메뉴 건너뛰기




Volumn 55, Issue 2, 2011, Pages 532-544

Segmentation of fiber tracts based on an accuracy analysis on diffusion tensor software phantoms

Author keywords

Brain; Diffusion tensor imaging; Fiber tracking; Fuzzy segmentation; Noise; Software model

Indexed keywords

ACCURACY; ALGORITHM; ANISOTROPY; ARCUATE FASCICULUS; ARTICLE; COMPUTER PROGRAM; COMPUTER SIMULATION; CONTROLLED STUDY; DIFFUSION TENSOR IMAGING; FUZZY SYSTEM; NERVE TRACT; NOISE; OPTICAL RESOLUTION; PHANTOM; PRIORITY JOURNAL; PYRAMIDAL TRACT;

EID: 79551577532     PISSN: 10538119     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2010.12.069     Document Type: Article
Times cited : (18)

References (49)
  • 1
    • 0035178887 scopus 로고    scopus 로고
    • Theoretical analysis of the effects of noise on diffusion tensor imaging
    • Anderson A. Theoretical analysis of the effects of noise on diffusion tensor imaging. Magn. Reson. Med. 2001, 46:1174-1188.
    • (2001) Magn. Reson. Med. , vol.46 , pp. 1174-1188
    • Anderson, A.1
  • 2
    • 22044439126 scopus 로고    scopus 로고
    • Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
    • Assaf Y., Basser P.J. Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain. Neuroimage 2005, 27:48-58.
    • (2005) Neuroimage , vol.27 , pp. 48-58
    • Assaf, Y.1    Basser, P.J.2
  • 3
    • 7544245274 scopus 로고    scopus 로고
    • New modeling and experimental framework to characterize hindered and restricted water diffusion in brain white matter
    • Assaf Y., Freidlin R.Z., Rohde G.K., Basser P.J. New modeling and experimental framework to characterize hindered and restricted water diffusion in brain white matter. Magn. Reson. Med. 2004, 52:965-978.
    • (2004) Magn. Reson. Med. , vol.52 , pp. 965-978
    • Assaf, Y.1    Freidlin, R.Z.2    Rohde, G.K.3    Basser, P.J.4
  • 5
    • 0002564748 scopus 로고    scopus 로고
    • Quantifying errors in fiber-tract direction and diffusion tensor field maps resulting from MR noise
    • Basser P. Quantifying errors in fiber-tract direction and diffusion tensor field maps resulting from MR noise. Proc. Int. Soc. Magn. Reson. Med. 1997, 1740.
    • (1997) Proc. Int. Soc. Magn. Reson. Med. , pp. 1740
    • Basser, P.1
  • 6
    • 0000541553 scopus 로고    scopus 로고
    • Fiber-tractography via diffusion tensor MRI (DT-MRI)
    • Basser P. Fiber-tractography via diffusion tensor MRI (DT-MRI). Proc. Int. Soc. Magn. Reson. Med. 1998, 1226.
    • (1998) Proc. Int. Soc. Magn. Reson. Med. , pp. 1226
    • Basser, P.1
  • 7
    • 0028154030 scopus 로고
    • MR diffusion tensor spectroscopy and imaging
    • Basser P., Mattiello J., LeBihan D. MR diffusion tensor spectroscopy and imaging. Biophys. J. 1994, 66:259-267.
    • (1994) Biophys. J. , vol.66 , pp. 259-267
    • Basser, P.1    Mattiello, J.2    LeBihan, D.3
  • 10
    • 3242766019 scopus 로고    scopus 로고
    • Diffusion anisotropy in subcortical white matter and cortical gray matter: changes with aging and the role of CSF-suppression
    • Bhagat Y.A., Beaulieu C. Diffusion anisotropy in subcortical white matter and cortical gray matter: changes with aging and the role of CSF-suppression. Magn. Reson. Imaging 2004, 20:216-227.
    • (2004) Magn. Reson. Imaging , vol.20 , pp. 216-227
    • Bhagat, Y.A.1    Beaulieu, C.2
  • 11
    • 33846043073 scopus 로고    scopus 로고
    • Variance of estimated DTI-derived parameters via first-order perturbation methods
    • Chang L.C., Koay C., Pierpaoli C., Basser P. Variance of estimated DTI-derived parameters via first-order perturbation methods. Magn. Reson. Med. 2007, 57:141-149.
    • (2007) Magn. Reson. Med. , vol.57 , pp. 141-149
    • Chang, L.C.1    Koay, C.2    Pierpaoli, C.3    Basser, P.4
  • 14
    • 33747151020 scopus 로고    scopus 로고
    • Newton methods for nonlinear problems
    • volume35 of Springer Series in Computational Mathematics, Springer, Berlin, Germany
    • Deuflhard P. Newton methods for nonlinear problems. Affine Invariance and Adaptive Algorithms 2004, volume35 of Springer Series in Computational Mathematics, Springer, Berlin, Germany.
    • (2004) Affine Invariance and Adaptive Algorithms
    • Deuflhard, P.1
  • 16
    • 0036335676 scopus 로고    scopus 로고
    • Fiber tracking from DTI using linear state space models: detectability of the pyramidal tract
    • Gössl C., Fahrmeir L., Pütz B., Auer L., Auer D. Fiber tracking from DTI using linear state space models: detectability of the pyramidal tract. Neuroimage 2002, 16:378-388.
    • (2002) Neuroimage , vol.16 , pp. 378-388
    • Gössl, C.1    Fahrmeir, L.2    Pütz, B.3    Auer, L.4    Auer, D.5
  • 17
    • 0028839871 scopus 로고
    • The Rician distribution of noisy MRI data
    • Gudbjartsson H., Patz S. The Rician distribution of noisy MRI data. Magn. Reson. Med. 1995, 34:910-914.
    • (1995) Magn. Reson. Med. , vol.34 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 19
    • 0000074076 scopus 로고
    • The estimation of second-order tensors, with related tests and designs
    • Hext G. The estimation of second-order tensors, with related tests and designs. Biometrika 1963, 50:353-357.
    • (1963) Biometrika , vol.50 , pp. 353-357
    • Hext, G.1
  • 21
    • 79551590114 scopus 로고    scopus 로고
    • ICBM DTI-81 Atlas Project URL
    • ICBM DTI-81 Atlas Project URL. http://www.loni.ucla.edu/ICBM/Downloads/Downloads_DTI-81.shtml.
  • 22
    • 79551599032 scopus 로고    scopus 로고
    • IEEE Vis.Contest, Image Data, Case 1
    • IEEE Vis. Contest Image Data, Case 1. http://viscontest.sdsc.edu/2010/.
  • 24
    • 33645875326 scopus 로고    scopus 로고
    • Analytically exact correction scheme for signal extraction from noisy magnitude MR signals
    • Koay C., Basser P. Analytically exact correction scheme for signal extraction from noisy magnitude MR signals. J. Magn. Reson. 2006, 179:477-482.
    • (2006) J. Magn. Reson. , vol.179 , pp. 477-482
    • Koay, C.1    Basser, P.2
  • 25
    • 33747872177 scopus 로고    scopus 로고
    • A unifying theoretical and algorithmic framework for least squares methods of estimation in diffusion tensor imaging
    • Koay C., Chang L.C., Carew J., Pierpaoli C., Basser P. A unifying theoretical and algorithmic framework for least squares methods of estimation in diffusion tensor imaging. J. Magn. Reson. 2006, 182:115-125.
    • (2006) J. Magn. Reson. , vol.182 , pp. 115-125
    • Koay, C.1    Chang, L.C.2    Carew, J.3    Pierpaoli, C.4    Basser, P.5
  • 26
    • 34547591228 scopus 로고    scopus 로고
    • Error propagation framework for diffusion tensor imaging via diffusion tensor representations
    • Koay C., Chang L.C., Pierpaoli C., Basser P. Error propagation framework for diffusion tensor imaging via diffusion tensor representations. IEEE Trans. Med. Imaging 2007, 26:1017-1034.
    • (2007) IEEE Trans. Med. Imaging , vol.26 , pp. 1017-1034
    • Koay, C.1    Chang, L.C.2    Pierpaoli, C.3    Basser, P.4
  • 27
    • 44449114653 scopus 로고    scopus 로고
    • The elliptical cone of uncertainty and its normalized measures in diffusion tensor imaging
    • Koay C., Nevo U., Chang L.C., Pierpaoli C., Basser P. The elliptical cone of uncertainty and its normalized measures in diffusion tensor imaging. IEEE Trans. Med. Imaging 2008, 27:834-846.
    • (2008) IEEE Trans. Med. Imaging , vol.27 , pp. 834-846
    • Koay, C.1    Nevo, U.2    Chang, L.C.3    Pierpaoli, C.4    Basser, P.5
  • 29
    • 0036868732 scopus 로고    scopus 로고
    • Diffusion tensor fiber tracking of human brain connectivity: acquisition methods, reliability analysis and biological results
    • Lori N., Akbudak E., Shimony J., Cull T., Snyder A., Guillory R., Conturo T. Diffusion tensor fiber tracking of human brain connectivity: acquisition methods, reliability analysis and biological results. NMR Biomed. 2002, 15:493-515.
    • (2002) NMR Biomed. , vol.15 , pp. 493-515
    • Lori, N.1    Akbudak, E.2    Shimony, J.3    Cull, T.4    Snyder, A.5    Guillory, R.6    Conturo, T.7
  • 31
    • 0033007902 scopus 로고    scopus 로고
    • Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging
    • Mori S., Crain B., Chacko V., Van Zijl P. Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging. Ann. Neurol. 1999, 45:265-269.
    • (1999) Ann. Neurol. , vol.45 , pp. 265-269
    • Mori, S.1    Crain, B.2    Chacko, V.3    Van Zijl, P.4
  • 33
    • 0025274778 scopus 로고
    • Signal-to-noise efficiency in magnetic resonance imaging
    • Parker D., Gullberg G. Signal-to-noise efficiency in magnetic resonance imaging. Med. Phys. 1990, 17:250-257.
    • (1990) Med. Phys. , vol.17 , pp. 250-257
    • Parker, D.1    Gullberg, G.2
  • 34
    • 0036557913 scopus 로고    scopus 로고
    • Estimating distributed anatomical connectivity using fast marching methods and diffusion tensor imaging
    • Parker G., Wheeler-Kingshott C., Barker G. Estimating distributed anatomical connectivity using fast marching methods and diffusion tensor imaging. IEEE Trans. Med. Imaging 2002, 21:505-512.
    • (2002) IEEE Trans. Med. Imaging , vol.21 , pp. 505-512
    • Parker, G.1    Wheeler-Kingshott, C.2    Barker, G.3
  • 36
    • 0029908076 scopus 로고    scopus 로고
    • Toward a quantitative assessment of diffusion anisotropy
    • Pierpaoli C., Basser P. Toward a quantitative assessment of diffusion anisotropy. Magn. Reson. Med. 1996, 36:893-906.
    • (1996) Magn. Reson. Med. , vol.36 , pp. 893-906
    • Pierpaoli, C.1    Basser, P.2
  • 38
    • 79551589305 scopus 로고    scopus 로고
    • Spatial HARDI: improved visualization of complex white matter architecture with Bayesian spatial regularization
    • Raj A., Hess C., Mukherjee P. Spatial HARDI: improved visualization of complex white matter architecture with Bayesian spatial regularization. Neuroimage 2010.
    • (2010) Neuroimage
    • Raj, A.1    Hess, C.2    Mukherjee, P.3
  • 39
    • 84943347235 scopus 로고
    • Sequential operations in digital picture processing
    • Rosenfeld A.J.P. Sequential operations in digital picture processing. J. ACM 1966, 13:471-494.
    • (1966) J. ACM , vol.13 , pp. 471-494
    • Rosenfeld, A.J.P.1
  • 40
    • 35048867519 scopus 로고    scopus 로고
    • Level set and region based surface propagation for diffusion tensor MRI segmentation
    • Rousson M., Lenglet C., Deriche R. Level set and region based surface propagation for diffusion tensor MRI segmentation. Proc. ECCV Workshops CVAMIA and MMBIA 2004, 123-134.
    • (2004) Proc. ECCV Workshops CVAMIA and MMBIA , pp. 123-134
    • Rousson, M.1    Lenglet, C.2    Deriche, R.3
  • 43
    • 0036210185 scopus 로고    scopus 로고
    • Limitations and requirements of diffusion tensor fiber tracking: an assessment using simulations
    • Tournier J.D., Calamante F., King M., Gadian D., Connelly A. Limitations and requirements of diffusion tensor fiber tracking: an assessment using simulations. Magn. Reson. Med. 2002, 47:701-708.
    • (2002) Magn. Reson. Med. , vol.47 , pp. 701-708
    • Tournier, J.D.1    Calamante, F.2    King, M.3    Gadian, D.4    Connelly, A.5
  • 46
    • 79551582089 scopus 로고    scopus 로고
    • Tractography segmentation using hierarchical Dirichlet processes mixture model
    • Wang X., Grimson W., Westin C.F. Tractography segmentation using hierarchical Dirichlet processes mixture model. Neuroimage 2010.
    • (2010) Neuroimage
    • Wang, X.1    Grimson, W.2    Westin, C.F.3
  • 47
    • 0041737567 scopus 로고    scopus 로고
    • Automatic segmentation of thalamic nuclei from diffusion tensor magnetic resonance imaging
    • Wiegell M., Tuch D., Larson H., Wedeen V. Automatic segmentation of thalamic nuclei from diffusion tensor magnetic resonance imaging. Neuroimage 2003, 19:391-402.
    • (2003) Neuroimage , vol.19 , pp. 391-402
    • Wiegell, M.1    Tuch, D.2    Larson, H.3    Wedeen, V.4
  • 48
    • 33750249657 scopus 로고    scopus 로고
    • Segmentation of thalamic nuclei from DTI using spectral clustering
    • Ziyan U., Tuch D., Westin C.F. Segmentation of thalamic nuclei from DTI using spectral clustering. Proc. MICCAI 2006, 807-814.
    • (2006) Proc. MICCAI , pp. 807-814
    • Ziyan, U.1    Tuch, D.2    Westin, C.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.