메뉴 건너뛰기




Volumn 51, Issue 8, 2011, Pages 857-869

A fast tissue stiffness-dependent elastography for HIFU-induced lesions inspection

Author keywords

Displacement; High intensity focused ultrasound (HIFU); Strain; Tissue stiffness distribution; Ultrasound elastography

Indexed keywords

ALGORITHM PARAMETERS; AXIAL RESOLUTIONS; BOVINE LIVER; COMPREHENSIVE PERFORMANCE; COMPUTATIONAL COSTS; COMPUTATIONAL TIME; CONTRAST TO NOISE RATIO; DISPLACEMENT; DISPLACEMENT ESTIMATION; ELASTOGRAPHY; HIGH INTENSITY FOCUSED ULTRASOUND; HIGH TIME EFFICIENCY; IN-VITRO; OPTIMUM PARAMETERS; PERFORMANCE PARAMETERS; PHANTOM EXPERIMENT; RADIOFREQUENCY SIGNALS; REAL TIME; SIGNAL TO NOISE; TIME EFFICIENCIES; TISSUE MODELS; TISSUE STIFFNESS DISTRIBUTION; ULTRASOUND ELASTOGRAPHY;

EID: 79960698889     PISSN: 0041624X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultras.2011.03.011     Document Type: Article
Times cited : (20)

References (45)
  • 1
    • 4644312297 scopus 로고    scopus 로고
    • 500-Element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls
    • DOI 10.1002/mrm.20118
    • K. Hynynen, G.T. Clement, N. McDannold, N. Vykhodtseva, R. King, P.J. White, S. Vitek, and F.A. Jolesz 500-element ultrasound phased array system for noninvasive focal surgery of the brain: a preliminary rabbit study with ex vivo human skulls Magn. Reson. Med. 52 2004 100 107 (Pubitemid 39295261)
    • (2004) Magnetic Resonance in Medicine , vol.52 , Issue.1 , pp. 100-107
    • Hynynen, K.1    Clement, G.T.2    McDannold, N.3    Vykhodtseva, N.4    King, R.5    White, P.J.6    Vitek, S.7    Jolesz, F.A.8
  • 5
    • 0842287225 scopus 로고    scopus 로고
    • A randomised clinical trial of high-intensity focused ultrasound ablation for the treatment of patients with localised breast cancer
    • DOI 10.1038/sj.bjc.6601411
    • F. Wu, Z.B. Wang, Y.D. Cao, W.Z. Chen, J. Bai, J.Z. Zou, and H. Zhu A randomized clinical trial of high-intensity focused ultrasound ablation for the treatment of patients with localized breast cancer Brit. J. Cancer 89 2003 2227 2233 (Pubitemid 38168004)
    • (2003) British Journal of Cancer , vol.89 , Issue.12 , pp. 2227-2233
    • Wu, F.1    Wang, Z.-B.2    Cao, Y.-De.3    Chen, W.-Z.4    Bai, J.5    Zou, J.-Z.6    Zhu, H.7
  • 6
    • 0242523861 scopus 로고    scopus 로고
    • Preliminary experience using high intensity focused ultrasound for the treatment of patients with advanced stage renal malignancy
    • DOI 10.1097/01.ju.0000097123.34790.70
    • F. Wu, Z. Wang, and W. Chen Preliminary experience using high intensity focused ultrasound for the treatment of patients with advanced stage renal malignancy J. Urol. 170 2003 2237 2240 (Pubitemid 37413966)
    • (2003) Journal of Urology , vol.170 , Issue.6 , pp. 2237-2240
    • Wu, F.1    Wang, Z.-B.2    Chen, W.-Z.3    Bai, J.4    Zhu, H.5    Qiao, T.-Y.6
  • 10
    • 33751333444 scopus 로고    scopus 로고
    • Therapeutic application of ultrasound
    • G. ter Haar Therapeutic application of ultrasound Prog. Biophys. Mol. Biol. 93 1-3 2007 111 129
    • (2007) Prog. Biophys. Mol. Biol. , vol.93 , Issue.13 , pp. 111-129
    • Ter Haar, G.1
  • 12
    • 1842611811 scopus 로고    scopus 로고
    • High intensity focused ultrasound ablation of kidney guided by MRI
    • DOI 10.1016/j.ultrasmedbio.2003.10.018, PII S0301562903011529
    • C. Damianou, M. Pavlou, O. Velev, K. Kyriakou, and M. Trimikliniotis High intensity focused ultrasound ablation of kidney guided by MRI Ultrasound Med. Biol. 30 3 2004 397 404 (Pubitemid 38456707)
    • (2004) Ultrasound in Medicine and Biology , vol.30 , Issue.3 , pp. 397-404
    • Damianou, C.1    Pavlou, M.2    Velev, O.3    Kyriakou, K.4    Trimikliniotis, M.5
  • 13
    • 33745221857 scopus 로고    scopus 로고
    • Magnetic resonance-guided focused ultrasound surgery of breast cancer: Reliability and effectiveness
    • H. Furusawa, K. Namba, and S. Thomsen Magnetic resonance-guided focused ultrasound surgery of breast cancer: reliability and effectiveness J. Am. Coll. Surg. 203 2006 54 63
    • (2006) J. Am. Coll. Surg. , vol.203 , pp. 54-63
    • Furusawa, H.1    Namba, K.2    Thomsen, S.3
  • 15
    • 33645656754 scopus 로고    scopus 로고
    • A method to synchronize high-intensity, focused ultrasound with an arbitrary ultrasound imager
    • N.R. Owen, M.R. Bailey, J. Hossack, and L.A. Crum A method to synchronize high-intensity, focused ultrasound with an arbitrary ultrasound imager IEEE Trans. Ultrason. Ferroelect. Freq. Contr. 53 3 2006 645 650
    • (2006) IEEE Trans. Ultrason. Ferroelect. Freq. Contr. , vol.53 , Issue.3 , pp. 645-650
    • Owen, N.R.1    Bailey, M.R.2    Hossack, J.3    Crum, L.A.4
  • 16
    • 0035057522 scopus 로고    scopus 로고
    • Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging
    • DOI 10.1016/S0301-5629(00)00279-9, PII S0301562900002799
    • S. Vaezy, X.G. Shi, R.W. Martin, E. Chi, P.I. Nelson, M.R. Bailey, and L.A. Crum Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging Ultrasound Med. Biol. 27 2001 33 42 (Pubitemid 32280229)
    • (2001) Ultrasound in Medicine and Biology , vol.27 , Issue.1 , pp. 33-42
    • Vaezy, S.1    Shi, X.2    Martin, R.W.3    Chi, E.4    Nelson, P.I.5    Bailey, M.R.6    Crum, L.A.7
  • 17
    • 0030291626 scopus 로고    scopus 로고
    • Noninvasive real-time multipoint temperature control for ultrasound phased array treatments
    • PII S0885301096078586
    • R. Seip, P. VanBaren, C. Cain, and E. Ebbini Non-invasive real-time multipoint temperature control for ultrasound phased array treatments IEEE Trans. Ultrason. Ferroelect. Freq. Contr. 43 1996 1063 1073 (Pubitemid 126781108)
    • (1996) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control , vol.43 , Issue.6 , pp. 1063-1073
    • Seip, R.1
  • 19
    • 67349090939 scopus 로고    scopus 로고
    • Temperature measurement by thermal strain imaging with diagnostic power ultrasound, with potential for thermal index determination
    • H.D. Liang, L.X. Zhou, P. N.T. Wells, and M. Halliwell Temperature measurement by thermal strain imaging with diagnostic power ultrasound, with potential for thermal index determination Ultrasound Med. Biol. 35 5 2009 773 780
    • (2009) Ultrasound Med. Biol. , vol.35 , Issue.5 , pp. 773-780
    • Liang, H.D.1    Zhou, L.X.2    Wells, P.N.T.3    Halliwell, M.4
  • 20
    • 33845676131 scopus 로고    scopus 로고
    • Monitoring imaging of lesions induced by high intensity focused ultrasound based on differential ultrasonic attenuation and integrated backscatter estimation
    • DOI 10.1016/j.ultrasmedbio.2006.07.034, PII S0301562906017765
    • H. Zhong, M.X. Wan, Y.F. Jiang, and S.P. Wang Monitoring imaging of lesions induced by high intensity focused ultrasound based on differential ultrasonic attenuation and integrated backscatter estimation Ultrasound Med. Biol. 33 1 2007 82 94 (Pubitemid 44959330)
    • (2007) Ultrasound in Medicine and Biology , vol.33 , Issue.1 , pp. 82-94
    • Zhong, H.1    Wan, M.-X.2    Jiang, Y.-F.3    Wang, S.-P.4
  • 21
    • 0030792572 scopus 로고    scopus 로고
    • Dependence of ultrasonic attenuation and absorption in dog soft tissues on temperature and thermal dose
    • DOI 10.1121/1.419737
    • C.A. Damianou, N.T. Sanghvi, F.J. Fry, and R. Maass-moreno Dependence of ultrasonic attenuation and absorption in dog soft tissues on temperature and thermal dose J. Acoust. Soc. Am. 102 1997 628 634 (Pubitemid 27300542)
    • (1997) Journal of the Acoustical Society of America , vol.102 , Issue.1 , pp. 628-634
    • Damianou, C.A.1    Sanghvi, N.T.2    Fry, F.J.3    Maass-Moreno, R.4
  • 22
    • 74449091314 scopus 로고    scopus 로고
    • Dynamic changes of integrated backscatter, attenuation coefficient and bubble activities during high-intensity focused ultrasound (HIFU) treatment
    • S.Y. Zhang, M.X. Wan, H. Zhong, C. Xu, Z.Z. Liao, H.Q. Liu, and S.P. Wang Dynamic changes of integrated backscatter, attenuation coefficient and bubble activities during high-intensity focused ultrasound (HIFU) treatment Ultrasound Med. Biol. 35 11 2009 1828 1844
    • (2009) Ultrasound Med. Biol. , vol.35 , Issue.11 , pp. 1828-1844
    • Zhang, S.Y.1    Wan, M.X.2    Zhong, H.3    Xu, C.4    Liao, Z.Z.5    Liu, H.Q.6    Wang, S.P.7
  • 23
    • 33845714776 scopus 로고    scopus 로고
    • Nonlinear absorption in biological tissue for high intensity focused ultrasound
    • X.Z. Liu, J.L. Li, X.F. Gong, and D. Zhang Nonlinear absorption in biological tissue for high intensity focused ultrasound Ultrasonics 44 Suppl 1 2006 e27 e30
    • (2006) Ultrasonics , vol.44 , Issue.SUPPL. 1
    • Liu, X.Z.1    Li, J.L.2    Gong, X.F.3    Zhang, D.4
  • 24
    • 0032809552 scopus 로고    scopus 로고
    • Detection of high-intensity focused ultrasound liver lesions using dynamic elastometry
    • X. Shi, R.W. Martin, D. Rouseff, S. Vaezy, and L.A. Crum Detection of high-intensity focused ultrasound liver lesions using dynamic elastometry Ultrason. Imaging 21 2 1999 107 126 (Pubitemid 29367678)
    • (1999) Ultrasonic Imaging , vol.21 , Issue.2 , pp. 107-126
    • Shi, X.1    Martin, R.W.2    Rouseff, D.3    Vaezy, S.4    Crum, L.A.5
  • 25
    • 0038356879 scopus 로고    scopus 로고
    • The use of ultrasound-stimulated acoustic emission in the monitoring of modulus changes with temperature
    • E. Konofagou, J. Thieman, and K. Hynynen The use of ultrasound-stimulated acoustic emission in the monitoring of modulus changes with temperature Ultrasonics 41 5 2003 337 345
    • (2003) Ultrasonics , vol.41 , Issue.5 , pp. 337-345
    • Konofagou, E.1    Thieman, J.2    Hynynen, K.3
  • 27
    • 41049096808 scopus 로고    scopus 로고
    • Harmonic motion imaging for focused ultrasound (HMIFU): A fully integrated technique for sonication and monitoring of thermal ablation in tissues
    • DOI 10.1088/0031-9155/53/6/018, PII S0031915508632273
    • C. Maleke, and E.E. Konofagou Harmonic motion imaging for focused ultrasound (HMIFU): a fully integrated technique for sonication and monitoring of thermal ablation in tissues Phys. Med. Biol. 53 2008 1773 1793 (Pubitemid 351423010)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.6 , pp. 1773-1793
    • Maleke, C.1    Konofagou, E.E.2
  • 28
    • 0025806883 scopus 로고
    • Elastography: A quantitative method for imaging the elasticity of biological tissues
    • J. Ophir, I. Cespedes, H. Ponnekanti, Y. Yazdi, and X. Li Elastography: a quantitative method for imaging the elasticity of biological tissues Ultrason. Imaging 13 2 1991 111 134
    • (1991) Ultrason. Imaging , vol.13 , Issue.2 , pp. 111-134
    • Ophir, J.1    Cespedes, I.2    Ponnekanti, H.3    Yazdi, Y.4    Li, X.5
  • 29
    • 0032931389 scopus 로고    scopus 로고
    • The feasibility of elastographic visualization of HIFU-induced thermal lesions in soft tissues
    • DOI 10.1016/S0301-5629(98)00184-7, PII S0301562998001847
    • F. Kallel, R.J. Stafford, R.E. Price, R. Righetti, J. Ophir, and J.D. Hazle The feasibility of elastographic visualization of HIFU-induced thermal lesions in soft tissues. Image-guided high-intensity focused ultrasound Ultrasound Med. Biol. 25 4 1999 641 647 (Pubitemid 29226949)
    • (1999) Ultrasound in Medicine and Biology , vol.25 , Issue.4 , pp. 641-647
    • Kallel, F.1    Stafford, R.J.2    Price, R.E.3    Righetti, R.4    Ophir, J.5    Hazle, J.D.6
  • 31
    • 27744493451 scopus 로고    scopus 로고
    • Elastography for the follow-up of high-intensity focused ultrasound prostate cancer treatment: Initial comparison with MRI
    • DOI 10.1016/j.ultrasmedbio.2005.06.013, PII S0301562905002607
    • L. Curiel, R. Souchon, O. Rouviere, A. Gelet, and J.Y. Chapelon Elastography for the follow-up of high-intensity focused ultrasound prostate cancer treatment: initial comparison with MRI Ultrasound Med. Biol. 31 11 2005 1461 1468 (Pubitemid 41606261)
    • (2005) Ultrasound in Medicine and Biology , vol.31 , Issue.11 , pp. 1461-1468
    • Curiel, L.1    Souchon, R.2    Rouviere, O.3    Gelet, A.4    Chapelon, J.Y.5
  • 33
    • 1342324769 scopus 로고    scopus 로고
    • Ultrasound elastography based on multiscale estimations of regularized displacement fields
    • Pellet-Barakat, F. Frouin, M.F. Insana, and A. Herment Ultrasound elastography based on multiscale estimations of regularized displacement fields IEEE Trans. Med. Imaging 23 2 2004 3 163
    • (2004) IEEE Trans. Med. Imaging , vol.23 , Issue.2 , pp. 3-163
    • Pellet-Barakat1    Frouin, F.2    Insana, M.F.3    Herment, A.4
  • 34
    • 33845651235 scopus 로고    scopus 로고
    • Improvement of elastographic displacement estimation using a two-step cross-correlation method
    • H. Chen, H. Shi, and T. Varghese Improvement of elastographic displacement estimation using a two-step cross-correlation method Ultrasound Med. Biol. 33 1 2007 48 57
    • (2007) Ultrasound Med. Biol. , vol.33 , Issue.1 , pp. 48-57
    • Chen, H.1    Shi, H.2    Varghese, T.3
  • 36
    • 4644366111 scopus 로고    scopus 로고
    • Axial strain calculation using a low-pass digital differentiator in ultrasound elastography
    • J.W. Luo, J. Bai, P. He, and K. Ying Axial strain calculation using a low-pass digital differentiator in ultrasound elastography IEEE Trans. Ultrason. Ferroelect. Freq. Contr. 51 9 2004 1119 1127
    • (2004) IEEE Trans. Ultrason. Ferroelect. Freq. Contr. , vol.51 , Issue.9 , pp. 1119-1127
    • Luo, J.W.1    Bai, J.2    He, P.3    Ying, K.4
  • 38
    • 0032127040 scopus 로고    scopus 로고
    • An analysis of elastographic contrast-to-noise ratio
    • DOI 10.1016/S0301-5629(98)00047-7, PII S0301562998000477
    • T. Varghese, and J. Ophir An analysis of elastographic contrast-to-noise ratio Ultrasound Med. Biol. 24 b 1998 915 924 (Pubitemid 28347972)
    • (1998) Ultrasound in Medicine and Biology , vol.24 , Issue.6 , pp. 915-924
    • Varghese, T.1    Ophir, J.2
  • 40
    • 0029937329 scopus 로고    scopus 로고
    • Fundamental limitations on the contrast-transfer efficiency in elastography: An analytic study
    • DOI 10.1016/0301-5629(95)02079-9
    • F. Kallel, M. Bertrand, and J. Ophir Fundamental limitation on the contrast-transfer efficiency in elastography: an analytic study Ultrasound Med. Biol. 22 4 1996 463 470 (Pubitemid 26166938)
    • (1996) Ultrasound in Medicine and Biology , vol.22 , Issue.4 , pp. 463-470
    • Kallel, F.1    Bertrand, M.2    Ophir, J.3
  • 44
    • 0034874752 scopus 로고    scopus 로고
    • Contrast-transfer efficiency for continuously varying tissue moduli: Simulation and phantom validation
    • DOI 10.1016/S0301-5629(01)00411-2, PII S0301562901004112
    • F. Kallel, C.D. Prihoda, and J. Ophir Contrast-transfer efficiency for continuously varying tissue moduli: simulation and phantom validation Ultrasound Med. Biol. 27 2001 1115 1125 (Pubitemid 32807734)
    • (2001) Ultrasound in Medicine and Biology , vol.27 , Issue.8 , pp. 1115-1125
    • Kallel, F.1    Prihoda, C.D.2    Ophir, J.3
  • 45
    • 0037710390 scopus 로고    scopus 로고
    • Trade-offs between the axial resolution and the signal-to-noise ratio in elastography
    • DOI 10.1016/S0301-5629(03)00037-1
    • S. Srinivasan, R. Righetti, and J. Ophir Trade-offs between the axial resolution and the signal-to-noise ratio in elastography Ultrasound Med. Biol. 29 2003 847 866 (Pubitemid 36808637)
    • (2003) Ultrasound in Medicine and Biology , vol.29 , Issue.6 , pp. 847-866
    • Srinivasan, S.1    Righetti, R.2    Ophir, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.