메뉴 건너뛰기




Volumn 74, Issue 2, 2011, Pages 110-113

Comparative analysis of the nuclear lens opalescence by the lens opacities classification system iii with nuclear density values provided by oculus pentacam: A cross-section study using pentacam nucleus staging software

Author keywords

Cataract classification; Cross sectional studies; Crystalline; Densitometry methods; Lens nucleus

Indexed keywords

ADULT; AGED; ANALYSIS OF VARIANCE; ARTICLE; CATARACT; CLASSIFICATION; COMPARATIVE STUDY; COMPUTER PROGRAM; CROSS-SECTIONAL STUDY; DENSITOMETRY; FEMALE; HUMAN; INSTRUMENTATION; LENS NUCLEUS; MALE; MIDDLE AGED; NONPARAMETRIC TEST; PATHOPHYSIOLOGY; VISUAL SYSTEM EXAMINATION;

EID: 79961114096     PISSN: 00042749     EISSN: 16782925     Source Type: Journal    
DOI: 10.1590/S0004-27492011000200008     Document Type: Article
Times cited : (64)

References (14)
  • 2
    • 0033761616 scopus 로고    scopus 로고
    • Incidence and progression of lens opacities in the Barbados Eye Studies
    • Leske MC, Wu SY, Nemesure B, Li X, Hennis A, Connell AM. Incidence and progression of lens opacities in the Barbados Eye Studies. Ophthalmology. 2000;107(7):1267-73.
    • (2000) Ophthalmology , vol.107 , Issue.7 , pp. 1267-1273
    • Leske, M.C.1    Wu, S.Y.2    Nemesure, B.3    Li, X.4    Hennis, A.5    Connell, A.M.6
  • 3
    • 0037254479 scopus 로고    scopus 로고
    • Clinical application of the lens opacities classification system III in the performance of phacoemulsification
    • Davison JA, Chylack LT. Clinical application of the lens opacities classification system III in the performance of phacoemulsification. J Cataract Refract Surg. 2003;29(1):138-45.
    • (2003) J Cataract Refract Surg , vol.29 , Issue.1 , pp. 138-145
    • Davison, J.A.1    Chylack, L.T.2
  • 5
    • 55649117729 scopus 로고    scopus 로고
    • Lens Opacities Classification System III: cataract grading variability between junior and senior staff at a Singapore hospital
    • Tan AC, Loon SC, Choi H, Thean L. Lens Opacities Classification System III: cataract grading variability between junior and senior staff at a Singapore hospital. J Cataract Refract Surg. 2008;34(11):1948-52.
    • (2008) J Cataract Refract Surg , vol.34 , Issue.11 , pp. 1948-1952
    • Tan, A.C.1    Loon, S.C.2    Choi, H.3    Thean, L.4
  • 6
  • 7
    • 52749095432 scopus 로고    scopus 로고
    • Comparison between central corneal thickness measurements by oculus pentacam and ultrasonic pachymetry
    • Al-Mezaine HS, Al-Amro SA, Kangave D, Sadaawy A, Wehaib TA, Al-Obeidan S. Comparison between central corneal thickness measurements by oculus pentacam and ultrasonic pachymetry. Int Ophthalmol. 2008;28(5):333-8.
    • (2008) Int Ophthalmol , vol.28 , Issue.5 , pp. 333-338
    • Al-Mezaine, H.S.1    Al-Amro, S.A.2    Kangave, D.3    Sadaawy, A.4    Wehaib, T.A.5    Al-Obeidan, S.6
  • 8
    • 33646693629 scopus 로고    scopus 로고
    • Anterior chamber measurements using Pentacam rotating Scheimpflug camera
    • Rabsilber TM, Khoramnia R, Auffarth GU. Anterior chamber measurements using Pentacam rotating Scheimpflug camera. J Cataract Refract Surg. 2006;32(3):456-9.
    • (2006) J Cataract Refract Surg , vol.32 , Issue.3 , pp. 456-459
    • Rabsilber, T.M.1    Khoramnia, R.2    Auffarth, G.U.3
  • 9
    • 34250698061 scopus 로고    scopus 로고
    • Measuring the cornea: the latest developments in corneal topography
    • Swartz T, Marten L, Wang M. Measuring the cornea: the latest developments in corneal topography. Curr Opin Ophthalmol. 2007;18(4):325-33.
    • (2007) Curr Opin Ophthalmol , vol.18 , Issue.4 , pp. 325-333
    • Swartz, T.1    Marten, L.2    Wang, M.3
  • 10
    • 55449119425 scopus 로고    scopus 로고
    • Correlation of lens density measured using the Pentacam Scheimpflug system with the Lens Opacities Classification System III grading score and visual acuity in age-related nuclear cataract
    • Pei X, Bao Y, Chen Y, Li X. Correlation of lens density measured using the Pentacam Scheimpflug system with the Lens Opacities Classification System III grading score and visual acuity in age-related nuclear cataract. Br J Ophthalmol. 2008;92(11):1471-5.
    • (2008) Br J Ophthalmol , vol.92 , Issue.11 , pp. 1471-1475
    • Pei, X.1    Bao, Y.2    Chen, Y.3    Li, X.4
  • 11
    • 0029316799 scopus 로고
    • Validation of methods for the assessment of cataract progression in the Roche European-American Anticataract Trial (REACT)
    • Comment in: Ophthalmic Epidemiol. 1996; 3(2): 59-60
    • Chylack LT Jr, Wolfe JK, Friend J, Tung W, Singer DM, Brown NP, et al. Validation of methods for the assessment of cataract progression in the Roche European-American Anticataract Trial (REACT). Ophthalmic Epidemiol. 1995;2(2):59-75. Comment in: Ophthalmic Epidemiol. 1996;3(2):59-60.
    • (1995) Ophthalmic Epidemiol , vol.2 , Issue.2 , pp. 59-75
    • Chylack Jr, L.T.1    Wolfe, J.K.2    Friend, J.3    Tung, W.4    Singer, D.M.5    Brown, N.P.6
  • 12
    • 55649108186 scopus 로고    scopus 로고
    • Corneal elevation and thickness in relation to the refractive status measured with the Pentacam Scheimpflug system
    • Uçakhan OO, Gesolu P, Ozkan M, Kanpolat A. Corneal elevation and thickness in relation to the refractive status measured with the Pentacam Scheimpflug system. J Cataract Refract Surg. 2008;34(11):1900-5.
    • (2008) J Cataract Refract Surg , vol.34 , Issue.11 , pp. 1900-1905
    • Uçakhan, O.O.1    Gesolu, P.2    Ozkan, M.3    Kanpolat, A.4
  • 13
    • 85047678674 scopus 로고
    • Study of nuclear cataract progression using the National Eye Institute Scheimpflug system
    • Datiles MB 3rd, Magno BV, Freidlin V. Study of nuclear cataract progression using the National Eye Institute Scheimpflug system. Br J Ophthalmol. 1995;79(6):527-34.
    • (1995) Br J Ophthalmol , vol.79 , Issue.6 , pp. 527-534
    • Datiles 3rd, M.B.1    Magno, B.V.2    Freidlin, V.3
  • 14
    • 0026476451 scopus 로고
    • Quantitative evaluation of nuclear cataract using image analysis
    • Sasaki K, Fujisawa K, Sakamoto Y. Quantitative evaluation of nuclear cataract using image analysis. Ophthalmic Res. 1992;24 Suppl 1:26-31.
    • (1992) Ophthalmic Res , vol.24 , Issue.SUPPL. 1 , pp. 26-31
    • Sasaki, K.1    Fujisawa, K.2    Sakamoto, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.