메뉴 건너뛰기




Volumn 42, Issue 3, 2011, Pages 324-331

Reliability of semiautomatic centerline analysis versus manual aortic measurement techniques for TEVAR among Non-experts

Author keywords

Computed tomography; Computer assisted image analysis; Endovascular; Thoracic aorta; Three dimensional imaging

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPARATIVE EFFECTIVENESS; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC TEST ACCURACY STUDY; ENDOVASCULAR ANEURYSM REPAIR; FEMALE; HUMAN; MALE; MANUAL AXIAL SLICE; MANUAL MULTIPLANAR REFORMATION; MEASUREMENT; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; RELIABILITY; RETROSPECTIVE STUDY; SEMIAUTOMATIC CENTERLINE ANALYSIS; SUBCLAVIAN ARTERY; THORACIC AORTA; THORACIC AORTA ANEURYSM;

EID: 80051670270     PISSN: 10785884     EISSN: 15322165     Source Type: Journal    
DOI: 10.1016/j.ejvs.2011.04.019     Document Type: Article
Times cited : (30)

References (26)
  • 2
    • 71649094310 scopus 로고    scopus 로고
    • Intramural hematoma and penetrating ulcers: Indications to endovascular treatment
    • H. Eggebrecht, B. Plicht, P. Kahlert, and R. Erbel Intramural hematoma and penetrating ulcers: indications to endovascular treatment Eur J Vasc Endovasc Surg 38 2009 659 665
    • (2009) Eur J Vasc Endovasc Surg , vol.38 , pp. 659-665
    • Eggebrecht, H.1    Plicht, B.2    Kahlert, P.3    Erbel, R.4
  • 5
    • 60749115577 scopus 로고    scopus 로고
    • Imaging of the thoracic aorta before and after stent-graft repair of aneurysms and dissections
    • T. Ueda, D. Fleischmann, G.D. Rubin, M.D. Dake, and D.Y. Sze Imaging of the thoracic aorta before and after stent-graft repair of aneurysms and dissections Semin Thorac Cardiovasc Surg 20 2008 348 357
    • (2008) Semin Thorac Cardiovasc Surg , vol.20 , pp. 348-357
    • Ueda, T.1    Fleischmann, D.2    Rubin, G.D.3    Dake, M.D.4    Sze, D.Y.5
  • 8
    • 34249025208 scopus 로고    scopus 로고
    • Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair
    • DOI 10.1148/radiol.2433051649
    • S.W. Stavropoulos, and S.R. Charagundla Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair Radiology 243 2007 641 655 (Pubitemid 46799417)
    • (2007) Radiology , vol.243 , Issue.3 , pp. 641-655
    • Stavropoulos, S.W.1    Charagundla, S.R.2
  • 9
    • 77349120304 scopus 로고    scopus 로고
    • Endovascular aortic repair versus open surgical repair for descending thoracic aortic disease a systematic review and meta-analysis of comparative studies
    • D. Cheng, J. Martin, H. Shennib, J. Dunning, C. Muneretto, and S. Schueler Endovascular aortic repair versus open surgical repair for descending thoracic aortic disease a systematic review and meta-analysis of comparative studies J Am Coll Cardiol 55 2010 986 1001
    • (2010) J Am Coll Cardiol , vol.55 , pp. 986-1001
    • Cheng, D.1    Martin, J.2    Shennib, H.3    Dunning, J.4    Muneretto, C.5    Schueler, S.6
  • 13
    • 0038392904 scopus 로고    scopus 로고
    • Intra- and interobserver variability in the measurements of abdominal aortic and common iliac artery diameter with computed tomography. The Tromsø study
    • DOI 10.1053/ejvs.2002.1856
    • K. Singh, B.K. Jacobsen, S. Solberg, K.H. Bønaa, S. Kumar, and R. Bajic Intra- and interobserver variability in the measurements of abdominal aortic and common iliac artery diameter with computed tomography. The Tromsø study Eur J Vasc Endovasc Surg 25 2003 399 407 (Pubitemid 36592458)
    • (2003) European Journal of Vascular and Endovascular Surgery , vol.25 , Issue.5 , pp. 399-407
    • Singh, K.1    Jacobsen, B.K.2    Solberg, S.3    Bonaa, K.H.4    Kumar, S.5    Bajic, R.6    Arnesen, E.7
  • 14
    • 28344453174 scopus 로고    scopus 로고
    • Automated software supported versus manual aorto-iliac diameter measurements in CT angiography of patients with abdominal aortic aneurysms: Assessment of inter- and intraobserver variation
    • DOI 10.1024/0301-1526.34.4.255
    • N. Diehm, I. Baumgartner, A. Silvestro, P. Herrmann, J. Triller, and J. Schmidli Automated software supported versus manual aorto-iliac diameter measurements in CT angiography of patients with abdominal aortic aneurysms: assessment of inter- and intraobserver variation Vasa 34 2005 255 261 (Pubitemid 41719863)
    • (2005) Vasa - Journal of Vascular Diseases , vol.34 , Issue.4 , pp. 255-261
    • Diehm, N.1    Baumgartner, I.2    Silvestro, A.3    Hermann, P.4    Triller, J.5    Schmidli, J.6    Do, D.D.7    Dinkel, H.-P.8
  • 15
    • 0034925411 scopus 로고    scopus 로고
    • Prediction of aortoiliac stent-graft length: Comparison of measurement methods
    • M. Tillich, B.B. Hill, D.S. Paik, K. Petz, S. Napel, and C.K. Zarins Prediction of aortoiliac stent-graft length: comparison of measurement methods Radiology 220 2001 475 483 (Pubitemid 32667189)
    • (2001) Radiology , vol.220 , Issue.2 , pp. 475-483
    • Tillich, M.1    Hill, B.B.2    Paik, D.S.3    Petz, K.4    Napel, S.5    Zarins, C.K.6    Rubin, G.D.7
  • 16
    • 3042704730 scopus 로고    scopus 로고
    • Computed tomography assessment of thoracic aortic pathology
    • DOI 10.1053/j.semvascsurg.2004.03.005, PII S0895796704000201
    • R.K. Greenberg, J.L. Secor, and T. Painter Computed tomography assessment of thoracic aortic pathology Semin Vasc Surg 17 2004 166 172 (Pubitemid 38858152)
    • (2004) Seminars in Vascular Surgery , vol.17 , Issue.2 , pp. 166-172
    • Greenberg, R.K.1    Secor, J.L.2    Painter, T.3
  • 17
    • 76849110255 scopus 로고    scopus 로고
    • Thoracic aortic aneurysm clinically pertinent controversies and uncertainties
    • J.A. Elefteriades, and E.A. Farkas Thoracic aortic aneurysm clinically pertinent controversies and uncertainties J Am Coll Cardiol 55 2010 841 857
    • (2010) J Am Coll Cardiol , vol.55 , pp. 841-857
    • Elefteriades, J.A.1    Farkas, E.A.2
  • 19
    • 1642294566 scopus 로고    scopus 로고
    • New Vessel Analysis Tool for Morphometric Quantification and Visualization of Vessels in CT and MR Imaging Data Sets
    • T. Boskamp, D. Rinck, F. Link, B. Kümmerlen, G. Stamm, and P. Mildenberger New vessel analysis tool for morphometric quantification and visualization of vessels in CT and MR imaging data sets Radiographics 24 2004 287 297 (Pubitemid 38134612)
    • (2004) Radiographics , vol.24 , Issue.1 , pp. 287-297
    • Boskamp, T.1    Rinck, D.2    Link, F.3    Kummerlen, B.4    Stamm, G.5    Mildenberger, P.6
  • 20
    • 1642347110 scopus 로고    scopus 로고
    • Assessment of Automatic Vessel Tracking Techniques in Preoperative Planning of Transluminal Aortic Stent Graft Implantation
    • DOI 10.1097/00004728-200403000-00020
    • D.T. Boll, J.S. Lewin, J.L. Duerk, D. Smith, K. Subramanyan, and E.M. Merkle Assessment of automatic vessel tracking techniques in preoperative planning of transluminal aortic stent graft implantation J Comput Assist Tomogr 28 2004 278 285 (Pubitemid 38364996)
    • (2004) Journal of Computer Assisted Tomography , vol.28 , Issue.2 , pp. 278-285
    • Boll, D.T.1    Lewin, J.S.2    Duerk, J.L.3    Smith, D.4    Subramanyan, K.5    Merkle, E.M.6
  • 21
    • 61449173907 scopus 로고    scopus 로고
    • Three-dimensional blood vessel quantification via centerline deformation
    • D. Kang, D.C. Suh, and J.B. Ra Three-dimensional blood vessel quantification via centerline deformation IEEE Trans Med Imaging 28 2009 405 414
    • (2009) IEEE Trans Med Imaging , vol.28 , pp. 405-414
    • Kang, D.1    Suh, D.C.2    Ra, J.B.3
  • 22
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 1986 307 310 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 23
    • 71649111814 scopus 로고    scopus 로고
    • Three-dimensional imaging core laboratory of the endovascular aneurysm repair trials: Validation of methodology
    • T.R. Wyss, F. Dick, A. England, L.C. Brown, A.D. Rodway, and R.M. Greenhalgh Three-dimensional imaging core laboratory of the endovascular aneurysm repair trials: validation of methodology Eur J Vasc Endovasc Surg 38 2009 724 731
    • (2009) Eur J Vasc Endovasc Surg , vol.38 , pp. 724-731
    • Wyss, T.R.1    Dick, F.2    England, A.3    Brown, L.C.4    Rodway, A.D.5    Greenhalgh, R.M.6
  • 24
    • 84855538727 scopus 로고    scopus 로고
    • Heartbeat-related distension and displacement of the thoracic aorta in healthy volunteers
    • 10.1016/j.ejrad.2010.08.023
    • F. Rengier, T.F. Weber, V. Henninger, D. Böckler, H. Schumacher, and H. Kauczor Heartbeat-related distension and displacement of the thoracic aorta in healthy volunteers Eur J Radiol 2010 10.1016/j.ejrad.2010.08.023
    • (2010) Eur J Radiol
    • Rengier, F.1    Weber, T.F.2    Henninger, V.3    Böckler, D.4    Schumacher, H.5    Kauczor, H.6
  • 25
    • 44049089308 scopus 로고    scopus 로고
    • Mathematical analysis of DICOM CT datasets: Can endograft sizing be automated for complex anatomy?
    • discussion 1312
    • V.R. Goel, R.K. Greenberg, and D.P. Greenberg Mathematical analysis of DICOM CT datasets: can endograft sizing be automated for complex anatomy? J Vasc Surg 47 2008 1306 1312 discussion 1312
    • (2008) J Vasc Surg , vol.47 , pp. 1306-1312
    • Goel, V.R.1    Greenberg, R.K.2    Greenberg, D.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.