Volumn 2, Issue 6, 2008, Pages 939-947

Statistical approach of assessing the reliability of glucose sensors: The GLYCENSIT procedure

Author keywords

Glucose measurement; Glucose sensor(s); Glycemia monitoring; Sensor validation; Standardized evaluation; Statistical analysis

Indexed keywords


EID: 80051590604     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229680800200604     Document Type: Conference Paper
Times cited : (5)

References (33)
  • 1
    • 33845508852 scopus 로고    scopus 로고
    • Clinical development of continuous glucose monitoring systems: Considerations for the optimal strategy
    • Heinemann L. Clinical development of continuous glucose monitoring systems: considerations for the optimal strategy. Diabetes Res Clin Pract. 2006;74:82-92.
    • (2006) Diabetes Res Clin Pract. , vol.74 , pp. 82-92
    • Heinemann, L.1
  • 2
    • 2142728611 scopus 로고    scopus 로고
    • Glucose Monitoring Study Group. Continuous glucose monitoring with glucose sensors: Calibration and assessment criteria
    • Lodwig V, Heinemann L, Glucose Monitoring Study Group. Continuous glucose monitoring with glucose sensors: calibration and assessment criteria. Diabetes Technol Ther. 2003;5(4):572-86.
    • (2003) Diabetes Technol Ther. , vol.5 , Issue.4 , pp. 572-586
    • Lodwig, V.1    Heinemann, L.2
  • 3
    • 0000004140 scopus 로고
    • Measurement in medicine: The analysis of method comparison studies
    • Altman DG, Bland JM. Measurement in medicine: the analysis of method comparison studies. Statistician. 1983;32:307-17.
    • (1983) Statistician. , vol.32 , pp. 307-317
    • Altman, D.G.1    Bland, J.M.2
  • 4
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307-10.
    • (1986) Lancet. , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 0023714852 scopus 로고
    • New approach to technical and clinical evaluation of devices for self-monitoring of blood glucose
    • Koschinsky T, Dannehl K, Gries FA. New approach to technical and clinical evaluation of devices for self-monitoring of blood glucose. Diabetes Care. 1988;11(8):619-29.
    • (1988) Diabetes Care. , vol.11 , Issue.8 , pp. 619-629
    • Koschinsky, T.1    Dannehl, K.2    Gries, F.A.3
  • 7
    • 27644565961 scopus 로고    scopus 로고
    • Diabetes Research in Children Network Study Group. Limitations of statistical measures of error in assessing the accuracy of continuous glucose sensors
    • Kollman C, Wilson DM, Wysocki T, Tamborlane WV, Beck RW, Diabetes Research in Children Network Study Group. Limitations of statistical measures of error in assessing the accuracy of continuous glucose sensors. Diabetes Technol Ther. 2005;7(5):665-72.
    • (2005) Diabetes Technol Ther. , vol.7 , Issue.5 , pp. 665-672
    • Kollman, C.1    Wilson, D.M.2    Wysocki, T.3    Tamborlane, W.V.4    Beck, R.W.5
  • 10
  • 12
    • 3342981187 scopus 로고    scopus 로고
    • Evaluating the accuracy of continuous glucose-monitoring sensors: Continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data
    • Kovatchev BP, Gonder-Frederick LA, Cox DJ, Clarke WL. Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data. Diabetes Care. 2004;27(8):1922-8.
    • (2004) Diabetes Care. , vol.27 , Issue.8 , pp. 1922-1928
    • Kovatchev, B.P.1    Gonder-Frederick, L.A.2    Cox, D.J.3    Clarke, W.L.4
  • 13
    • 0030985974 scopus 로고    scopus 로고
    • Reservations on the use of error grid analysis for the validation of blood glucose assays. [Comment]
    • Gough DA, Botvinick EL. Reservations on the use of error grid analysis for the validation of blood glucose assays. [Comment]. Diabetes Care. 1997;20(6):1034-6.
    • (1997) Diabetes Care. , vol.20 , Issue.6 , pp. 1034-1036
    • Gough, D.A.1    Botvinick, E.L.2
  • 14
    • 33746629303 scopus 로고    scopus 로고
    • A critical appraisal of the continuous glucose-error grid analysis
    • Wentholt IM, Hoekstra JB, Devries JH. A critical appraisal of the continuous glucose-error grid analysis. Diabetes Care. 2006;29(8):1805-11.
    • (2006) Diabetes Care. , vol.29 , Issue.8 , pp. 1805-1811
    • Wentholt, I.M.1    Hoekstra, J.B.2    Devries, J.H.3
  • 15
    • 0033855803 scopus 로고    scopus 로고
    • A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose
    • Parkes JL, Slatin SL, Pardo S, Ginsberg BH. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care. 2000;23(8):1143-8.
    • (2000) Diabetes Care. , vol.23 , Issue.8 , pp. 1143-1148
    • Parkes, J.L.1    Slatin, S.L.2    Pardo, S.3    Ginsberg, B.H.4
  • 16
    • 44249090496 scopus 로고    scopus 로고
    • Parameters affecting postprandial blood glucose: Effects of blood glucose measurement errors
    • Koschinsky T, Heckermann S, Heinemann L. Parameters affecting postprandial blood glucose: effects of blood glucose measurement errors. J Diabetes Sci Technol. 2008;2(1):58-66.
    • (2008) J Diabetes Sci Technol. , vol.2 , Issue.1 , pp. 58-66
    • Koschinsky, T.1    Heckermann, S.2    Heinemann, L.3
  • 17
    • 27644442974 scopus 로고    scopus 로고
    • Validation of the Continuous Glucose Monitoring System (CGMS) by the use of two CGMS simultaneously in pregnant women with type 1 diabetes mellitus
    • Kerssen A, De Valk HW, Visser GH. Validation of the Continuous Glucose Monitoring System (CGMS) by the use of two CGMS simultaneously in pregnant women with type 1 diabetes mellitus. Diabetes Technol Ther. 2005;7(5):699-706.
    • (2005) Diabetes Technol Ther. , vol.7 , Issue.5 , pp. 699-706
    • Kerssen, A.1    De Valk, H.W.2    Visser, G.H.3
  • 19
    • 25644435718 scopus 로고    scopus 로고
    • Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis
    • Clarke WL, Anderson S, Farhy L, Breton M, Gonder-Frederick L, Cox D, Kovatchev B. Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis. Diabetes Care. 2005;28(10):2412-7.
    • (2005) Diabetes Care. , vol.28 , Issue.10 , pp. 2412-2417
    • Clarke, W.L.1    Anderson, S.2    Farhy, L.3    Breton, M.4    Gonder-Frederick, L.5    Cox, D.6    Kovatchev, B.7
  • 21
    • 26444580110 scopus 로고    scopus 로고
    • Error grid analysis of noninvasive glucose monitoring via gingival crevicular fluid
    • Yamaguchi M, Kambe S, Yamazaki K, Kobayashi M. Error grid analysis of noninvasive glucose monitoring via gingival crevicular fluid. IEEE Trans Biomed Eng. 2005;52(10):1796-8.
    • (2005) IEEE Trans Biomed Eng. , vol.52 , Issue.10 , pp. 1796-1798
    • Yamaguchi, M.1    Kambe, S.2    Yamazaki, K.3    Kobayashi, M.4
  • 22
    • 1442275314 scopus 로고    scopus 로고
    • The need for separate performance goals for glucose sensors in the hypoglycemic, normoglycemic, and hyperglycemic ranges. [Editorial]
    • Klonoff DC. The need for separate performance goals for glucose sensors in the hypoglycemic, normoglycemic, and hyperglycemic ranges. [Editorial]. Diabetes Care. 2004;27(3):834-6.
    • (2004) Diabetes Care. , vol.27 , Issue.3 , pp. 834-836
    • Klonoff, D.C.1
  • 25
    • 0242300559 scopus 로고    scopus 로고
    • Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor
    • Boyne MS, Silver DM, Kaplan J, Saudek CD. Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes. 2003;52(11):2790-4.
    • (2003) Diabetes. , vol.52 , Issue.11 , pp. 2790-2794
    • Boyne, M.S.1    Silver, D.M.2    Kaplan, J.3    Saudek, C.D.4
  • 26
    • 0242332246 scopus 로고    scopus 로고
    • Glucose sensors and the alternate site testing-like phenomenon: Relationship between rapid blood glucose changes and glucose sensor signals
    • Koschinsky T, Jungheim K, Heinemann L. Glucose sensors and the alternate site testing-like phenomenon: relationship between rapid blood glucose changes and glucose sensor signals. Diabetes Technol Ther. 2003;5(5):829-42.
    • (2003) Diabetes Technol Ther. , vol.5 , Issue.5 , pp. 829-842
    • Koschinsky, T.1    Jungheim, K.2    Heinemann, L.3
  • 27
    • 1642452596 scopus 로고    scopus 로고
    • Closed-loop insulin delivery the path to physiological glucose control
    • Steil GM, Panteleon AE, Rebrin K. Closed-loop insulin delivery the path to physiological glucose control. Adv Drug Deliv Rev. 2004;56(2):125-44.
    • (2004) Adv Drug Deliv Rev. , vol.56 , Issue.2 , pp. 125-144
    • Steil, G.M.1    Panteleon, A.E.2    Rebrin, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.