메뉴 건너뛰기




Volumn 5, Issue SUPPL. 1, 2011, Pages

An investigation into the likely impact of oxy-coal retrofit on fire-side corrosion behavior in utility boilers

Author keywords

Fire side corrosion; Oxy coal combustion; Utility boilers

Indexed keywords

BITUMINOUS COAL; BOILER FIRING; COAL COMBUSTION; CORROSION RATE; CORROSIVE EFFECTS; ELECTROCHEMICAL CORROSION; SUPERHEATERS; TEMPERATURE;

EID: 79961171853     PISSN: 17505836     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijggc.2011.05.021     Document Type: Article
Times cited : (12)

References (10)
  • 3
    • 72549089503 scopus 로고
    • High-temperature fireside corrosion monitoring in the superheater section of a pulverized-coal-fired boiler
    • Bakker W.T., et al. High-temperature fireside corrosion monitoring in the superheater section of a pulverized-coal-fired boiler. EPRI 1992.
    • (1992) EPRI
    • Bakker, W.T.1
  • 4
    • 4444359507 scopus 로고    scopus 로고
    • A multi-point corrosion monitoring system applied in a 1,300 MW coal-fired boiler
    • Davis K.A., et al. A multi-point corrosion monitoring system applied in a 1,300 MW coal-fired boiler. Anti-Corros. Methods Mater. 2004, 51(5).
    • (2004) Anti-Corros. Methods Mater. , vol.51 , Issue.5
    • Davis, K.A.1
  • 5
    • 33646176139 scopus 로고    scopus 로고
    • Prediction and real-time monitoring techniques for corrosion characterization in furnaces
    • Linjewile T., et al. Prediction and real-time monitoring techniques for corrosion characterization in furnaces. Mater. High Temp. 2003, 20:175.
    • (2003) Mater. High Temp. , vol.20 , pp. 175
    • Linjewile, T.1
  • 7
    • 4444373450 scopus 로고    scopus 로고
    • Cost of corrosion in the electric power industry - an update
    • Syrett B.C., Gorman J.A. Cost of corrosion in the electric power industry - an update. Mater. Perform. 2003, 42(2):32-38.
    • (2003) Mater. Perform. , vol.42 , Issue.2 , pp. 32-38
    • Syrett, B.C.1    Gorman, J.A.2
  • 8
    • 48049116646 scopus 로고    scopus 로고
    • Development of fire-side waterwall corrosion correlations using pilot-scale test furnace
    • Shim H.-S., et al. Development of fire-side waterwall corrosion correlations using pilot-scale test furnace. Fuel 2008, 15-16:3353-3361.
    • (2008) Fuel , pp. 3353-3361
    • Shim, H.-S.1
  • 9
    • 33846980080 scopus 로고    scopus 로고
    • CFD evaluation of waterwall wastage in coal-fired utility boilers
    • Valentine J.R., et al. CFD evaluation of waterwall wastage in coal-fired utility boilers. Energy Fuels 2007, 21:242.
    • (2007) Energy Fuels , vol.21 , pp. 242
    • Valentine, J.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.