메뉴 건너뛰기




Volumn 22, Issue 4, 2011, Pages 773-779

Povidone-iodine as a corrosion inhibitor towards a low modulus beta Ti-45Nb implant alloy in a simulated body fluid

Author keywords

[No Author keywords available]

Indexed keywords

ALLOY SURFACES; ANODIC INHIBITORS; BACTERICIDAL AGENT; BETA TITANIUM ALLOY; CORROSION BEHAVIOR; ELECTROCHEMICAL RESPONSE; IMPLANT ALLOYS; LOW MODULUS; OPEN CIRCUIT POTENTIAL; POTENTIODYNAMIC POLARIZATION MEASUREMENTS; SALINE SOLUTIONS; SIMULATED BODY FLUIDS; TREATMENT OUTCOMES;

EID: 80051663910     PISSN: 09574530     EISSN: 15734838     Source Type: Journal    
DOI: 10.1007/s10856-011-4268-9     Document Type: Article
Times cited : (13)

References (21)
  • 1
    • 18244396345 scopus 로고    scopus 로고
    • Effects of chlorhexidine and povidone-iodine mouth rinses on the bond strength of an orthodontic composite
    • Demir A, Malkoc S, Sengun A, Koyuturk AE, Sener Y. Effects of chlorohexidine and povidone-iodine mouth rinses on the bond strength of an orthodontic composite. Angle Orthod. 2005;75(3):392-6. (Pubitemid 40627495)
    • (2005) Angle Orthodontist , vol.75 , Issue.3 , pp. 392-396
    • Demir, A.1    Malkoc, S.2    Sengun, A.3    Koyuturk, A.E.4    Sener, Y.5
  • 4
    • 33748658899 scopus 로고
    • Viscosity of mixtures of polyelectrolytes and simple electrolytes
    • Fuoss RM, Strauss VP. Viscosity of mixtures of polyelectrolytes and simple electrolytes. Ann N Y Acad Sci. 1949;51:836.
    • (1949) Ann N Y Acad Sci , vol.51 , pp. 836
    • Fuoss, R.M.1    Strauss, V.P.2
  • 5
    • 2642687722 scopus 로고
    • Microbiology of povidone-iodine
    • On Povidone, Digenis GA, Ansell J, editors. University of Kentucky College of Pharmacy
    • LaRocca R, LaRocca M-AK, Ansell JM. Microbiology of povidone-iodine, In: Proc. Intl. Symp. On Povidone, Digenis GA, Ansell J, editors. University of Kentucky College of Pharmacy 1983;101.
    • (1983) Proc. Intl. Symp. , pp. 101
    • LaRocca, R.1    LaRocca, M.-A.K.2    Ansell, J.M.3
  • 7
    • 0016038178 scopus 로고
    • Interaction of poly (vinyl-pyrrolidone) and iodine
    • Cournoyer RF, Siggia S. Interaction of poly (vinyl-pyrrolidone) and iodine. J Polym Sci. 1974;12:603.
    • (1974) J Polym Sci , vol.12 , pp. 603
    • Cournoyer, R.F.1    Siggia, S.2
  • 9
    • 0037309938 scopus 로고    scopus 로고
    • Comparison of 5% povidone-iodine solution against 1% povidone-iodine solution in preoperative cataract surgery antisepsis: A prospective randomised double blind study
    • DOI 10.1136/bjo.87.2.163
    • Ferguson AW, Scott JA, McGavigan J, Elton RA, McLean J, Schmidt U, Kelkar R, Dhillon B. Comparison of 5% povidone-iodine solution against 0.1% povidone-iodine solution in preoperative cataract surgery antisepsis: a prospective randomized double blind study. Br J Ophthalmol. 2003;87:163-7. (Pubitemid 36152742)
    • (2003) British Journal of Ophthalmology , vol.87 , Issue.2 , pp. 163-167
    • Ferguson, A.W.1    Scott, J.A.2    McGavigan, J.3    Elton, R.A.4    McLean, J.5    Schmidt, U.6    Kelkar, R.7    Dhillon, B.8
  • 10
    • 77954541658 scopus 로고    scopus 로고
    • Effect of povidone-iodine addition on the corrosion behavior of cp-Ti in normal saline
    • doi:10.1007/s10856-010-4001-0
    • Bhola R, Bhola SM, Mishra B, Olson DL. Effect of povidone-iodine addition on the corrosion behavior of cp-Ti in normal saline. J Mater Sci Mater Med. 2010. doi:10.1007/s10856-010-4001-0.
    • (2010) J Mater Sci Mater Med
    • Bhola, R.1    Bhola, S.M.2    Mishra, B.3    Olson, D.L.4
  • 12
    • 2442462136 scopus 로고    scopus 로고
    • Biocompatibility of β-stabilizing elements of titanium alloys
    • DOI 10.1016/j.biomaterials.2004.01.021, PII S0142961204000663
    • Eisenbarth E, Velten D, Muller M, Thull R, Breme J. Biocompatibility of β-stabilizing elements of titanium alloys. Biomaterials. 2004;25:5705-13. (Pubitemid 38624450)
    • (2004) Biomaterials , vol.25 , Issue.26 , pp. 5705-5713
    • Eisenbarth, E.1    Velten, D.2    Muller, M.3    Thull, R.4    Breme, J.5
  • 13
    • 9444243222 scopus 로고    scopus 로고
    • Metal ion release from metal implants
    • Hanawa T. Metal ion release from metal implants. Mater Sci Eng C. 2004;24:745-52.
    • (2004) Mater Sci Eng C , vol.24 , pp. 745-752
    • Hanawa, T.1
  • 14
    • 0037411338 scopus 로고    scopus 로고
    • Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti-29Nb-13Ta-4.6Zr
    • DOI 10.1016/S0142-9612(03)00069-3
    • Niinomi M. Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti-29Nb-13Ta-4.6Zr. Biomaterials. 2003;24:2673-83. (Pubitemid 36444590)
    • (2003) Biomaterials , vol.24 , Issue.16 , pp. 2673-2683
    • Niinomi, M.1
  • 15
    • 15744377092 scopus 로고    scopus 로고
    • ASTM Standard F-04.12.44, Conshohocken, PA, USA
    • ASTM Standard F-04.12.44, ASTM International, Conshohocken, PA, USA.
    • ASTM International
  • 16
    • 0035443932 scopus 로고    scopus 로고
    • 0 into a capacitance
    • 0) into a capacitance. Corrosion. 2001;57:747-8. (Pubitemid 32972801)
    • (2001) Corrosion , vol.57 , Issue.9 , pp. 747-748
    • Hsu, C.H.1    Mansfeld, F.2
  • 17
    • 23844482994 scopus 로고    scopus 로고
    • Corrosion inhibition of mild steel by aerobic biofilm
    • DOI 10.1016/j.electacta.2005.02.017, PII S0013468605001933
    • Chongdar S, Gunasekaran G, Kumar P. Corrosion inhibition of mild steel by aerobic biofilm. Electrochim Acta. 2005;50:4655-65. (Pubitemid 41165582)
    • (2005) Electrochimica Acta , vol.50 , Issue.24 , pp. 4655-4665
    • Chongdar, S.1    Gunasekaran, G.2    Kumar, P.3
  • 18
    • 70350675750 scopus 로고    scopus 로고
    • Corrosion inhibition of mild steel in 1 M H2SO4 by polyvinyl pyrrolidone and synergistic iodide additives
    • Umoren SA, Eduok UM, Oguzie EE. Corrosion inhibition of mild steel in 1 M H2SO4 by polyvinyl pyrrolidone and synergistic iodide additives. Portugaliae Electrochimica Acta. 2008;26(6):533-46.
    • (2008) Portugaliae Electrochimica Acta , vol.26 , Issue.6 , pp. 533-546
    • Umoren, S.A.1    Eduok, U.M.2    Oguzie, E.E.3
  • 19
    • 58849090081 scopus 로고    scopus 로고
    • Blends of polyvinyl pyrrolidone and polyacrylamide as corrosion inhibitors for aluminium in acidic medium
    • Umoren SA, Ebenso EE. Blends of polyvinyl pyrrolidone and polyacrylamide as corrosion inhibitors for aluminium in acidic medium. Indian J Chem Technol. 2008;15:355-63.
    • (2008) Indian J Chem Technol , vol.15 , pp. 355-363
    • Umoren, S.A.1    Ebenso, E.E.2
  • 20
    • 0036690005 scopus 로고    scopus 로고
    • Corrosion rates of stainless steel files in different irrigating solutions
    • Öztan, MD, Akman AA, Zaimoglu L, Bilgic S. Corrosion rates of stainless steel files in different irrigating solutions. Int Endod J. 2002;35:655-9.
    • (2002) Int Endod J , vol.35 , pp. 655-659
    • Öztan, M.D.1    Akman, A.A.2    Zaimoglu, L.3    Bilgic, S.4
  • 21
    • 80051669790 scopus 로고    scopus 로고
    • An electrochemical study on chlorhexidine gluconate addition to normal saline for oral implant applications
    • Bhola SM, Bhola R, Mishra B, Olson DL. An electrochemical study on chlorhexidine gluconate addition to normal saline for oral implant applications. J Mater Sci: Mater Med (submitted).
    • J Mater Sci: Mater Med (submitted)
    • Bhola, S.M.1    Bhola, R.2    Mishra, B.3    Olson, D.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.