1
-
-
0041357211
-
Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries
-
Harold KL, Pollinger H, Matthews BD, Kercher KW, Sing RF, Heniford BT. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc 2003;17:1228-1230.
-
(2003)
Surg Endosc
, vol.17
, pp. 1228-1230
-
-
Harold, K.L.1
Pollinger, H.2
Matthews, B.D.3
Kercher, K.W.4
Sing, R.F.5
Heniford, B.T.6
-
2
-
-
85047693399
-
How safe is high-power ultrasonic dissection
-
Emam T, Cuschieri A. How safe is high-power ultrasonic dissection. Ann Surg 2002;237:186-191.
-
(2002)
Ann Surg
, vol.237
, pp. 186-191
-
-
Emam, T.1
Cuschieri, A.2
-
3
-
-
0346034851
-
Determination of temperature elevation in tissue during the application of the harmonic scalpel
-
Koch C, Friedrich T, Metternich F, Tannapfel A, Reimann HP, Eichfeld U. Determination of temperature elevation in tissue during the application of the harmonic scalpel. Ultrasound Med Biol 2003;29:301-309.
-
(2003)
Ultrasound Med Biol
, vol.29
, pp. 301-309
-
-
Koch, C.1
Friedrich, T.2
Metternich, F.3
Tannapfel, A.4
Reimann, H.P.5
Eichfeld, U.6
-
4
-
-
1642397609
-
Evaluation of the ultrasonic dissector in thyroid surgery. A prospective randomised study
-
Defechereux T, Rinken F, Maweja S, Hamoir E, Meurisse M. Evaluation of the ultrasonic dissector in thyroid surgery. A prospective randomised study. Acta Chir Belg 2003;103:274-277.
-
(2003)
Acta Chir Belg
, vol.103
, pp. 274-277
-
-
Defechereux, T.1
Rinken, F.2
Maweja, S.3
Hamoir, E.4
Meurisse, M.5
-
5
-
-
0036781220
-
Thyroidectomy using the harmonic scalpel: Analysis of 105 consecutive cases
-
Shemen L. Thyroidectomy using the harmonic scalpel: analysis of 105 consecutive cases. Otolaryngol Head Neck Surg 2002;127:284-288.
-
(2002)
Otolaryngol Head Neck Surg
, vol.127
, pp. 284-288
-
-
Shemen, L.1
-
6
-
-
14644394238
-
A randomized, prospective, parallel group study comparing the harmonic scalpel to electrocautery in thyroidectomy
-
Cordon C, Fajardo R, Ramirez J, Herrera MF. A randomized, prospective, parallel group study comparing the harmonic scalpel to electrocautery in thyroidectomy. Surgery 2005;137:337-341.
-
(2005)
Surgery
, vol.137
, pp. 337-341
-
-
Cordon, C.1
Fajardo, R.2
Ramirez, J.3
Herrera, M.F.4
-
7
-
-
0036160006
-
The use of the harmonic scalpel vs. conventional knot tying for vessel ligation in thyroid surgery
-
Siperstein AE, Berber E, Morkoyun E. The use of the harmonic scalpel vs. conventional knot tying for vessel ligation in thyroid surgery. Arch Surg 2002;137:137-142.
-
(2002)
Arch Surg
, vol.137
, pp. 137-142
-
-
Siperstein, A.E.1
Berber, E.2
Morkoyun, E.3
-
8
-
-
0034097614
-
Ultrasionically activated shears in thyroidectomies: A randomized trial
-
Voutilainen PE, Haglund CH. Ultrasionically activated shears in thyroidectomies: a randomized trial. Ann Surg 2000;231:322-328.
-
(2000)
Ann Surg
, vol.231
, pp. 322-328
-
-
Voutilainen, P.E.1
Haglund, C.H.2
-
11
-
-
33750192616
-
Randomized controlled trial of harmonic scalpel use during thyroidectomy
-
Miccoli P, Berti P, Dionigi GL, D'Agostino J, Orlandini C, Donatini G. Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg 2006;132:1069-1073.
-
(2006)
Arch Otolaryngol Head Neck Surg
, vol.132
, pp. 1069-1073
-
-
Miccoli, P.1
Berti, P.2
Dionigi, G.L.3
D'Agostino, J.4
Orlandini, C.5
Donatini, G.6
-
12
-
-
34248340359
-
The use of a harmonic scalpel in thyroid surgery: Report of a three year experience
-
Koutsoumanis K, Koutras A, Drimousis P, et al. The use of a harmonic scalpel in thyroid surgery: report of a three year experience. Am J Surg 2007;193:693-696.
-
(2007)
Am J Surg
, vol.193
, pp. 693-696
-
-
Koutsoumanis, K.1
Koutras, A.2
Drimousis, P.3
-
13
-
-
0021346315
-
A new absorbable ligat-ing clip for use in cholecystectomy
-
Allan A, Cooper MJ, Leaper DJ. A new absorbable ligat-ing clip for use in cholecystectomy. J R Coll Surg Edinb 1984;29:53-54.
-
(1984)
J R Coll Surg Edinb
, vol.29
, pp. 53-54
-
-
Allan, A.1
Cooper, M.J.2
Leaper, D.J.3
-
14
-
-
0021864610
-
A clinical evaluation of absorbable polydioxanone ligating clips in abdominal and pelvic operations
-
Clarke-Pearson DL, Creasman WT. A clinical evaluation of absorbable polydioxanone ligating clips in abdominal and pelvic operations. Surg Gynecol Obstet 1985;161:250-252.
-
(1985)
Surg Gynecol Obstet
, vol.161
, pp. 250-252
-
-
Clarke-Pearson, D.L.1
Creasman, W.T.2
-
15
-
-
33749343788
-
Protocol design and current status of CLVIT: A randomized controlled multicenter relevance trial comparing clips versus ligatures in thyroid surgery
-
Seiler CM, Frohlich BE, Veit JA, et al. Protocol design and current status of CLVIT: a randomized controlled multicenter relevance trial comparing clips versus ligatures in thyroid surgery. Trials 2006;7:27.
-
(2006)
Trials
, vol.7
, pp. 27
-
-
Seiler, C.M.1
Frohlich, B.E.2
Veit, J.A.3
-
16
-
-
0032951086
-
Acute thermal injury to the canine jejunal free flap: Electrocautery versus ultrasonic dissection
-
Birch DW, Park A, Shuhaibar H. Acute thermal injury to the canine jejunal free flap: electrocautery versus ultrasonic dissection. Am Surg 1999;65:334-337.
-
(1999)
Am Surg
, vol.65
, pp. 334-337
-
-
Birch, D.W.1
Park, A.2
Shuhaibar, H.3
-
17
-
-
0033920503
-
Evaluation of the Ultracision ultrasonic dissector in thyroid surgery: Prospective randomized study
-
Meurisse M, Defechereux T, Maweja S, Degauque C, Vandelaer M, Hamoir E. Evaluation of the Ultracision ultrasonic dissector in thyroid surgery: prospective randomized study. Annal Chir 2000;125:468-472.
-
(2000)
Annal Chir
, vol.125
, pp. 468-472
-
-
Meurisse, M.1
Defechereux, T.2
Maweja, S.3
Degauque, C.4
Vandelaer, M.5
Hamoir, E.6
-
19
-
-
0036690312
-
Minimally invasive video-assisted thyroidectomy: Multiinstitutional experience
-
Miccoli P, Bellantone R, Mourad M, Walz M, Raffaellii M, Beri P. Minimally invasive video-assisted thyroidectomy: multiinstitutional experience. World J Surg 2002;26:972-975.
-
(2002)
World J Surg
, vol.26
, pp. 972-975
-
-
Miccoli, P.1
Bellantone, R.2
Mourad, M.3
Walz, M.4
Raffaellii, M.5
Beri, P.6
|