메뉴 건너뛰기




Volumn 53, Issue 3, 2006, Pages 645-650

A method to synchronize high-intensity, focused ultrasound with an arbitrary ultrasound imager

Author keywords

[No Author keywords available]

Indexed keywords

ARBITRARY ULTRASOUND IMAGER; FOCUSED ULTRASOUND (HIPU) THERAPY; TISSUE PHANTOMS; ULTRASOUND IMAGING;

EID: 33645656754     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2006.1610574     Document Type: Article
Times cited : (25)

References (7)
  • 1
    • 0041852671 scopus 로고    scopus 로고
    • Physical mechanisms of the therapeutic effect of ultrasound: (A review)
    • |1] M, R. Bailey, V. A. Khokhlova, O. A. Sapozhnikov, S. G. Kargl, and L. A. Crum, "Physical mechanisms of the therapeutic effect of ultrasound: (A review)," Acoust. Phys., vol. 49, no. 4, pp. 369-388, 2003.
    • (2003) Acoust. Phys. , vol.49 , Issue.4 , pp. 369-388
    • Bailey, M.R.1    Khokhlova, V.A.2    Sapozhnikov, O.A.3    Kargl, S.G.4    Crum, L.A.5
  • 3
    • 0035057522 scopus 로고    scopus 로고
    • Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging
    • Jan.
    • S. Vaezy, X. Shi, R. W. Martin, E. Chi, P. I. Nelson, M. R. Bailey, and L. A. Crum, "Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging," Ultrasound Med. Biol., vol. 27, pp. 33-42, Jan. 2001.
    • (2001) Ultrasound Med. Biol. , vol.27 , pp. 33-42
    • Vaezy, S.1    Shi, X.2    Martin, R.W.3    Chi, E.4    Nelson, P.I.5    Bailey, M.R.6    Crum, L.A.7
  • 5
    • 14744276163 scopus 로고    scopus 로고
    • Ultrasonic temperature imaging for guiding focused ultrasound surgery: Effect of angle between imaging beam and therapy beam
    • Mar.
    • N. R. Miller, K. M. Bograchev, and J. C. Miller, "Ultrasonic temperature imaging for guiding focused ultrasound surgery: Effect of angle between imaging beam and therapy beam," Ultrasound Med. Biol, vol. 31, pp. 401-413, Mar. 2005.
    • (2005) Ultrasound Med. Biol , vol.31 , pp. 401-413
    • Miller, N.R.1    Bograchev, K.M.2    Miller, J.C.3
  • 7
    • 0035730974 scopus 로고    scopus 로고
    • Development and characterization of an innovative synthetic tissue-mimicking material for high-intensity focused ultrasound (HIFU) exposures
    • C. Lafon, P. J. Kaczkowski, S. Vaezy, M. Nobel, and O. A. Sapozhnikov, "Development and characterization of an innovative synthetic tissue-mimicking material for high-intensity focused ultrasound (HIFU) exposures," in Proc. IEEE Ultrason. Symp., 2001, pp. 1295-1298.
    • (2001) Proc. IEEE Ultrason. Symp. , pp. 1295-1298
    • Lafon, C.1    Kaczkowski, P.J.2    Vaezy, S.3    Nobel, M.4    Sapozhnikov, O.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.