메뉴 건너뛰기




Volumn 38, Issue 8, 2011, Pages 4795-4801

Extremely efficient and deterministic approach to generating optimal ordering of diffusion MRI measurements

Author keywords

antipodal symmetry; diffusion MRI; diffusion MRI acquisition; gradient directions; multiple shell acquisition; ordered point set

Indexed keywords

COMPUTATIONAL EFFICIENCY; GEOMETRY; MAGNETIC RESONANCE IMAGING;

EID: 79961048098     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3615163     Document Type: Article
Times cited : (9)

References (46)
  • 1
    • 0022969218 scopus 로고
    • MR imaging of intravoxel incoherent motions: Application to diffusion and perfusion in neurologic disorders
    • D. Le Bihan, E. Breton, D. Lallemand, P. Grenier, E. Cabanis, and M. Lavaljeantet, MR imaging of intravoxel incoherent motions-application to diffusion and perfusion in neurologic disorders., Radiology 161, 401-407 (1986). http://radiology.rsna.org/content/161/2/401.abstract. (Pubitemid 17173295)
    • (1986) Radiology , vol.161 , Issue.2 , pp. 401-407
    • Le Bihan, D.1    Breton, E.2    Lallemand, D.3
  • 2
    • 0028154030 scopus 로고
    • MR diffusion tensor spectroscopy and imaging
    • P. J. Basser, J. Mattiello, and D. Le Bihan, MR diffusion tensor spectroscopy and imaging., Biophys. J. 66, 259-267 (1994). 10.1016/S0006- 3495(94)80775-1 (Pubitemid 24016507)
    • (1994) Biophysical Journal , vol.66 , Issue.1 , pp. 259-267
    • Basser, P.J.1    Mattiello, J.2    LeBihan, D.3
  • 3
    • 0029828575 scopus 로고    scopus 로고
    • Diffusion tensor MR imaging of the human brain
    • Chiro
    • C. Pierpaoli, P. Jezzard, P. J. Basser, A. Barnett, and G. Di Chiro, Diffusion tensor MR imaging of the human brain., Radiology 201, 637-648 (1996). http://radiology.rsnajnls.org/cgi/content/abstract/201/3/637
    • (1996) Radiology , vol.201 , pp. 637-648
    • Pierpaoli, C.1    Jezzard, P.2    Basser, P.J.3    Barnett, A.4    Di, G.5
  • 4
    • 0033007902 scopus 로고    scopus 로고
    • Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging
    • DOI 10.1002/15 31-8249(19 9902)45:2<265::A ID-ANA21>3.0.CO;2-3
    • S. Mori, B. J. Crain, V. P. Chacko, and P. C. M. Van Zijl, Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging., Ann. Neurol. 45, 265-269 (1999). 10.1002/1531-8249(199902) 45:21.0.CO;2-J (Pubitemid 29072377)
    • (1999) Annals of Neurology , vol.45 , Issue.2 , pp. 265-269
    • Mori, M.1    Crain, B.J.2    Chacko, V.P.3    Van Zijl, P.C.M.4
  • 6
    • 0033786160 scopus 로고    scopus 로고
    • In vivo fiber tractography using DT-MRI data
    • 10.1002/1522-2594(200010)44:41.0.CO;2-E
    • P. J. Basser, S. Pajevic, C. Pierpaoli, J. Duda, and A. Aldroubi, In vivo fiber tractography using DT-MRI data., Magn. Reson. Med. 44, 625-632 (2000). 10.1002/1522-2594(200010)44:41.0.CO;2-E
    • (2000) Magn. Reson. Med. , vol.44 , pp. 625-632
    • Basser, P.J.1    Pajevic, S.2    Pierpaoli, C.3    Duda, J.4    Aldroubi, A.5
  • 7
    • 0032835247 scopus 로고    scopus 로고
    • Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
    • DOI 10.1002/(S ICI)1522-2594(199 909)42:3<515::AI D-MRM14>3.0.CO;2- Q
    • D. K. Jones, M. A. Horsfield, and A. Simmons, Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging., Magn. Reson. Med. 42, 515-525 (1999). 10.1002/(SICI)1522-2594(199909)42:31.0.CO;2-3 (Pubitemid 29416213)
    • (1999) Magnetic Resonance in Medicine , vol.42 , Issue.3 , pp. 515-525
    • Jones, D.K.1    Horsfield, M.A.2    Simmons, A.3
  • 8
    • 1842533406 scopus 로고    scopus 로고
    • The Effect of Gradient Sampling Schemes on Measures Derived from Diffusion Tensor MRI: A Monte Carlo Study
    • DOI 10.1002/mrm.20033
    • D. K. Jones, The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study., Magn. Reson. Med. 51, 807-815 (2004). 10.1002/mrm.v51:4 (Pubitemid 38420459)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.4 , pp. 807-815
    • Jones, D.K.1
  • 10
    • 33646376290 scopus 로고
    • Spin diffusion measurements: Spin echoes in the presence of a time-dependent field gradient
    • 10.1063/1.1695690
    • E. O. Stejskal and J. E. Tanner, Spin diffusion measurements: spin echoes in the presence of a time-dependent field gradient., J. Chem. Phys. 42, 288-292 (1965). 10.1063/1.1695690
    • (1965) J. Chem. Phys. , vol.42 , pp. 288-292
    • Stejskal, E.O.1    Tanner, J.E.2
  • 11
    • 0029403019 scopus 로고
    • Inferring microstructural features and the physiological state of tissues from diffusion-weighted images
    • 10.1002/nbm.v8:7
    • P. J. Basser, Inferring microstructural features and the physiological state of tissues from diffusion-weighted images., NMR Biomed. 8, 333-344 (1995). 10.1002/nbm.v8:7
    • (1995) NMR Biomed. , vol.8 , pp. 333-344
    • Basser, P.J.1
  • 12
    • 0029908076 scopus 로고    scopus 로고
    • Toward a quantitative assessment of diffusion anisotropy
    • C. Pierpaoli and P. J. Basser, Toward a quantitative assessment of diffusion anisotropy., Magn. Reson. Med. 36, 893-906 (1996). 10.1002/mrm.v36:6 (Pubitemid 26396817)
    • (1996) Magnetic Resonance in Medicine , vol.36 , Issue.6 , pp. 893-906
    • Pierpaoli, C.1    Basser, P.J.2
  • 13
    • 33747872177 scopus 로고    scopus 로고
    • A unifying theoretical and algorithmic framework for least squares methods of estimation in diffusion tensor imaging
    • DOI 10.1016/j.jmr.2006.06.020, PII S1090780706001790, Thrid Annual Focus on Safety
    • C. G. Koay, L.-C. Chang, J. D. Carew, C. Pierpaoli, and P. J. Basser, A unifying theoretical and algorithmic framework for least squares methods of estimation in diffusion tensor imaging., J. Magn. Reson. 182, 115-125 (2006). 10.1016/j.jmr.2006.06.020 (Pubitemid 44293446)
    • (2006) Journal of Magnetic Resonance , vol.182 , Issue.1 , pp. 115-125
    • Koay, C.G.1    Chang, L.-C.2    Carew, J.D.3    Pierpaoli, C.4    Basser, P.J.5
  • 14
    • 34547591228 scopus 로고    scopus 로고
    • Error propagation framework for diffusion tensor imaging via diffusion tensor representations
    • DOI 10.1109/TMI.2007.897415
    • C. G. Koay, L. C. Chang, C. Pierpaoli, and P. J. Basser, Error propagation framework for diffusion tensor imaging via diffusion tensor representations., IEEE Trans. Med. Imaging 26, 1017-1034 (2007). 10.1109/TMI.2007.897415 (Pubitemid 47197684)
    • (2007) IEEE Transactions on Medical Imaging , vol.26 , Issue.8 , pp. 1017-1034
    • Koay, C.G.1    Chang, L.-C.2    Pierpaoli, C.3    Basser, P.J.4
  • 15
    • 44449114653 scopus 로고    scopus 로고
    • The elliptical cone of uncertainty and its normalized measures in diffusion tensor imaging
    • DOI 10.1109/TMI.2008.915663, 4427216
    • C. G. Koay, U. Nevo, L. C. Chang, C. Pierpaoli, and P. J. Basser, The elliptical cone of uncertainty and its normalized measures in diffusion tensor imaging., IEEE Trans. Med. Imaging 27, 834-846 (2008). 10.1109/TMI.2008.915663 (Pubitemid 351760855)
    • (2008) IEEE Transactions on Medical Imaging , vol.27 , Issue.6 , pp. 834-846
    • Koay, C.G.1    Nevo, U.2    Chang, L.-C.3    Pierpaoli, C.4    Basser, P.J.5
  • 17
    • 33748806066 scopus 로고    scopus 로고
    • Diffusion tensor imaging in hydrocephalus: Initial experience
    • Y. Assaf, L. Ben-Sira, S. Constantini, L. C. Chang, and L. Beni-Adani, Diffusion tensor imaging in hydrocephalus: initial experience., AJNR Am. J. Neuroradiol. 27, 1717-1724 (2006). http://www.ajnr.org.ezproxy.library.wisc.edu/ cgi/pmidlookup?view=longpmid=16971621 (Pubitemid 44413557)
    • (2006) American Journal of Neuroradiology , vol.27 , Issue.8 , pp. 1717-1724
    • Assaf, Y.1    Ben-Sira, L.2    Constantini, S.3    Chang, L.C.4    Beni-Adani, L.5
  • 18
    • 68349101109 scopus 로고    scopus 로고
    • Impact speed does not determine severity of spinal cord injury in mice with fixed impact displacement
    • 10.1089/neu.1995.12.1
    • J. H. Kim, T.-W. Tu, P. V. Bayly, and S.-K. Song, Impact speed does not determine severity of spinal cord injury in mice with fixed impact displacement., J. Neurotrauma 26, 1395-1404 (2009). 10.1089/neu.1995.12.1
    • (2009) J. Neurotrauma , vol.26 , pp. 1395-1404
    • Kim, J.H.1    Tu, T.-W.2    Bayly, P.V.3    Song, S.-K.4
  • 19
    • 73349136263 scopus 로고    scopus 로고
    • Diffusion tensor imaging detects axonal injury and demyelination in the spinal cord and cranial nerves of a murine model of globoid cell leukodystrophy
    • 10.1002/nbm.1420
    • A. A. Hofling, J. H. Kim, C. R. Fantz, M. S. Sands, and S.-K. Song, Diffusion tensor imaging detects axonal injury and demyelination in the spinal cord and cranial nerves of a murine model of globoid cell leukodystrophy., NMR Biomed. 22, 1100-1106 (2009). 10.1002/nbm.1420
    • (2009) NMR Biomed. , vol.22 , pp. 1100-1106
    • Hofling, A.A.1    Kim, J.H.2    Fantz, C.R.3    Sands, M.S.4    Song, S.-K.5
  • 20
    • 67651017508 scopus 로고    scopus 로고
    • In vivo diffusion tensor imaging of the human optic chiasm at sub-millimeter resolution
    • 10.1016/j.neuroimage.2009.05.098
    • J. E. Sarlls and C. Pierpaoli, In vivo diffusion tensor imaging of the human optic chiasm at sub-millimeter resolution., Neuroimage 47, 1244-1251 (2009). 10.1016/j.neuroimage.2009.05.098
    • (2009) Neuroimage , vol.47 , pp. 1244-1251
    • Sarlls, J.E.1    Pierpaoli, C.2
  • 21
    • 79551577532 scopus 로고    scopus 로고
    • Segmentation of fiber tracts based on an accuracy analysis on diffusion tensor software phantoms
    • 10.1016/j.neuroimage.2010.12.069
    • S. Barbieri, M. H. A. Bauer, J. Klein, C. Nimsky, and H. K. Hahn, Segmentation of fiber tracts based on an accuracy analysis on diffusion tensor software phantoms., Neuroimage 55, 532-544 (2011). 10.1016/j.neuroimage.2010.12. 069
    • (2011) Neuroimage , vol.55 , pp. 532-544
    • Barbieri, S.1    Bauer, M.H.A.2    Klein, J.3    Nimsky, C.4    Hahn, H.K.5
  • 22
    • 0035007493 scopus 로고    scopus 로고
    • Anisotropy in high angular resolution diffusion-weighted MRI
    • 10.1002/mrm.v45:6
    • L. R. Frank, Anisotropy in high angular resolution diffusion-weighted MRI., Magn. Reson. Med. 45, 935-939 (2001). 10.1002/mrm.v45:6
    • (2001) Magn. Reson. Med. , vol.45 , pp. 935-939
    • Frank, L.R.1
  • 23
    • 0036263865 scopus 로고    scopus 로고
    • Characterization of anisotropy in high angular resolution diffusion-weighted MRI
    • DOI 10.1002/mrm.10156
    • L. R. Frank, Characterization of anisotropy in high angular resolution diffusion-weighted MRI., Magn. Reson. Med. 47, 1083-1099 (2002). 10.1002/mrm.v47:6 (Pubitemid 34587400)
    • (2002) Magnetic Resonance in Medicine , vol.47 , Issue.6 , pp. 1083-1099
    • Frank, L.R.1
  • 24
    • 0036787434 scopus 로고    scopus 로고
    • High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
    • 10.1002/mrm.v48:4
    • D. S. Tuch, T. G. Reese, M. R. Wiegell, N. Makris, J. W. Belliveau, and V. J. Wedeen, High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity., Magn. Reson. Med. 48, 577-582 (2002). 10.1002/mrm.v48:4
    • (2002) Magn. Reson. Med. , vol.48 , pp. 577-582
    • Tuch, D.S.1    Reese, T.G.2    Wiegell, M.R.3    Makris, N.4    Belliveau, J.W.5    Wedeen, V.J.6
  • 25
    • 0347627835 scopus 로고    scopus 로고
    • Diffusion MRI of Complex Neural Architecture
    • DOI 10.1016/S0896-6273(03)00758-X
    • D. S. Tuch, T. G. Reese, M. R. Wiegell, and J. W. Van, Diffusion MRI of complex neural architecture., Neuron 40, 885-895 (2003). 10.1016/S0896-6273(03) 00758-X (Pubitemid 37522047)
    • (2003) Neuron , vol.40 , Issue.5 , pp. 885-895
    • Tuch, D.S.1    Reese, T.G.2    Wiegell, M.R.3    Wedeen, V.J.4
  • 26
    • 10044249029 scopus 로고    scopus 로고
    • Q-ball imaging
    • DOI 10.1002/mrm.20279
    • D. S. Tuch, Q-ball imaging., Magn. Reson. Med. 52, 1358-1372 (2004). 10.1002/mrm.v52:6 (Pubitemid 39612825)
    • (2004) Magnetic Resonance in Medicine , vol.52 , Issue.6 , pp. 1358-1372
    • Tuch, D.S.1
  • 27
    • 7444257398 scopus 로고    scopus 로고
    • Direct estimation of the fiber orientation density function from diffusion-weighted MRI data using spherical deconvolution
    • DOI 10.1016/j.neuroimage.2004.07.037, PII S1053811904004100
    • J.-D. Tournier, F. Calamante, D. G. Gadian, and A. Connelly, Direct estimation of the fiber orientation density function from diffusion-weighted MRI data using spherical deconvolution., Neuroimage 23, 1176-1185 (2004). 10.1016/j.neuroimage.2004.07.037 (Pubitemid 39446549)
    • (2004) NeuroImage , vol.23 , Issue.3 , pp. 1176-1185
    • Tournier, J.-D.1    Calamante, F.2    Gadian, D.G.3    Connelly, A.4
  • 28
    • 0142125688 scopus 로고    scopus 로고
    • Persistent angular structure: New insights from diffusion magnetic resonance imaging data
    • 10.1093/brain/122.1.99
    • K. M. Jansons and D. C. Alexander, Persistent angular structure: new insights from diffusion magnetic resonance imaging data., Inverse Probl. 19, 1031-1046 (2003). 10.1093/brain/122.1.99
    • (2003) Inverse Probl. , vol.19 , pp. 1031-1046
    • Jansons, K.M.1    Alexander, D.C.2
  • 29
    • 33744928872 scopus 로고    scopus 로고
    • Resolution of complex tissue microarchitecture using the diffusion orientation transform (DOT)
    • DOI 10.1016/j.neuroimage.2006.01.024, PII S1053811906000656
    • E. zarslan, T. M. Shepherd, B. C. Vemuri, S. J. Blackband, and T. H. Mareci, Resolution of complex tissue microarchitecture using the diffusion orientation transform (DOT)., Neuroimage 31, 1086-1103 (2006). 10.1016/j.neuroimage.2006.01.024 (Pubitemid 43851336)
    • (2006) NeuroImage , vol.31 , Issue.3 , pp. 1086-1103
    • Ozarslan, E.1    Shepherd, T.M.2    Vemuri, B.C.3    Blackband, S.J.4    Mareci, T.H.5
  • 30
    • 27644461834 scopus 로고    scopus 로고
    • Measurement of fiber orientation distributions using high angular resolution diffusion imaging
    • DOI 10.1002/mrm.20667
    • A. W. Anderson, Measurement of fiber orientation distributions using high angular resolution diffusion imaging., Magn. Reson. Med. 54, 1194-1206 (2005). 10.1002/mrm.v54:5 (Pubitemid 41567199)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.5 , pp. 1194-1206
    • Anderson, A.W.1
  • 31
  • 32
    • 0034567198 scopus 로고    scopus 로고
    • Condition number as a measure of noise performance of diffusion tensor data acquisition schemes with MRI
    • 10.1006/jmre.2000.2209
    • S. Skare, M. Hedehus, M. E. Moseley, and T.-Q. Li, Condition number as a measure of noise performance of diffusion tensor data acquisition schemes with MRI., J. Magn. Reson. 147, 340-352 (2000). 10.1006/jmre.2000.2209
    • (2000) J. Magn. Reson. , vol.147 , pp. 340-352
    • Skare, S.1    Hedehus, M.2    Moseley, M.E.3    Li, T.-Q.4
  • 33
    • 0035038227 scopus 로고    scopus 로고
    • Comparison of gradient encoding schemes for diffusion-tensor MRI
    • DOI 10.1002/jmri.1107
    • K. M. Hasan, D. L. Parker, and A. L. Alexander, Comparison of gradient encoding schemes for diffusion-tensor MRI., J. Magn. Reson Imaging 13, 769-780 (2001). 10.1002/jmri.v13:5 (Pubitemid 32381856)
    • (2001) Journal of Magnetic Resonance Imaging , vol.13 , Issue.5 , pp. 769-780
    • Hasan, K.M.1    Parker, D.L.2    Alexander, A.L.3
  • 35
    • 34247884377 scopus 로고    scopus 로고
    • Optimal acquisition orders of diffusion-weighted MRI measurements
    • DOI 10.1002/jmri.20905
    • P. A. Cook, M. Symms, P. A. Boulby, and D. C. Alexander, Optimal acquisition orders of diffusion-weighted MRI measurements., J. Magn. Reson Imaging 25, 1051-1058 (2007). 10.1002/jmri.v25:5 (Pubitemid 46697577)
    • (2007) Journal of Magnetic Resonance Imaging , vol.25 , Issue.5 , pp. 1051-1058
    • Cook, P.A.1    Symms, M.2    Boulby, P.A.3    Alexander, D.C.4
  • 36
    • 81355157205 scopus 로고    scopus 로고
    • Artifacts in diffusion MRI
    • in, edited by D. K. Jones (Oxford University Press, Oxford)
    • C. Pierpaoli, Artifacts in diffusion MRI., in Diffusion MRI, edited by, D. K. Jones, (Oxford University Press, Oxford, 2010), pp. 303-318.
    • (2010) Diffusion MRI , pp. 303-318
    • Pierpaoli, C.1
  • 37
    • 70249139069 scopus 로고    scopus 로고
    • Optimal real-time Q-ball imaging using regularized Kalman filtering with incremental orientation sets
    • 10.1016/j.media.2009.05.008
    • R. Deriche, J. Calder, and M. Descoteaux, Optimal real-time Q-ball imaging using regularized Kalman filtering with incremental orientation sets., Med. Image Anal. 13, 564-579 (2009). 10.1016/j.media.2009.05.008
    • (2009) Med. Image Anal. , vol.13 , pp. 564-579
    • Deriche, R.1    Calder, J.2    Descoteaux, M.3
  • 39
    • 79953126608 scopus 로고    scopus 로고
    • Analytically exact spiral scheme for generating uniformly distributed points on the unit sphere
    • 10.1016/j.jocs.2010.12.003
    • C. G. Koay, Analytically exact spiral scheme for generating uniformly distributed points on the unit sphere., Journal of Computation Science 2, 88-91 (2011). 10.1016/j.jocs.2010.12.003
    • (2011) Journal of Computation Science , vol.2 , pp. 88-91
    • Koay, C.G.1
  • 40
    • 0033874204 scopus 로고    scopus 로고
    • Distribution of points on a sphere with application to star catalogs
    • R. Bauer, Distribution of points on a sphere with application to star catalogs., J. Guid. Control Dyn. 23, 130-137 (2000). 10.2514/2.4497 (Pubitemid 30542049)
    • (2000) Journal of Guidance, Control, and Dynamics , vol.23 , Issue.1 , pp. 130-137
    • Bauer, R.1
  • 41
    • 0031542184 scopus 로고    scopus 로고
    • Distributing many points on a sphere
    • E. Saff and A. Kuijlaars, Distributing many points on a sphere., Math. Intell. 19, 5-11 (1997). 10.1007/BF03024331 (Pubitemid 127349280)
    • (1997) Mathematical Intelligencer , vol.19 , Issue.1 , pp. 5-11
    • Saff, E.B.1    Kuijlaars, A.B.J.2
  • 42
    • 0028001712 scopus 로고
    • A strategy for sampling on a sphere applied to 3D selective RF pulse design
    • DOI 10.1002/mrm.1910320614
    • S. Wong and M. Roos, A strategy for sampling on a sphere applied to 3D selective RF pulse design., Magn. Reson. Med. 32, 778-784 (1994). 10.1002/mrm.v32:6 (Pubitemid 24371180)
    • (1994) Magnetic Resonance in Medicine , vol.32 , Issue.6 , pp. 778-784
    • Wong, S.T.S.1    Roos, M.S.2
  • 43
    • 34250176150 scopus 로고    scopus 로고
    • Hybrid diffusion imaging
    • DOI 10.1016/j.neuroimage.2007.02.050, PII S1053811907001693
    • Y. C. Wu and A. L. Alexander, Hybrid diffusion imaging., Neuroimage 36, 617-629 (2007). 10.1016/j.neuroimage.2007.02.050 (Pubitemid 46907619)
    • (2007) NeuroImage , vol.36 , Issue.3 , pp. 617-629
    • Wu, Y.-C.1    Alexander, A.L.2
  • 44
  • 45
    • 84902364821 scopus 로고    scopus 로고
    • Optimal approaches to diffusion MRI acquisition
    • in, edited by D. K. Jones (Oxford, New York)
    • D. K. Jones, Optimal approaches to diffusion MRI acquisition., in Diffusion MRI: Theory, Methods, and Applications, edited by, D. K. Jones, (Oxford, New York, 2010), pp. 250-271.
    • (2010) Diffusion MRI: Theory, Methods, and Applications , pp. 250-271
    • Jones, D.K.1
  • 46
    • 85027231258 scopus 로고    scopus 로고
    • A simple scheme for generating nearly uniform distribution of antipodally symmetric points on the unit sphere
    • (in press)
    • C. G. Koay, A simple scheme for generating nearly uniform distribution of antipodally symmetric points on the unit sphere., Journal of Computational Science (in press).
    • Journal of Computational Science
    • Koay, C.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.