메뉴 건너뛰기




Volumn 16, Issue 4, 2011, Pages 302-311

The development and potential of acoustic radiation force impulse (ARFI) imaging for carotid artery plaque characterization

Author keywords

atherosclerosis; carotid artery disease; carotid stenosis; endarterectomy carotid; imaging diagnostic; stroke; ultrasonography

Indexed keywords

ACOUSTIC RADIATION FORCE IMPULSE; ANGIOGRAPHY; ARTERY WALL; ATHEROMA; ATHEROSCLEROTIC PLAQUE; CALCIFICATION; CAROTID ARTERY; CAROTID ARTERY OBSTRUCTION; DIAGNOSTIC IMAGING; DISEASE ASSOCIATION; ECHOGRAPHY; EX VIVO STUDY; HUMAN; IMAGE QUALITY; IN VIVO STUDY; LIMB; PRIORITY JOURNAL; REVIEW; SOFT TISSUE; STROKE;

EID: 80051605783     PISSN: 1358863X     EISSN: 14770377     Source Type: Journal    
DOI: 10.1177/1358863X11400936     Document Type: Review
Times cited : (51)

References (43)
  • 1
    • 33846857559 scopus 로고    scopus 로고
    • Heart disease and stroke statistics-2007 update: A report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee
    • Rosamond W, Flegal K, Friday G, et al. Heart disease and stroke statistics-2007 update: A report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. Circulation. 2007 ; 115: e69-171
    • (2007) Circulation , vol.115 , pp. 69-171
    • Rosamond, W.1    Flegal, K.2    Friday, G.3
  • 2
    • 0026604325 scopus 로고    scopus 로고
    • Early clinical differentiation of cerebral infarction from severe atherosclerotic stenosis and cardioembolism
    • Timsit S, Sacco R, Mohr J, et al. Early clinical differentiation of cerebral infarction from severe atherosclerotic stenosis and cardioembolism. Stroke. 2007 ; 23: 486-491
    • (2007) Stroke , vol.23 , pp. 486-491
    • Timsit, S.1    Sacco, R.2    Mohr, J.3
  • 3
    • 0025734372 scopus 로고
    • North American Symptomatic Carotid Endarterectomy Trial C. Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis
    • North American Symptomatic Carotid Endarterectomy Trial C. Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. N Engl J Med. 1991 ; 325: 445-453
    • (1991) N Engl J Med , vol.325 , pp. 445-453
  • 4
    • 0025869608 scopus 로고
    • MRC European Carotid Surgery Trial: Interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis
    • Warlow C. MRC European Carotid Surgery Trial: interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis. Lancet. 1991 ; 337: 1235-1243
    • (1991) Lancet , vol.337 , pp. 1235-1243
    • Warlow, C.1
  • 5
    • 0028938324 scopus 로고
    • Endarterectomy for asymptomatic carotid artery stenosis
    • Endarterectomy for asymptomatic carotid artery stenosis. JAMA. 1995 ; 273: 1421-1428
    • (1995) JAMA , vol.273 , pp. 1421-1428
  • 8
    • 36849047800 scopus 로고    scopus 로고
    • Identifying the Carotid 'High Risk' Plaque: Is it Still a Riddle Wrapped up in an Enigma?
    • DOI 10.1016/j.ejvs.2007.09.004, PII S1078588407005837
    • Golledge J, Siew DA. Identifying the carotid 'high risk' plaque: is it still a riddle wrapped up in an enigma?. Eur J Vasc Endovasc Surg. 2008 ; 35: 2-8 (Pubitemid 350235238)
    • (2008) European Journal of Vascular and Endovascular Surgery , vol.35 , Issue.1 , pp. 2-8
    • Golledge, J.1    Siew, D.-A.2
  • 9
    • 0024983850 scopus 로고
    • Carotid plaque morphology and risk for stroke
    • Gomez CR. Carotid plaque morphology and risk for stroke. Stroke. 1990 ; 21: 148-151
    • (1990) Stroke , vol.21 , pp. 148-151
    • Gomez, C.R.1
  • 11
    • 0030961921 scopus 로고    scopus 로고
    • Coronary risk factors and plaque morphology in men with coronary disease who died suddenly
    • DOI 10.1056/NEJM199705013361802
    • Burke AP, Farb A, Malcom GT, Liang Y-H, Smialek J, Virmani R. Coronary risk factors and plaque morphology in men with coronary disease who died suddenly. N Engl J Med. 1997 ; 336: 1276-1282 (Pubitemid 27187780)
    • (1997) New England Journal of Medicine , vol.336 , Issue.18 , pp. 1276-1282
    • Burke, A.P.1    Farb, A.2    Malcom, G.T.3    Liang, Y.-H.4    Smialek, J.5    Virmani, R.6
  • 13
    • 0035903242 scopus 로고    scopus 로고
    • Clinical imaging of the high-risk or vulnerable atherosclerotic plaque
    • Fayad ZA, Fuster V. Clinical imaging of the high-risk or vulnerable atherosclerotic plaque. Circ Res. 2001 ; 89: 305-316 (Pubitemid 34132668)
    • (2001) Circulation Research , vol.89 , Issue.4 , pp. 305-316
    • Fayad, Z.A.1    Fuster, V.2
  • 15
    • 0036736391 scopus 로고    scopus 로고
    • Prospective controlled study of the natural history of asymptomatic 60% to 69% carotid stenosis according to ultrasonic plaque morphology
    • AbuRahma AF, Thiele SP, John T, Wulu J. Prospective controlled study of the natural history of asymptomatic 60% to 69% carotid stenosis according to ultrasonic plaque morphology. J Vasc Surg. 2002 ; 36: 437-442
    • (2002) J Vasc Surg , vol.36 , pp. 437-442
    • Aburahma, A.F.1    Thiele, S.P.2    John, T.3    Wulu, J.4
  • 18
    • 0033816454 scopus 로고    scopus 로고
    • Reproducibility of computer-quantified carotid plaque echogenicity: Can we overcome the subjectivity?
    • Sabetai MM, Tegos TJ, Nicolaides AN, Dhanjil S, Pare GJ, Stevens JM. Reproducibility of computer-quantified carotid plaque echogenicity: can we overcome the subjectivity?. Stroke. 2000 ; 31: 2189-2196
    • (2000) Stroke , vol.31 , pp. 2189-2196
    • Sabetai, M.M.1    Tegos, T.J.2    Nicolaides, A.N.3    Dhanjil, S.4    Pare, G.J.5    Stevens, J.M.6
  • 19
    • 33746413498 scopus 로고    scopus 로고
    • Optical coherence tomography for imaging the vulnerable plaque
    • Tearney GJ, Jang I-K, Bouma BE. Optical coherence tomography for imaging the vulnerable plaque. J Biomed Opt. 2006 ; 11: 021002
    • (2006) J Biomed Opt , vol.11 , pp. 021002
    • Tearney, G.J.1    Jang, I.-K.2    Bouma, B.E.3
  • 20
    • 33750499495 scopus 로고    scopus 로고
    • The potential role of optical coherence tomography in the evaluation of vulnerable carotid atheromatous plaques: A pilot study
    • DOI 10.1007/s00270-005-0176-z
    • Prabhudesai V, Phelan C, Yang Y, Wang RK, Cowling MG. The potential role of optical coherence tomography in the evaluation of vulnerable carotid atheromatous plaques: a pilot study. Cardiovasc Intervent Radiol. 2006 ; 29: 1039-1045 (Pubitemid 44661955)
    • (2006) CardioVascular and Interventional Radiology , vol.29 , Issue.6 , pp. 1039-1045
    • Prabhudesai, V.1    Phelan, C.2    Yang, Y.3    Wang, R.K.4    Cowling, M.G.5
  • 21
    • 34250643578 scopus 로고    scopus 로고
    • High-resolution magnetic resonance imaging using gadolinium-based contrast agent for atherosclerotic carotid plaque
    • DOI 10.1016/j.surneu.2006.09.037, PII S0090301906009578
    • Kawahara I, Morikawa M, Honda M, et al. High-resolution magnetic resonance imaging using gadolinium-based contrast agent for atherosclerotic carotid plaque. Surg Neurol. 2007 ; 68: 60-65 (Pubitemid 46935289)
    • (2007) Surgical Neurology , vol.68 , Issue.1 , pp. 60-65
    • Kawahara, I.1    Morikawa, M.2    Honda, M.3    Kitagawa, N.4    Tsutsumi, K.5    Nagata, I.6    Hayashi, T.7    Koji, T.8
  • 23
    • 34249793701 scopus 로고    scopus 로고
    • Reproducibility of high-resolution MRI for the identification and the quantification of carotid atherosclerotic plaque components: Consequences for prognosis studies and therapeutic trials
    • DOI 10.1161/STROKEAHA.106.479139, PII 0000767020070600000036
    • Touze E, Toussaint J-F, Coste J, et al. Reproducibility of high-resolution MRI for the identification and the quantification of carotid atherosclerotic plaque components: consequences for prognosis studies and therapeutic trials. Stroke. 2007 ; 38: 1812-1819 (Pubitemid 46847252)
    • (2007) Stroke , vol.38 , Issue.6 , pp. 1812-1819
    • Touze, E.1    Toussaint, J.-F.2    Coste, J.3    Schmitt, E.4    Bonneville, F.5    Vandermarcq, P.6    Gauvrit, J.-Y.7    Douvrin, F.8    Meder, J.-F.9    Mas, J.-L.10    Oppenheim, C.11
  • 24
    • 0036663803 scopus 로고    scopus 로고
    • Observations of tissue response to acoustic radiation force: Opportunities for imaging
    • Nightingale K, Bentley R, Trahey GE. Observations of tissue response to acoustic radiation force: opportunities for imaging. Ultrason Imaging. 2002 ; 24: 129-138 (Pubitemid 36008600)
    • (2002) Ultrasonic Imaging , vol.24 , Issue.3 , pp. 129-138
    • Nightingale, K.1    Bentley, R.2    Trahey, G.3
  • 25
    • 0036218695 scopus 로고    scopus 로고
    • Acoustic radiation force impulse imaging: In vivo demonstration of clinical feasibility
    • DOI 10.1016/S0301-5629(01)00499-9, PII S0301562901004999
    • Nightingale K, Soo MS, Nightingale R, Trahey G. Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility. Ultrasound Med Biol. 2002 ; 28: 227-235 (Pubitemid 34286420)
    • (2002) Ultrasound in Medicine and Biology , vol.28 , Issue.2 , pp. 227-235
    • Nightingale, K.1    Soo, M.S.2    Nightingale, R.3    Trahey, G.4
  • 26
    • 0034062318 scopus 로고    scopus 로고
    • A finite element model of remote palpation of breast lesions using radiation force: Factors affecting tissue displacement
    • Nightingale KR, Nightingale RW, Palmeri ML, Trahey GE. A finite element model of remote palpation of breast lesions using radiation force: factors affecting tissue displacement. Ultrason Imaging. 2000 ; 22: 35-54 (Pubitemid 30266279)
    • (2000) Ultrasonic Imaging , vol.22 , Issue.1 , pp. 35-54
    • Nightingale, K.R.1    Nightingale, R.W.2    Palmeri, M.L.3    Trahey, G.E.4
  • 27
    • 0036525593 scopus 로고    scopus 로고
    • Acoustic radiation force impulse imaging of in vivo vastus medialis muscle under varying isometric load
    • Nightingale KR, Nightingale RW, Stutz DL, Trahey GE. Acoustic radiation force impulse imaging of in vivo vastus medialis muscle under varying isometric load. Ultrason Imaging. 2002 ; 24: 100-108
    • (2002) Ultrason Imaging , vol.24 , pp. 100-108
    • Nightingale, K.R.1    Nightingale, R.W.2    Stutz, D.L.3    Trahey, G.E.4
  • 29
    • 0003978799 scopus 로고    scopus 로고
    • Information for manufacturers seeking marketing clearance of diagnostic ultrasound systems and transducers
    • FDA Center for Devices and Radiological Health Washington DC: US Department of Health and Human Services
    • FDA Center for Devices and Radiological Health. Information for manufacturers seeking marketing clearance of diagnostic ultrasound systems and transducers. Technical report. Washington DC: US Department of Health and Human Services, 1997.
    • (1997) Technical Report
  • 31
    • 0031021607 scopus 로고    scopus 로고
    • Polyvinyl alcohol cryogel: An ideal phantom material for MR studies of arterial flow and elasticity
    • DOI 10.1002/mrm.1910370230
    • Chu KC, Rutt BK. Polyvinyl alcohol cryogel: an ideal phantom material for MR studies of arterial flow and elasticity. Magn Reson Med. 1997 ; 37: 314-319 (Pubitemid 27045408)
    • (1997) Magnetic Resonance in Medicine , vol.37 , Issue.2 , pp. 314-319
    • Chu, K.C.1    Rutt, B.K.2
  • 33
    • 33947692197 scopus 로고    scopus 로고
    • Estimation of polyvinyl alcohol cryogel mechanical properties with four ultrasound elastography methods and comparison with gold standard testings
    • Fromageau J, Gennisson JL, Schmitt C, Maurice RL, Mongrain R, Cloutier G. Estimation of polyvinyl alcohol cryogel mechanical properties with four ultrasound elastography methods and comparison with gold standard testings. IEEE Trans Ultrason Ferroelectr Freq Control. 2007 ; 54: 498-509
    • (2007) IEEE Trans Ultrason Ferroelectr Freq Control , vol.54 , pp. 498-509
    • Fromageau, J.1    Gennisson, J.L.2    Schmitt, C.3    Maurice, R.L.4    Mongrain, R.5    Cloutier, G.6
  • 34
    • 0038401196 scopus 로고    scopus 로고
    • A pulsating coronary vessel phantom for two- and three-dimensional intravascular ultrasound studies
    • DOI 10.1016/S0301-5629(02)00730-5
    • Nadkarni SK, Austin H, Mills G, Boughner D, Fenster A. A pulsating coronary vessel phantom for two- and three-dimensional intravascular ultrasound studies. Ultrasound Med Biol. 2003 ; 29: 621-628 (Pubitemid 36561431)
    • (2003) Ultrasound in Medicine and Biology , vol.29 , Issue.4 , pp. 621-628
    • Nadkarni, S.K.1    Austin, H.2    Mills, G.3    Boughner, D.4    Fenster, A.5
  • 36
    • 8844239224 scopus 로고    scopus 로고
    • Acoustic radiation force impulse imaging of the mechanical properties of arteries: In vivo and ex vivo results
    • DOI 10.1016/j.ultrasmedbio.2004.07.022, PII S0301562904001905
    • Trahey GE, Palmeri ML, Bentley RC, Nightingale KR. Acoustic radiation force impulse imaging of the mechanical properties of arteries: in vivo and ex vivo results. Ultrasound Med Biol. 2004 ; 30: 1163-1171 (Pubitemid 39531622)
    • (2004) Ultrasound in Medicine and Biology , vol.30 , Issue.9 , pp. 1163-1171
    • Trahey, G.E.1    Palmeri, M.L.2    Bentley, R.C.3    Nightingale, K.R.4
  • 37
    • 33846231022 scopus 로고    scopus 로고
    • Guidelines for noninvasive vascular laboratory testing: A report from the American Society of Echocardiography and the Society for Vascular Medicine and Biology
    • DOI 10.1177/1358863x06070516
    • Gerhard-Herman M, Gardin JM, Jaff M, Mohler E, Roman M, Naqvi TZ. Guidelines for noninvasive vascular laboratory testing: a report from the American Society of Echocardiography and the Society for Vascular Medicine and Biology. Vasc Med. 2006 ; 11: 183-200 (Pubitemid 46099265)
    • (2006) Vascular Medicine , vol.11 , Issue.3 , pp. 183-200
    • Gerhard-Herman, M.1    Gardin, J.M.2    Jaff, M.3    Mohler, E.4    Roman, M.5    Naqvi, T.Z.6
  • 38
    • 3042519588 scopus 로고    scopus 로고
    • A finite element model for performing intravascular ultrasound elastography of human atherosclerotic coronary arteries
    • DOI 10.1016/j.ultrasmedbio.2004.04.005, PII S030156290400105X
    • Baldewsing RA, de Korte CL, Schaar JA, Mastik F, van der Steen AFW. A finite element model for performing intravascular ultrasound elastography of human atherosclerotic coronary arteries. Ultrasound Med Biol. 2004 ; 30: 803-813 (Pubitemid 38829546)
    • (2004) Ultrasound in Medicine and Biology , vol.30 , Issue.6 , pp. 803-813
    • Baldewsing, R.A.1    De Korte, C.L.2    Schaar, J.A.3    Mastik, F.4    Van Der Steen, A.F.W.5
  • 39
    • 0027516690 scopus 로고
    • Distribution of circumferential stress in ruptured and stable atherosclerotic lesions: A structural analysis with histopathological correlation
    • Cheng GC, Loree HM, Kamm RD, Fishbein MC, Lee RT. Distribution of circumferential stress in ruptured and stable atherosclerotic lesions. A structural analysis with histopathological correlation. Circulation. 1994 ; 87: 1179-1187 (Pubitemid 23110390)
    • (1993) Circulation , vol.87 , Issue.4 , pp. 1179-1187
    • Cheng, G.C.1    Loree, H.M.2    Kamm, R.D.3    Fishbein, M.C.4    Lee, R.T.5
  • 42
    • 67349164631 scopus 로고    scopus 로고
    • Acoustic radiation force impulse imaging for noninvasive characterization of carotid artery atherosclerotic plaques: A feasibility study
    • Dahl JJ, Dumont DM, Allen JD, Miller EM, Trahey GE. Acoustic radiation force impulse imaging for noninvasive characterization of carotid artery atherosclerotic plaques: a feasibility study. Ultrasound Med Biol. 2009 ; 35: 707-716
    • (2009) Ultrasound Med Biol , vol.35 , pp. 707-716
    • Dahl, J.J.1    Dumont, D.M.2    Allen, J.D.3    Miller, E.M.4    Trahey, G.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.