메뉴 건너뛰기




Volumn 87, Issue 15-16, 2008, Pages 3353-3361

Development of fireside waterwall corrosion correlations using pilot-scale test furnace

Author keywords

Coal combustion; Fireside corrosion; Waterwall wastage

Indexed keywords

CHIMNEYS; CHLORINE; COMPUTATIONAL FLUID DYNAMICS; CORRELATION METHODS; CORROSION; DEPOSITS; DYNAMICS; FLUE GASES; FLUES; FLUID DYNAMICS; FLUID MECHANICS; FURNACES; METALS; PULVERIZED FUEL; SULFUR; TESTING;

EID: 48049116646     PISSN: 00162361     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.fuel.2008.05.016     Document Type: Article
Times cited : (42)

References (29)
  • 1
    • 19944408620 scopus 로고    scopus 로고
    • The effect of deposits on waterwall corrosion in fossil fueled boilers
    • Bakker W.T. The effect of deposits on waterwall corrosion in fossil fueled boilers. Mater High Temp 20 2 (2003) 161-168
    • (2003) Mater High Temp , vol.20 , Issue.2 , pp. 161-168
    • Bakker, W.T.1
  • 2
    • 4444373450 scopus 로고    scopus 로고
    • Cost of corrosion in the electric power industry - an update
    • Syrett B.C., and Gorman J.A. Cost of corrosion in the electric power industry - an update. Mater Perform 42 (2003) 32-38
    • (2003) Mater Perform , vol.42 , pp. 32-38
    • Syrett, B.C.1    Gorman, J.A.2
  • 3
    • 30744452225 scopus 로고    scopus 로고
    • Benchmarking boiler tube failures - part 2
    • Patrick J., Oldani R., and Behren D.V. Benchmarking boiler tube failures - part 2. Power 149 9 (2005) 55-59
    • (2005) Power , vol.149 , Issue.9 , pp. 55-59
    • Patrick, J.1    Oldani, R.2    Behren, D.V.3
  • 4
    • 33646176139 scopus 로고    scopus 로고
    • Prediction and real-time monitoring techniques for corrosion characterisation in furnaces
    • Linjewile M., Valentine J., Davis K.A., Harding N.S., and Cox W.M. Prediction and real-time monitoring techniques for corrosion characterisation in furnaces. Mater High Temp 20 2 (2003) 175-183
    • (2003) Mater High Temp , vol.20 , Issue.2 , pp. 175-183
    • Linjewile, M.1    Valentine, J.2    Davis, K.A.3    Harding, N.S.4    Cox, W.M.5
  • 5
    • 48049101262 scopus 로고    scopus 로고
    • EPRI. Waterwall wastage mechanisms in coal-fired boilers: the effect of coal chemistry on Waterwall wastage, TR-1004021; 2001.
    • EPRI. Waterwall wastage mechanisms in coal-fired boilers: the effect of coal chemistry on Waterwall wastage, TR-1004021; 2001.
  • 6
    • 48049106064 scopus 로고    scopus 로고
    • Reaction Engineering International. Development of advanced fireside waterwall corrosion model for pulverized coal-fired facilities; KEPRI final report; 2007.
    • Reaction Engineering International. Development of advanced fireside waterwall corrosion model for pulverized coal-fired facilities; KEPRI final report; 2007.
  • 7
    • 0031337437 scopus 로고    scopus 로고
    • Prediction of corrosion rate for alloys exposed to reducing/sulfidizing combustion gases
    • Kung S.C. Prediction of corrosion rate for alloys exposed to reducing/sulfidizing combustion gases. Mater Perform 36 12 (1997) 36-40
    • (1997) Mater Perform , vol.36 , Issue.12 , pp. 36-40
    • Kung, S.C.1
  • 8
    • 19944408620 scopus 로고    scopus 로고
    • The effect of deposits on waterwall corrosion in fossil fueled boilers
    • Bakker W.T. The effect of deposits on waterwall corrosion in fossil fueled boilers. Mater High Temp 20 2 (2003) 161-168
    • (2003) Mater High Temp , vol.20 , Issue.2 , pp. 161-168
    • Bakker, W.T.1
  • 9
    • 48049094018 scopus 로고    scopus 로고
    • Shim HS, Valentine JR, Davis KA, Seo SI, Kim EH, Kim TH. Investigation of fireside corrosion in a pilot-scale test furnace. In: Proceedings of the 31st international technical conference on coal utilization and fuel systems, June 10-15, Clearwater, Florida, USA; 2007.
    • Shim HS, Valentine JR, Davis KA, Seo SI, Kim EH, Kim TH. Investigation of fireside corrosion in a pilot-scale test furnace. In: Proceedings of the 31st international technical conference on coal utilization and fuel systems, June 10-15, Clearwater, Florida, USA; 2007.
  • 10
    • 0035189989 scopus 로고    scopus 로고
    • Effects of fuel composition and combustion parameters on furnace wall fireside corrosion in pulverised coal-fired boilers
    • Davis C.J., James P.J., Pinder L.W., and Mehta A.K. Effects of fuel composition and combustion parameters on furnace wall fireside corrosion in pulverised coal-fired boilers. Mater Sci Forum 369-372 (2001) 857-864
    • (2001) Mater Sci Forum , vol.369-372 , pp. 857-864
    • Davis, C.J.1    James, P.J.2    Pinder, L.W.3    Mehta, A.K.4
  • 11
    • 48049109920 scopus 로고    scopus 로고
    • Davis CJ, James PJ, Pinder LW, Mehta AK. Furnace wall fireside corrosion in PF-fired boilers: the riddle resolved, presented at united engineering foundation conference on effects of coal quality on power plant management: ash problems, Management and solutions, Park City, Utah; 2000.
    • Davis CJ, James PJ, Pinder LW, Mehta AK. Furnace wall fireside corrosion in PF-fired boilers: the riddle resolved, presented at united engineering foundation conference on effects of coal quality on power plant management: ash problems, Management and solutions, Park City, Utah; 2000.
  • 12
    • 48049090782 scopus 로고    scopus 로고
    • Bakker WT. Wastage in Low NOx Boilers, Root Causes and Remedies. EPRI Report TR11115; 1998.
    • Bakker WT. Wastage in Low NOx Boilers, Root Causes and Remedies. EPRI Report TR11115; 1998.
  • 13
    • 48049116744 scopus 로고    scopus 로고
    • Bakker WT, Kung SC, Heap MP, Valentine JR. Waterwall corrosion in low NOx boilers: root Causes and remedies. In: Proceedings of the EPRI-DOE-EPA combined utility air pollution control symposium: the mega symposium, vol 2: NOx and multi-pollutant controls; 1999 p. 13-17-13-30.
    • Bakker WT, Kung SC, Heap MP, Valentine JR. Waterwall corrosion in low NOx boilers: root Causes and remedies. In: Proceedings of the EPRI-DOE-EPA combined utility air pollution control symposium: the mega symposium, vol 2: NOx and multi-pollutant controls; 1999 p. 13-17-13-30.
  • 15
    • 84956365287 scopus 로고
    • A study of two chemical reaction models in turbulent coal combustion
    • Smith P.J., and Fletcher T.H. A study of two chemical reaction models in turbulent coal combustion. Comb Sci Technol 58 (1988) 59-76
    • (1988) Comb Sci Technol , vol.58 , pp. 59-76
    • Smith, P.J.1    Fletcher, T.H.2
  • 16
    • 48049122728 scopus 로고    scopus 로고
    • Smith PJ. 3-D Turbulent particle dispersion submodel development. DOE Quarterly progress report #4; 1992.
    • Smith PJ. 3-D Turbulent particle dispersion submodel development. DOE Quarterly progress report #4; 1992.
  • 17
    • 0027303450 scopus 로고
    • Three dimensional discrete ordinates modelling of radiative transfer in a geometrically complex furnace
    • Adams B.R., and Smith P.J. Three dimensional discrete ordinates modelling of radiative transfer in a geometrically complex furnace. Comb Sci Technol 88 5-6 (1993) 293-308
    • (1993) Comb Sci Technol , vol.88 , Issue.5-6 , pp. 293-308
    • Adams, B.R.1    Smith, P.J.2
  • 19
    • 33846980080 scopus 로고    scopus 로고
    • CFD evaluation of waterwall wastage in coal-fired utility boilers
    • Valentine J.R., Shim H.S., and Davis K.A. CFD evaluation of waterwall wastage in coal-fired utility boilers. Energy Fuels 21 (2007) 242-249
    • (2007) Energy Fuels , vol.21 , pp. 242-249
    • Valentine, J.R.1    Shim, H.S.2    Davis, K.A.3
  • 20
    • 48049091238 scopus 로고    scopus 로고
    • Bakker WT, Mok WY, Cox WM. High-temperature fireside corrosion monitoring in the superheater section of a pulverised-coal-fired boiler. EPRI, Palo Alto, CA, TR-101799; 1992.
    • Bakker WT, Mok WY, Cox WM. High-temperature fireside corrosion monitoring in the superheater section of a pulverised-coal-fired boiler. EPRI, Palo Alto, CA, TR-101799; 1992.
  • 21
    • 48049096458 scopus 로고    scopus 로고
    • Cox WM, Gearey D, Dawson JL. Corrosion-industrial problems treatment and control techniques. In: Proceedings of the Kuwait conference. Oxford: Pergamon Press; 1987, 83.
    • Cox WM, Gearey D, Dawson JL. Corrosion-industrial problems treatment and control techniques. In: Proceedings of the Kuwait conference. Oxford: Pergamon Press; 1987, 83.
  • 22
    • 0032179931 scopus 로고    scopus 로고
    • Use corrosion monitoring to minimize downtime and equipment failures
    • Oct
    • Kane R.D., and Cayard M.S. Use corrosion monitoring to minimize downtime and equipment failures. Chem Eng Prog (1998) 49-57 Oct
    • (1998) Chem Eng Prog , pp. 49-57
    • Kane, R.D.1    Cayard, M.S.2
  • 23
    • 48049122276 scopus 로고    scopus 로고
    • Farrell DM, Cox WM, Wrobel BA, Syrett BC. In: Proceedings of the symposium on corrosion in power utilities, National Association of Corrosion Engineers, Houston; 1987.
    • Farrell DM, Cox WM, Wrobel BA, Syrett BC. In: Proceedings of the symposium on corrosion in power utilities, National Association of Corrosion Engineers, Houston; 1987.
  • 24
    • 0027809592 scopus 로고
    • Real-time performance monitoring of fouling and under-deposit corrosion in cooling water systems
    • Winters M.A., Stokes P.S.N., Zuniga P.O., and Schlottenmeier D.J. Real-time performance monitoring of fouling and under-deposit corrosion in cooling water systems. Corr Sci 35 (1993) 1667-1675
    • (1993) Corr Sci , vol.35 , pp. 1667-1675
    • Winters, M.A.1    Stokes, P.S.N.2    Zuniga, P.O.3    Schlottenmeier, D.J.4
  • 25
    • 48049086863 scopus 로고    scopus 로고
    • Davis K, Lee C, Seeley R, Harding S, heap M, Cox W. Waterwall corrosion evaluation in coal-fired boilers using electrochemical measurements. In: 25th Int Tech Conf coal Utilization Fuel Systems, Clearwater, FL, March; 2000.
    • Davis K, Lee C, Seeley R, Harding S, heap M, Cox W. Waterwall corrosion evaluation in coal-fired boilers using electrochemical measurements. In: 25th Int Tech Conf coal Utilization Fuel Systems, Clearwater, FL, March; 2000.
  • 26
    • 48049123145 scopus 로고    scopus 로고
    • Davis KA, Green G, Linjewile T, Harding S. Evaluation of an on-line technique for corrosion characterization in furnaces. Joint International Combustion Symposium, AFRC/JFRC/IEA, Kauai, HI, September; 2001.
    • Davis KA, Green G, Linjewile T, Harding S. Evaluation of an on-line technique for corrosion characterization in furnaces. Joint International Combustion Symposium, AFRC/JFRC/IEA, Kauai, HI, September; 2001.
  • 28
    • 48049122519 scopus 로고    scopus 로고
    • Shim HS, Valentine JR, Davis KA, Seo SI, Kim TH. CFD Simulation of pilot-scale test furnace. Manuscript in preparation.
    • Shim HS, Valentine JR, Davis KA, Seo SI, Kim TH. CFD Simulation of pilot-scale test furnace. Manuscript in preparation.
  • 29
    • 0031360117 scopus 로고    scopus 로고
    • Effect of coal chlorine on the fireside corrosion of boiler furnace wall and superheater/reheater tubing
    • James P.J., and Pinder L.W. Effect of coal chlorine on the fireside corrosion of boiler furnace wall and superheater/reheater tubing. Mater High Temp 14 3 (1997) 187-196
    • (1997) Mater High Temp , vol.14 , Issue.3 , pp. 187-196
    • James, P.J.1    Pinder, L.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.