메뉴 건너뛰기




Volumn 170, Issue 1, 2011, Pages 64-68

Infrared thermographic profiles of vessel sealing devices on thyroid parenchyma

Author keywords

harmonic; LigaSure; parenchyma; temperature; thermal spread; thermography; thyroid; vessel sealing

Indexed keywords

ARTICLE; COOLING; DISSECTION; ELECTRONIC VESSEL SEALING; FEMALE; HEMOSTASIS; HIGH TEMPERATURE; INFRARED PHOTOGRAPHY; INTERMETHOD COMPARISON; NONHUMAN; PRIORITY JOURNAL; SURGICAL RISK; THERMAL EXPOSURE; THERMAL INJURY; THERMAL TIME; THYROID GLAND; ULTRASONIC DISSECTION;

EID: 80051552230     PISSN: 00224804     EISSN: 10958673     Source Type: Journal    
DOI: 10.1016/j.jss.2011.03.005     Document Type: Article
Times cited : (26)

References (32)
  • 1
    • 3042611944 scopus 로고    scopus 로고
    • Prospective study of postoperative complications after total thyroidectomy for multinodular goiters by surgeons with experience in endocrine surgery
    • A.R. Zambudio, J. Rodriguez, and J. Riquelme Prospective study of postoperative complications after total thyroidectomy for multinodular goiters by surgeons with experience in endocrine surgery Ann Surg 240 2004 18
    • (2004) Ann Surg , vol.240 , pp. 18
    • Zambudio, A.R.1    Rodriguez, J.2    Riquelme, J.3
  • 2
    • 78651351898 scopus 로고    scopus 로고
    • A comparison of the LigaSure and harmonic scalpel in thyroid surgery: A single institution review
    • B. Zarebczan, D. Mohanty, and H. Chen A comparison of the LigaSure and harmonic scalpel in thyroid surgery: A single institution review Ann Surg Oncol 18 2011 214
    • (2011) Ann Surg Oncol , vol.18 , pp. 214
    • Zarebczan, B.1    Mohanty, D.2    Chen, H.3
  • 3
    • 54349098280 scopus 로고    scopus 로고
    • Preserving function and quality of life after thyroid and parathyroid surgery
    • J.T. Adler, R.S. Sippel, and S. Schaefer Preserving function and quality of life after thyroid and parathyroid surgery Lancet Oncol 9 2008 1069
    • (2008) Lancet Oncol , vol.9 , pp. 1069
    • Adler, J.T.1    Sippel, R.S.2    Schaefer, S.3
  • 4
    • 77952308096 scopus 로고    scopus 로고
    • Outpatient thyroidectomy is safe and reasonable: Experience with more than 1000 planned outpatient procedures
    • 582
    • S.K. Snyder, K.S. Hamid, and C.R. Roberson Outpatient thyroidectomy is safe and reasonable: Experience with more than 1000 planned outpatient procedures J Am Coll Surg 210 2010 575 582
    • (2010) J Am Coll Surg , vol.210 , pp. 575
    • Snyder, S.K.1    Hamid, K.S.2    Roberson, C.R.3
  • 5
    • 77952786378 scopus 로고    scopus 로고
    • Morbidity and mortality of thyroidectomy for substernal goiter
    • B. Abboud, G. Sleilaty, and N. Mallak Morbidity and mortality of thyroidectomy for substernal goiter Head Neck 32 2010 744
    • (2010) Head Neck , vol.32 , pp. 744
    • Abboud, B.1    Sleilaty, G.2    Mallak, N.3
  • 6
    • 77955919247 scopus 로고    scopus 로고
    • Parathyroid hormone deficiency after total thyroidectomy: Incidence and time
    • L. Youngwirth, J. Benavidez, and R. Sippel Parathyroid hormone deficiency after total thyroidectomy: Incidence and time J Surg Res 163 2010 69
    • (2010) J Surg Res , vol.163 , pp. 69
    • Youngwirth, L.1    Benavidez, J.2    Sippel, R.3
  • 7
    • 33846407259 scopus 로고    scopus 로고
    • Risks and consequences of incidental parathyroidectomy during thyroid resection
    • R.S. Sippel, O. Ozgul, and G.K. Hartig Risks and consequences of incidental parathyroidectomy during thyroid resection ANZ J Surg 77 2007 33
    • (2007) ANZ J Surg , vol.77 , pp. 33
    • Sippel, R.S.1    Ozgul, O.2    Hartig, G.K.3
  • 8
    • 70450257865 scopus 로고    scopus 로고
    • A comparison of two methods of hemostasis in thyroidectomy
    • M.M. McNally, S.C. Agle, and R.F. Williams A comparison of two methods of hemostasis in thyroidectomy Am Surg 75 2009 1073
    • (2009) Am Surg , vol.75 , pp. 1073
    • Mcnally, M.M.1    Agle, S.C.2    Williams, R.F.3
  • 9
    • 70349310113 scopus 로고    scopus 로고
    • Thyroid hormone replacement after thyroid lobectomy
    • discussion 558
    • S.J. Stoll, S.C. Pitt, and J. Liu Thyroid hormone replacement after thyroid lobectomy Surgery 146 2009 554 discussion 558
    • (2009) Surgery , vol.146 , pp. 554
    • Stoll, S.J.1    Pitt, S.C.2    Liu, J.3
  • 10
    • 0028857030 scopus 로고
    • Outpatient thyroid and parathyroid surgery: A prospective study of feasibility, safety, and costs
    • discussion 1053
    • P.M. Mowschenson, and R.A. Hodin Outpatient thyroid and parathyroid surgery: A prospective study of feasibility, safety, and costs Surgery 118 1995 1051 discussion 1053
    • (1995) Surgery , vol.118 , pp. 1051
    • Mowschenson, P.M.1    Hodin, R.A.2
  • 11
    • 0019988248 scopus 로고
    • Total thyroidectomy: The treatment of choice for patients with differentiated thyroid cancer
    • O.H. Clark Total thyroidectomy: The treatment of choice for patients with differentiated thyroid cancer Ann Surg 196 1982 361
    • (1982) Ann Surg , vol.196 , pp. 361
    • Clark, O.H.1
  • 12
    • 9144238067 scopus 로고    scopus 로고
    • Comparison of different thyroidectomy techniques for benign thyroid disease
    • A. Koyuncu, H.S. Dokmetas, and M. Turan Comparison of different thyroidectomy techniques for benign thyroid disease Endocr J 50 2003 723
    • (2003) Endocr J , vol.50 , pp. 723
    • Koyuncu, A.1    Dokmetas, H.S.2    Turan, M.3
  • 13
    • 84865064985 scopus 로고    scopus 로고
    • Implementing the general use of dissection devices in thyroid surgery from prospective randomized trial to daily use
    • P.E. Goretzki, K. Schwarz, and B.J. Lammers Implementing the general use of dissection devices in thyroid surgery from prospective randomized trial to daily use Surg Technol Int 18 2009 86
    • (2009) Surg Technol Int , vol.18 , pp. 86
    • Goretzki, P.E.1    Schwarz, K.2    Lammers, B.J.3
  • 14
    • 67650647149 scopus 로고    scopus 로고
    • Use of the harmonic scalpel in thyroidectomy
    • D.J. Parker, K. Krupa, and R. Esler Use of the harmonic scalpel in thyroidectomy ANZ J Surg 79 2009 476
    • (2009) ANZ J Surg , vol.79 , pp. 476
    • Parker, D.J.1    Krupa, K.2    Esler, R.3
  • 15
    • 40749149195 scopus 로고    scopus 로고
    • The use of the Ligasure for hemostasis during thyroid lobectomy
    • discussion 384
    • S. Musunuru, S. Schaefer, and H. Chen The use of the Ligasure for hemostasis during thyroid lobectomy Am J Surg 195 2008 382 discussion 384
    • (2008) Am J Surg , vol.195 , pp. 382
    • Musunuru, S.1    Schaefer, S.2    Chen, H.3
  • 16
    • 47549110620 scopus 로고    scopus 로고
    • Prospective trial of the ultrasonic dissector in thyroid surgery
    • D.S. Leonard, and C. Timon Prospective trial of the ultrasonic dissector in thyroid surgery Head Neck 30 2008 904
    • (2008) Head Neck , vol.30 , pp. 904
    • Leonard, D.S.1    Timon, C.2
  • 17
    • 33947618422 scopus 로고    scopus 로고
    • Ligasure vessel sealing system versus conventional vessel ligation in thyroidectomy
    • U. Lepner, and T. Vaasna Ligasure vessel sealing system versus conventional vessel ligation in thyroidectomy Scand J Surg 96 2007 31
    • (2007) Scand J Surg , vol.96 , pp. 31
    • Lepner, U.1    Vaasna, T.2
  • 18
    • 79955807706 scopus 로고    scopus 로고
    • Prospective randomized trial of Ligasure versus harmonic hemostasis technique in thyroidectomy
    • R. Rahbari, A. Mathur, and M. Kitano Prospective randomized trial of Ligasure versus harmonic hemostasis technique in thyroidectomy Ann Surg Oncol 18 2011 1023
    • (2011) Ann Surg Oncol , vol.18 , pp. 1023
    • Rahbari, R.1    Mathur, A.2    Kitano, M.3
  • 19
    • 78249263185 scopus 로고    scopus 로고
    • Current status of surgical treatment for hemorrhoids-Systematic review and meta-analysis
    • J.S. Chen, and J.F. You Current status of surgical treatment for hemorrhoids-Systematic review and meta-analysis Chang Gung Med. J 33 2010 488
    • (2010) Chang Gung Med. J , vol.33 , pp. 488
    • Chen, J.S.1    You, J.F.2
  • 21
    • 68949162191 scopus 로고    scopus 로고
    • Is harmonic scalpel an effective tool for esophagectomy?
    • N. Waraich, J. Ahmed, and F. Rashid Is harmonic scalpel an effective tool for esophagectomy? Int J Surg 7 2009 330
    • (2009) Int J Surg , vol.7 , pp. 330
    • Waraich, N.1    Ahmed, J.2    Rashid, F.3
  • 22
    • 70349310087 scopus 로고    scopus 로고
    • Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy
    • Y. Pons, J. Gauthier, and E. Ukkola-Pons Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy Otolaryngol Head Neck Surg 141 2009 496
    • (2009) Otolaryngol Head Neck Surg , vol.141 , pp. 496
    • Pons, Y.1    Gauthier, J.2    Ukkola-Pons, E.3
  • 23
    • 57049134777 scopus 로고    scopus 로고
    • Operative time and other outcomes of the electrothermal bipolar vessel sealing system (LigaSure) versus other methods for surgical hemostasis: A meta-analysis
    • A. Macario, F. Dexter, and J. Sypal Operative time and other outcomes of the electrothermal bipolar vessel sealing system (LigaSure) versus other methods for surgical hemostasis: A meta-analysis Surg Innov 15 2008 284
    • (2008) Surg Innov , vol.15 , pp. 284
    • Macario, A.1    Dexter, F.2    Sypal, J.3
  • 24
    • 77949890354 scopus 로고    scopus 로고
    • LigaSure versus clamp-and-tie in thyroidectomy: A single-center experience
    • B. Cakabay, M.M. Sevinc, and I. Gomceli LigaSure versus clamp-and-tie in thyroidectomy: A single-center experience Adv Ther 26 2009 1035
    • (2009) Adv Ther , vol.26 , pp. 1035
    • Cakabay, B.1    Sevinc, M.M.2    Gomceli, I.3
  • 25
    • 51449107607 scopus 로고    scopus 로고
    • Ligasure versus ultracision in thyroid surgery: A prospective randomized study
    • P.V. Sartori, S. De Fina, and G. Colombo Ligasure versus ultracision in thyroid surgery: A prospective randomized study Langenbecks Arch Surg 393 2008 655
    • (2008) Langenbecks Arch Surg , vol.393 , pp. 655
    • Sartori, P.V.1    De Fina, S.2    Colombo, G.3
  • 26
    • 35748971736 scopus 로고    scopus 로고
    • Evaluation of surgical energy devices for vessel sealing and peripheral energy spread in a porcine model
    • G.W. Hruby, F.C. Marruffo, and E. Durak Evaluation of surgical energy devices for vessel sealing and peripheral energy spread in a porcine model J Urol 178 2007 2689
    • (2007) J Urol , vol.178 , pp. 2689
    • Hruby, G.W.1    Marruffo, F.C.2    Durak, E.3
  • 27
    • 43749124249 scopus 로고    scopus 로고
    • Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT)
    • F.J. Kim, M.F. Chammas Jr., and E. Gewehr Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT) Surg Endosc 22 2008 1464
    • (2008) Surg Endosc , vol.22 , pp. 1464
    • Kim, F.J.1    Chammas, Jr.M.F.2    Gewehr, E.3
  • 28
    • 0037306077 scopus 로고    scopus 로고
    • Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model
    • J. Landman, K. Kerbl, and J. Rehman Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model J Urol 169 2003 697
    • (2003) J Urol , vol.169 , pp. 697
    • Landman, J.1    Kerbl, K.2    Rehman, J.3
  • 29
    • 39149134560 scopus 로고    scopus 로고
    • Comparison of four energy-based vascular sealing and cutting instruments: A porcine model
    • B. Person, D.A. Vivas, and D. Ruiz Comparison of four energy-based vascular sealing and cutting instruments: A porcine model Surg Endosc 22 2008 534
    • (2008) Surg Endosc , vol.22 , pp. 534
    • Person, B.1    Vivas, D.A.2    Ruiz, D.3
  • 30
    • 41149147463 scopus 로고    scopus 로고
    • Tissue response to surgical energy devices
    • C.K. Phillips, G.W. Hruby, and E. Durak Tissue response to surgical energy devices Urology 71 2008 744
    • (2008) Urology , vol.71 , pp. 744
    • Phillips, C.K.1    Hruby, G.W.2    Durak, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.