메뉴 건너뛰기




Volumn 27, Issue 8, 2011, Pages

Non-iterative harmonic Bz algorithm in MREIT

Author keywords

[No Author keywords available]

Indexed keywords

ADVERSE EFFECT; CONDUCTING OBJECTS; CONDUCTIVITY CHANGES; CONDUCTIVITY DISTRIBUTIONS; CONDUCTIVITY IMAGE; CROSS SECTIONAL IMAGE; ELLIPTIC BOUNDARY VALUE PROBLEM; EQUIPOTENTIAL LINES; GLOBAL STRUCTURE; HARMONIC B; ITERATIVE PROCEDURES; LOCAL REGION; MAGNETIC RESONANCE ELECTRICAL IMPEDANCE TOMOGRAPHIES; MR SIGNALS; MRI SCANNERS; NON-ITERATIVE; RECONSTRUCTION ALGORITHMS; TOMOGRAPHIC IMAGES; TWO-DIMENSIONAL IMAGING;

EID: 79961225335     PISSN: 02665611     EISSN: 13616420     Source Type: Journal    
DOI: 10.1088/0266-5611/27/8/085003     Document Type: Article
Times cited : (17)

References (14)
  • 1
    • 0037986214 scopus 로고    scopus 로고
    • Uniqueness and reconstruction in magnetic resonance-electrical impedance tomography (MR-EIT)
    • DOI 10.1088/0967-3334/24/2/368, PII S0967333403550079
    • Ider Y Z, Onart S and Lionheart W R B 2003 Uniqueness and reconstruction in magnetic resonance-electrical impedance tomography (MR-EIT) Physiol. Meas. 24 591-604 (Pubitemid 36648422)
    • (2003) Physiological Measurement , vol.24 , Issue.2 , pp. 591-604
    • Ider, Y.Z.1    Onart, S.2    Lionheart, W.R.B.3
  • 3
    • 0024561625 scopus 로고
    • In vivo detection of applied electric currents by magnetic resonance imaging
    • Joy M L G, Scott G C and Henkelman R M 1989 In vivo detection of applied electric currents by magnetic resonance imaging Magn. Reson. Imaging 7 89-94
    • (1989) Magn. Reson. Imaging , vol.7 , Issue.1 , pp. 89-94
    • Joy, M.L.G.1    Scott, G.C.2    Henkelman, R.M.3
  • 4
    • 0036157954 scopus 로고    scopus 로고
    • Magnetic resonance electrical impedance tomography (MREIT): Simulation study of J-substitution algorithm
    • DOI 10.1109/10.979355
    • Kwon O, Woo E J, Yoon J R and Seo J K 2002 Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm IEEE Trans. Biomed. Eng. 48 160-7 (Pubitemid 34112725)
    • (2002) IEEE Transactions on Biomedical Engineering , vol.49 , Issue.2 , pp. 160-167
    • Kwon, O.1    Woo, E.J.2    Yoon, J.-R.3    Seo, J.K.4
  • 7
    • 31644435098 scopus 로고    scopus 로고
    • Conductivity image reconstruction from defective data in MREIT: Numerical simulation and animal experiment
    • DOI 10.1109/TMI.2005.862150
    • Lee S, Seo J K, Park C, Lee B I, Woo E J, Lee S Y, Kwon O and Hahn J 2006 Conductivity image reconstruction from defective data in MREIT: numerical simulation and animal experiment IEEE Trans. Med. Imaging 25 168-76 (Pubitemid 43172571)
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , Issue.2 , pp. 168-176
    • Lee, S.-H.1    Seo, J.K.2    Park, C.3    Lee, B.I.4    Woo, E.J.5    Lee, S.Y.6    Kwon, O.7    Hahn, J.8
  • 8
    • 36749073048 scopus 로고    scopus 로고
    • Conductivity imaging with a single measurement of boundary and interior data
    • DOI 10.1088/0266-5611/23/6/017, PII S0266561107462128
    • Nachman A, Tamasan A and Timonov A 2007 Conductivity imaging with a single measurement of boundary and interior data Inverse Problems 23 2551-63 (Pubitemid 350212315)
    • (2007) Inverse Problems , vol.23 , Issue.6 , pp. 2551-2563
    • Nachman, A.1    Tamasan, A.2    Timonov, A.3
  • 9
    • 70350333274 scopus 로고    scopus 로고
    • Recovering the conductivity from a single measurement of interior data
    • Nachman A, Tamasan A and Timonov A 2009 Recovering the conductivity from a single measurement of interior data Inverse Problems 25 035014
    • (2009) Inverse Problems , vol.25 , Issue.3 , pp. 035014
    • Nachman, A.1    Tamasan, A.2    Timonov, A.3
  • 12
    • 78650039779 scopus 로고    scopus 로고
    • Magnetic resonance electrical impedance tomography (MREIT)
    • Seo J K and Woo E J 2011 Magnetic resonance electrical impedance tomography (MREIT) SIAM Rev. 53 40-68
    • (2011) SIAM Rev. , vol.53 , Issue.1 , pp. 40-68
    • Seo, J.K.1    Woo, E.J.2
  • 13
    • 0038644775 scopus 로고    scopus 로고
    • Reconstruction of conductivity and current density images using only one component of magnetic field measurements
    • DOI 10.1109/TBME.2003.816080
    • Seo J K, Yoon J R, Woo E J and Kwon O 2003 Reconstruction of conductivity and current density images using only one component of magnetic field measurements IEEE Trans. Biomed. Eng. 50 1121-4 (Pubitemid 37047562)
    • (2003) IEEE Transactions on Biomedical Engineering , vol.50 , Issue.9 , pp. 1121-1124
    • Seo, J.K.1    Yoon, J.-R.2    Woo, E.J.3    Kwon, O.4
  • 14
    • 58149302549 scopus 로고    scopus 로고
    • Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging
    • Woo E J and Seo J K 2008 Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging Physiol. Meas. 29 R1-26
    • (2008) Physiol. Meas. , vol.29 , Issue.10 , pp. 1-26
    • Woo, E.J.1    Seo, J.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.