메뉴 건너뛰기




Volumn 61, Issue 6, 2010, Pages 513-523

A new design paradigm for the development of custom-fit soft sockets for lower limb prostheses

Author keywords

Custom fit products; Human centric soft product design; Physics based modeling for soft products; Prosthesis development process

Indexed keywords

ARTIFICIAL LIMBS; MEDICAL IMAGING; PRODUCT DESIGN; REVERSE ENGINEERING; VIRTUAL REALITY;

EID: 79961003366     PISSN: 01663615     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.compind.2010.03.008     Document Type: Article
Times cited : (80)

References (33)
  • 3
    • 0035706069 scopus 로고    scopus 로고
    • State-of-the-art methods for geometric and biomechanical assessments of residual limbs: A review
    • Y.P. Zheng, F.T. Mak Arthur, K.L. Leung Aaron, M. Phil, State-of-the-art methods for geometric and biomechanical assessments of residual limbs: a review, Journal of Rehabilitation Research and Development 38 (5) (2001) 487-504. (Pubitemid 34118827)
    • (2001) Journal of Rehabilitation Research and Development , vol.38 , Issue.5 , pp. 487-504
    • Zheng, Y.P.1    Mak, A.F.T.2    Leung, A.K.L.3
  • 4
    • 20444482498 scopus 로고    scopus 로고
    • Consistency and accuracy of measurement of lower-limb amputee anthropometrics
    • DOI 10.1682/JRRD.2004.05.0054
    • M.D. Geil, Consistency and accuracy of measurement of lower-limb amputee anthropemetrics, Journal of Prosthetics and Orthotics 42 (2) (2005) 131-140. (Pubitemid 40814197)
    • (2005) Journal of Rehabilitation Research and Development , vol.42 , Issue.2 , pp. 131-140
    • Geil, M.D.1
  • 10
    • 10444245805 scopus 로고    scopus 로고
    • 3D reconstruction of the structure of a residual limb for customising the design of a prosthetic socket
    • S. Zheng, W. Zhao, B. Lu, 3D reconstruction of the structure of a residual limb for customising the design of a prosthetic socket, Medical Engineering & Physics 27 (2005) 67-74.
    • (2005) Medical Engineering & Physics , vol.27 , pp. 67-74
    • Zheng, S.1    Zhao, W.2    Lu, B.3
  • 13
    • 84859441860 scopus 로고    scopus 로고
    • Toward modelling of a suturing task
    • Halifax, NS, June 11-13
    • M. LeDuc, J. Dill, Toward modelling of a suturing task, in: Graphics Interface 2003, Halifax, NS, June 11-13, 2003.
    • (2003) Graphics Interface 2003
    • Leduc, M.1    Dill, J.2
  • 14
    • 3242655551 scopus 로고    scopus 로고
    • Load transfer mechanics between trans-tibial prosthetic socket and residual limb - Dynamic effects
    • DOI 10.1016/j.jbiomech.2003.12.024, PII S0021929003004871
    • W.C.C. Lee, M. Zhang, X. Jia, Load transfer mechanics between trans-tibial prosthetic socket and residual limb dynamic effects, Journal of Biomechanics 37 (2004) 1371-1377. (Pubitemid 38953246)
    • (2004) Journal of Biomechanics , vol.37 , Issue.9 , pp. 1371-1377
    • Jia, X.1    Zhang, M.2    Lee, W.C.C.3
  • 15
    • 4744352767 scopus 로고    scopus 로고
    • Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket
    • DOI 10.1016/j.medengphy.2004.04.010, PII S1350453304000773
    • W.C.C. Lee, M. Zhang, X. Jia, J.T.M. Cheung, Finite element modelling of the contact interface between trans-tibial residual limb and prosthetic socket, Medical Engineering & Physics 26 (2004) 655-662. (Pubitemid 39311071)
    • (2004) Medical Engineering and Physics , vol.26 , Issue.8 , pp. 655-662
    • Lee, W.C.C.1    Zhang, M.2    Jia, X.3    Cheung, J.T.M.4
  • 16
    • 31144446701 scopus 로고    scopus 로고
    • The quasi-static response of compliant prosthetic sockets for transtibial amputees using finite element methods
    • DOI 10.1016/j.medengphy.2005.04.019, PII S1350453305001013
    • M.C. Faustini, R.R. Neptune, R.H. Crawford, The quasi-static response of compliant prosthetic sockets for transtibial amputees using finite elements methods, Medical Engineering & Physics 28 (2006) 114-121. (Pubitemid 43129593)
    • (2006) Medical Engineering and Physics , vol.28 , Issue.2 , pp. 114-121
    • Faustini, M.C.1    Neptune, R.R.2    Crawford, R.H.3
  • 17
    • 0038580764 scopus 로고    scopus 로고
    • Nonlinear elastic material property estimation of lower extremity residual limb tissues
    • DOI 10.1109/TNSRE.2003.810436
    • E. Tönuk, M.B. Silver-Thorn, Nonlinear elastic material property estimation of lower extremity residual limb tissues, IEEE Transaction on Neural Systems and Rehabilitation Engineering 11 (1) (2003) 43-53. (Pubitemid 36613251)
    • (2003) IEEE Transactions on Neural Systems and Rehabilitation Engineering , vol.11 , Issue.1 , pp. 43-53
    • Tonuk, E.1    Silver-Thorn, M.B.2
  • 18
    • 2442607619 scopus 로고    scopus 로고
    • Nonlinear viscoelastic material property estimation of lower extremity residual limb tissues
    • DOI 10.1115/1.1695575
    • E. Tönuk, M.B. Silver-Thorn, Nonlinear viscoelastic material estimation of lower extremity residual limb tissues, Journal of Biomechanical Engineering 126 (2) (2004) 289-300. (Pubitemid 38621143)
    • (2004) Journal of Biomechanical Engineering , vol.126 , Issue.2 , pp. 289-300
    • Tonuk, E.1    Silver-Thorn, M.B.2
  • 20
    • 85030578038 scopus 로고    scopus 로고
    • Cooperative work in medicine: Linking together distributed expertise in hip-prostheses development and surgical planning
    • CA, USA
    • S. Filippi, C. Bandera, M. Felice, Cooperative work in medicine: linking together distributed expertise in hip-prostheses development and surgical planning, in: ISPE-CE2001, Advances in Concurrent Engineering, CA, USA, 2001.
    • (2001) ISPE-CE2001, Advances in Concurrent Engineering
    • Filippi, S.1    Bandera, C.2    Felice, M.3
  • 21
    • 0030940692 scopus 로고    scopus 로고
    • Value of a synthetic osseus model obtained by stereolithography for preoperative planning correction of a complex femural deformity caused by fibrous dysplasia
    • H. Migaud, B. Cortet, R. Assaker, Value of a synthetic osseus model obtained by stereolithography for preoperative planning correction of a complex femural deformity caused by fibrous dysplasia, Revue Chirurgie Orthopedique et Reparatrice de l Appareil Moteur (1997) 83-156.
    • (1997) Revue Chirurgie Orthopedique et Reparatrice de L Appareil Moteur , pp. 83-156
    • Migaud, H.1    Cortet, B.2    Assaker, R.3
  • 22
    • 78649842222 scopus 로고    scopus 로고
    • Automation of prosthetic socket design and fabrication using computer-aided-design/computer-aided-engineering and rapid prototyping techniques
    • Singapore
    • T.K. Cheng, P.L.V. Sin, T.K. Fye, L.S. Lin, Automation of prosthetic socket design and fabrication using computer-aided-design/computer-aided- engineering and rapid prototyping techniques, in: First National Symposium on Prosthetics and Orthotics, Singapore, 1998.
    • (1998) First National Symposium on Prosthetics and Orthotics
    • Cheng, T.K.1    Sin, P.L.V.2    Fye, T.K.3    Lin, L.S.4
  • 23
    • 0032351290 scopus 로고    scopus 로고
    • Sthererolithography and prosthetic test socket manufacture: A cost/benefit analysis
    • D. Freeman, L. Wontorcik, Sthererolithography and prosthetic test socket manufacture: a cost/benefit analysis, Journal of Prothestics and Orthotics 10(1) (1998) 17.
    • (1998) Journal of Prothestics and Orthotics , vol.10 , Issue.1 , pp. 17
    • Freeman, D.1    Wontorcik, L.2
  • 24
    • 84859438832 scopus 로고    scopus 로고
    • A preliminary investigation into the development of 3-D printing of prosthetic sockets
    • N. Herbert, D. Simpson, W.D. Spence, W. Ion, A preliminary investigation into the development of 3-D printing of prosthetic sockets, Medical Engineering and Physics 26 (8) (2005) 655-662.
    • (2005) Medical Engineering and Physics , vol.26 , Issue.8 , pp. 655-662
    • Herbert, N.1    Simpson, D.2    Spence, W.D.3    Ion, W.4
  • 30
    • 14044254112 scopus 로고    scopus 로고
    • Design automation for customized apparel products
    • DOI 10.1016/j.cad.2004.08.007, PII S0010448504001599
    • C.C.L. Wang, Y. Wang, M.M.F. Yuen, Design automation for customized apparel products, Computer-Aided Design 37 (7) (2005) 675-691. (Pubitemid 40276688)
    • (2005) CAD Computer Aided Design , vol.37 , Issue.7 , pp. 675-691
    • Wang, C.C.L.1    Wang, Y.2    Yuen, M.M.F.3
  • 31
    • 4544320334 scopus 로고    scopus 로고
    • Parameterization and parametric design of mannequins
    • C.C.L. Wang, Parameterization and parametric design of mannequins, Computer-Aided Design 37 (1) (2005) 83-98.
    • (2005) Computer-Aided Design , vol.37 , Issue.1 , pp. 83-98
    • Wang, C.C.L.1
  • 32
    • 77957220335 scopus 로고    scopus 로고
    • The role of simulation tools to innovate the prosthesis socket design process
    • D.T. Pham, E.E. Eldukhri, A.J. Soroka (Eds.) , Whittles Publishing, ISBN: 978-1904445-52-4
    • F.S. Frillici, P. Rissone, C. Rizzi, F. Rotini, The role of simulation tools to innovate the prosthesis socket design process, in: D.T. Pham, E.E. Eldukhri, A.J. Soroka (Eds.), Intelligent Production Machines and Systems, Whittles Publishing, 2008, pp. 612-619, ISBN: 978-1904445-52-4.
    • (2008) Intelligent Production Machines and Systems , pp. 612-619
    • Frillici, F.S.1    Rissone, P.2    Rizzi, C.3    Rotini, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.