained from 3D FLASH MRI. Magn Res Med 2008; 60: 1396-1407.
    • (2008) Magn Res Med , vol.60 , pp. 1396-1407
    • Helms, G.1    Dathe, H.2    Kallenberg, K.3    Dechent, P.4
  • 26
    • 51449114690 scopus 로고    scopus 로고
    • Rapid radiofrequency field mapping in vivo using single-shot STEAM MRI
    • Helms G, Finsterbusch J, Weiskopf N, Dechent P,. Rapid radiofrequency field mapping in vivo using single-shot STEAM MRI. Magn Reson Med 2008; 60: 739-743.
    • (2008) Magn Reson Med , vol.60 , pp. 739-743
    • Helms, G.1    Finsterbusch, J.2    Weiskopf, N.3    Dechent, P.4
  • 27
    • 73749088328 scopus 로고    scopus 로고
    • A fast B1-mapping method for the correction and normalization of magnetization transfer ratio maps at 3 T
    • Volz S, Nöth U, Rotarska-Jagiela A, Deichmann R,. A fast B1-mapping method for the correction and normalization of magnetization transfer ratio maps at 3 T. NeuroImage 2010; 9: 3015-3026.
    • (2010) NeuroImage , vol.9 , pp. 3015-3026
    • Volz, S.1    Nöth, U.2    Rotarska-Jagiela, A.3    Deichmann, R.4
  • 28
    • 33846078031 scopus 로고    scopus 로고
    • Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field
    • DOI 10.1002/mrm.21120
    • Yarnykh V,. Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magn Reson Med 2007; 57: 192-200. (Pubitemid 46067949)
    • (2007) Magnetic Resonance in Medicine , vol.57 , Issue.1 , pp. 192-200
    • Yarnykh, V.L.1
  • 30
    • 77955927715 scopus 로고    scopus 로고
    • Effects of in-pulse transverse relaxation in 3D ultrashort echo time sequences: Analytical derivation, comparison to numerical simulation and experimental application at 3T
    • Springer F, Steidle G, Martirosian P, Claussen CD, Schick F,. Effects of in-pulse transverse relaxation in 3D ultrashort echo time sequences: Analytical derivation, comparison to numerical simulation and experimental application at 3T. J Magn Reson 2010; 206: 88-96.
    • (2010) J Magn Reson , vol.206 , pp. 88-96
    • Springer, F.1    Steidle, G.2    Martirosian, P.3    Claussen, C.D.4    Schick, F.5
  • 31
    • 34548526142 scopus 로고    scopus 로고
    • 1 and ρ magnetic resonance imaging at 3 Tesla
    • DOI 10.1016/j.neuroimage.2007.06.036, PII S1053811907005721
    • Deoni SC, Catani M,. Visualization of the deep cerebellar nuclei using quantitative T1 and rho magnetic resonance imaging at 3 Tesla NeuroImage 2007; 37: 1260-1266. (Pubitemid 47385289)
    • (2007) NeuroImage , vol.37 , Issue.4 , pp. 1260-1266
    • Deoni, S.C.L.1    Catani, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.