메뉴 건너뛰기




Volumn 17, Issue 1 PART 1, 2008, Pages

Model predictive control of glucose concentration in subjects with type 1 diabetes: An in silico trial

Author keywords

Biomedical system modeling, simulation and visualization; Control of physiological and clinical variables; Dynamics and control

Indexed keywords

BIOMEDICAL SYSTEM MODELING, SIMULATION AND VISUALIZATION; CONTINUOUS GLUCOSE MONITORING; CONTROL ALGORITHMS; DIABETIC PATIENT; DYNAMICS AND CONTROL; FEED-FORWARD; GLUCOSE CONCENTRATION; GLUCOSE METABOLISM; IN-SILICO; IN-SILICO MODELS; INSULIN DELIVERY; LINEAR OUTPUT FEEDBACK; NONLINEAR MODEL PREDICTIVE CONTROL; TYPE 1 DIABETES; VIRTUAL PATIENTS;

EID: 79961017820     PISSN: 14746670     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.3182/20080706-5-KR-1001.2518     Document Type: Conference Paper
Times cited : (23)

References (14)
  • 1
    • 14844351848 scopus 로고    scopus 로고
    • A critical assessment of algorithms and challanges in the development of a closed-loop artificial pancreas
    • B. W. Bequette. A critical assessment of algorithms and challanges in the development of a closed-loop artificial pancreas. Diabetes Technology & Therapeutics, 7:28-47, 1998.
    • (1998) Diabetes Technology & Therapeutics , vol.7 , pp. 28-47
    • Bequette, B.W.1
  • 5
    • 33746630272 scopus 로고    scopus 로고
    • Model-based blood glucose control for type 1 diabetes via parametric programming
    • DOI 10.1109/TBME.2006.878075, 1658142
    • P. Dua, F. J. Doyle III, and E. N. Pistikopoulos. Model-based blood glucose control for type 1 diabetes via parametric programming. IEEE Transactions on Biomedical Engineering, 53:1478-1491, 2006. (Pubitemid 44150259)
    • (2006) IEEE Transactions on Biomedical Engineering , vol.53 , Issue.8 , pp. 1478-1491
    • Dua, P.1    Doyle III, F.J.2    Pistikopoulos, E.N.3
  • 6
    • 33645051466 scopus 로고    scopus 로고
    • Continuous glucose monitoring and closed-loop systems
    • R. Hovorka. Continuous glucose monitoring and closed-loop systems. Diabetic Medicine, 23:1-12, 2005.
    • (2005) Diabetic Medicine , vol.23 , pp. 1-12
    • Hovorka, R.1
  • 7
    • 34248162815 scopus 로고    scopus 로고
    • The artificial pancreas: How sweet engineering will solve bitter problems
    • D. C. Klono. The artificial pancreas: How sweet engineering will solve bitter problems. J. of Diabetes Science and Technology, 1:72-81, 2007.
    • (2007) J. of Diabetes Science and Technology , vol.1 , pp. 72-81
    • Klono, D.C.1
  • 8
    • 31144461926 scopus 로고    scopus 로고
    • Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: Mathematical methods and clinical application
    • B. P. Kovatchev, W. L. Clarke, M. Breton, K. Brayman, and A. McCall. Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: Mathematical methods and clinical application. Diabetes Technol Ther., 7:842-862, 2005.
    • (2005) Diabetes Technol Ther. , vol.7 , pp. 842-862
    • Kovatchev, B.P.1    Clarke, W.L.2    Breton, M.3    Brayman, K.4    McCall, A.5
  • 10
    • 3042686485 scopus 로고    scopus 로고
    • Model predictive control of continuous-time nonlinear systems with piecewise constant control
    • L. Magni and R. Scattolini. Model predictive control of continuous-time nonlinear systems with piecewise constant control. IEEE Trans. on Automatic Control, 49:900-906, 2004.
    • (2004) IEEE Trans. on Automatic Control , vol.49 , pp. 900-906
    • Magni, L.1    Scattolini, R.2
  • 12
    • 0033876326 scopus 로고    scopus 로고
    • Constrained model predictive control: Stability and optimality
    • DOI 10.1016/S0005-1098(99)00214-9
    • D. Q. Mayne, J. B. Rawlings, C. V. Rao, and P. O. M. Scokaert. Constrained model predictive control: Stability and optimality. Automatica, 36:789-814, 2000. (Pubitemid 30587683)
    • (2000) Automatica , vol.36 , Issue.6 , pp. 789-814
    • Mayne, D.Q.1    Rawlings, J.B.2    Rao, C.V.3    Scokaert, P.O.M.4
  • 13
    • 33747056641 scopus 로고    scopus 로고
    • Evaluation of the effect of gain on the meal response of an automated closed-loop insulin delivery system
    • A. E. Panteleon, M. Loutseiko, G. M. Steil, and K. Rebrin. Evaluation of the effect of gain on the meal response of an automated closed-loop insulin delivery system. Diabetes, 55:1995-2000, 2006.
    • (2006) Diabetes , vol.55 , pp. 1995-2000
    • Panteleon, A.E.1    Loutseiko, M.2    Steil, G.M.3    Rebrin, K.4
  • 14
    • 0019479343 scopus 로고
    • Effects of plasma glucose concentration on glucose utilization and glucose clearance in normal man
    • C. A. Verdonk, R. A Rizza, and J. E. Gerich. Effects of plasma glucose concentration on glucose utilization and glucose clearance in normal man. Diabetes, 30:535-537, 1981. (Pubitemid 11023377)
    • (1981) Diabetes , vol.30 , Issue.6 , pp. 535-537
    • Verdonk, C.A.1    Rizza, R.A.2    Gerich, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.