메뉴 건너뛰기




Volumn 15, Issue 4, 2011, Pages

High mixed venous oxygen saturation levels do not exclude fluid responsiveness in critically ill septic patients

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; CENTRAL VENOUS PRESSURE; CRITICALLY ILL PATIENT; FLUID RESUSCITATION; HEART INDEX; HEART RATE; HEART STROKE VOLUME; HEMODYNAMICS; HUMAN; INTENSIVE CARE UNIT; MAJOR CLINICAL STUDY; MEAN ARTERIAL PRESSURE; OBSERVATIONAL STUDY; OXYGEN SATURATION; PRIORITY JOURNAL; PULMONARY ARTERY OCCLUSION PRESSURE; RECEIVER OPERATING CHARACTERISTIC; SEPSIS; THERAPY EFFECT; UNIVERSITY HOSPITAL; BLOOD; BLOOD PRESSURE; CRITICAL ILLNESS; FLUID THERAPY; HEART OUTPUT; MIDDLE AGED; PATHOPHYSIOLOGY; RETROSPECTIVE STUDY; VEIN; VERY ELDERLY;

EID: 79960662382     PISSN: 13648535     EISSN: 1466609X     Source Type: Journal    
DOI: 10.1186/10326     Document Type: Article
Times cited : (44)

References (23)
  • 1
    • 7944230298 scopus 로고    scopus 로고
    • Fluids reverse the early lipopolysaccharide-induced albumin leakage in rodent mesenteric venules
    • 10.1007/s00134-004-2385-3, 15258732
    • Anning PB, Finney SJ, Singh S, Winlove CP, Evans TW. Fluids reverse the early lipopolysaccharide-induced albumin leakage in rodent mesenteric venules. Intensive Care Med 2004, 30:1944-1949. 10.1007/s00134-004-2385-3, 15258732.
    • (2004) Intensive Care Med , vol.30 , pp. 1944-1949
    • Anning, P.B.1    Finney, S.J.2    Singh, S.3    Winlove, C.P.4    Evans, T.W.5
  • 2
    • 0021813725 scopus 로고
    • Fluid loading increases oxygen consumption in septic patients with lactic acidosis
    • Haupt MT, Gilbert EM, Carlson RW. Fluid loading increases oxygen consumption in septic patients with lactic acidosis. Am Rev Respir Dis 1985, 131:912-916.
    • (1985) Am Rev Respir Dis , vol.131 , pp. 912-916
    • Haupt, M.T.1    Gilbert, E.M.2    Carlson, R.W.3
  • 3
    • 0032437998 scopus 로고    scopus 로고
    • Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension
    • 10.1097/00000542-199812000-00007, 9856704
    • Tavernier B, Makhotine O, Lebuffe G, Dupont J, Scherpereel P. Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 1998, 89:1313-1321. 10.1097/00000542-199812000-00007, 9856704.
    • (1998) Anesthesiology , vol.89 , pp. 1313-1321
    • Tavernier, B.1    Makhotine, O.2    Lebuffe, G.3    Dupont, J.4    Scherpereel, P.5
  • 6
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence
    • 10.1378/chest.121.6.2000, 12065368
    • Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 2002, 121:2000-2008. 10.1378/chest.121.6.2000, 12065368.
    • (2002) Chest , vol.121 , pp. 2000-2008
    • Michard, F.1    Teboul, J.L.2
  • 7
    • 8444228185 scopus 로고    scopus 로고
    • Fluid resuscitation in severe sepsis and septic shock: an evidence-based review
    • 10.1097/01.CCM.0000142984.44321.A4, 15542955
    • Vincent JL, Gerlach H. Fluid resuscitation in severe sepsis and septic shock: an evidence-based review. Crit Care Med 2004, 32:S451-S454. 10.1097/01.CCM.0000142984.44321.A4, 15542955.
    • (2004) Crit Care Med , vol.32
    • Vincent, J.L.1    Gerlach, H.2
  • 8
    • 33646567765 scopus 로고    scopus 로고
    • Fluid challenge revisited
    • 10.1097/01.CCM.0000214677.76535.A5, 16557164
    • Vincent JL, Weil MH. Fluid challenge revisited. Crit Care Med 2006, 34:1333-1337. 10.1097/01.CCM.0000214677.76535.A5, 16557164.
    • (2006) Crit Care Med , vol.34 , pp. 1333-1337
    • Vincent, J.L.1    Weil, M.H.2
  • 9
    • 0021735922 scopus 로고
    • Continuous monitoring of mixed venous oxygen saturation in hemodynamically unstable patients
    • 10.1378/chest.86.5.753, 6488915
    • Birman H, Haq A, Hew E, Aberman A. Continuous monitoring of mixed venous oxygen saturation in hemodynamically unstable patients. Chest 1984, 86:753-756. 10.1378/chest.86.5.753, 6488915.
    • (1984) Chest , vol.86 , pp. 753-756
    • Birman, H.1    Haq, A.2    Hew, E.3    Aberman, A.4
  • 10
    • 70350475284 scopus 로고    scopus 로고
    • Hemodynamic monitoring in sepsis
    • ix, 10.1016/j.ccc.2009.08.006, 19892254
    • Casserly B, Read R, Levy MM. Hemodynamic monitoring in sepsis. Crit Care Clin 2009, 25:803-823. ix, 10.1016/j.ccc.2009.08.006, 19892254.
    • (2009) Crit Care Clin , vol.25 , pp. 803-823
    • Casserly, B.1    Read, R.2    Levy, M.M.3
  • 12
    • 0031735051 scopus 로고    scopus 로고
    • Use of the SOFA score to assess the incidence of organ dysfunction/failure in intensive care units: results of a multicenter, prospective study. Working group on "sepsis-related problems" of the European Society of Intensive Care Medicine
    • 10.1097/00003246-199811000-00016, 9824069
    • Vincent JL, de Mendonça A, Cantraine F, Moreno R, Takala J, Suter PM, Sprung CL, Colardyn F, Blecher S. Use of the SOFA score to assess the incidence of organ dysfunction/failure in intensive care units: results of a multicenter, prospective study. Working group on "sepsis-related problems" of the European Society of Intensive Care Medicine. Crit Care Med 1998, 26:1793-1800. 10.1097/00003246-199811000-00016, 9824069.
    • (1998) Crit Care Med , vol.26 , pp. 1793-1800
    • Vincent, J.L.1    de Mendonça, A.2    Cantraine, F.3    Moreno, R.4    Takala, J.5    Suter, P.M.6    Sprung, C.L.7    Colardyn, F.8    Blecher, S.9
  • 13
    • 0032412276 scopus 로고    scopus 로고
    • Continuous cardiac output and mixed venous oxygen saturation monitoring
    • 10.1016/S0883-9441(98)90006-5, 9869547
    • Cariou A, Monchi M, Dhainaut JF. Continuous cardiac output and mixed venous oxygen saturation monitoring. J Crit Care 1998, 13:198-213. 10.1016/S0883-9441(98)90006-5, 9869547.
    • (1998) J Crit Care , vol.13 , pp. 198-213
    • Cariou, A.1    Monchi, M.2    Dhainaut, J.F.3
  • 14
    • 36048933359 scopus 로고    scopus 로고
    • Hemodynamic optimization of sepsis-induced tissue hypoperfusion
    • 10.1186/cc4829, 17352796
    • Zanotti Cavazzoni SL, Dellinger RP. Hemodynamic optimization of sepsis-induced tissue hypoperfusion. Crit Care 2006, 10(Suppl 3):S2. 10.1186/cc4829, 17352796.
    • (2006) Crit Care , vol.10 , Issue.SUPPL. 3
    • Zanotti Cavazzoni, S.L.1    Dellinger, R.P.2
  • 15
    • 18344363998 scopus 로고    scopus 로고
    • Let us use the pulmonary artery catheter correctly and only when we need it
    • 10.1097/01.CCM.0000163238.64905.56, 15891346
    • Pinsky MR, Vincent JL. Let us use the pulmonary artery catheter correctly and only when we need it. Crit Care Med 2005, 33:1119-1122. 10.1097/01.CCM.0000163238.64905.56, 15891346.
    • (2005) Crit Care Med , vol.33 , pp. 1119-1122
    • Pinsky, M.R.1    Vincent, J.L.2
  • 16
    • 0028872009 scopus 로고
    • A trial of goal-oriented hemodynamic therapy in critically ill patients. SvO2 Collaborative Group
    • 10.1056/NEJM199510193331601, 7675044
    • Gattinoni L, Brazzi L, Pelosi P, Latini R, Tognoni G, Pesenti A, Fumagalli R. A trial of goal-oriented hemodynamic therapy in critically ill patients. SvO2 Collaborative Group. N Engl J Med 1995, 333:1025-1032. 10.1056/NEJM199510193331601, 7675044.
    • (1995) N Engl J Med , vol.333 , pp. 1025-1032
    • Gattinoni, L.1    Brazzi, L.2    Pelosi, P.3    Latini, R.4    Tognoni, G.5    Pesenti, A.6    Fumagalli, R.7
  • 17
    • 0029980699 scopus 로고    scopus 로고
    • Maximizing oxygen delivery in critically ill patients: a methodologic appraisal of the evidence
    • 10.1097/00003246-199603000-00025, 8625644
    • Heyland DK, Cook DJ, King D, Kernerman P, Brun-Buisson C. Maximizing oxygen delivery in critically ill patients: a methodologic appraisal of the evidence. Crit Care Med 1996, 24:517-524. 10.1097/00003246-199603000-00025, 8625644.
    • (1996) Crit Care Med , vol.24 , pp. 517-524
    • Heyland, D.K.1    Cook, D.J.2    King, D.3    Kernerman, P.4    Brun-Buisson, C.5
  • 18
    • 33845958648 scopus 로고    scopus 로고
    • Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge
    • 10.1097/01.CCM.0000249851.94101.4F, 17080001
    • Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, Teboul JL. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med 2007, 35:64-68. 10.1097/01.CCM.0000249851.94101.4F, 17080001.
    • (2007) Crit Care Med , vol.35 , pp. 64-68
    • Osman, D.1    Ridel, C.2    Ray, P.3    Monnet, X.4    Anguel, N.5    Richard, C.6    Teboul, J.L.7
  • 19
    • 0023785261 scopus 로고
    • Biventricular performance during volume loading in patients with early septic shock, with emphasis on the right ventricle: a combined hemodynamic and radionuclide study
    • 10.1016/0002-8703(88)90256-6, 3394612
    • Schneider AJ, Teule GJ, Groeneveld AB, Nauta J, Heidendal GA, Thijs LG. Biventricular performance during volume loading in patients with early septic shock, with emphasis on the right ventricle: a combined hemodynamic and radionuclide study. Am Heart J 1988, 116:103-112. 10.1016/0002-8703(88)90256-6, 3394612.
    • (1988) Am Heart J , vol.116 , pp. 103-112
    • Schneider, A.J.1    Teule, G.J.2    Groeneveld, A.B.3    Nauta, J.4    Heidendal, G.A.5    Thijs, L.G.6
  • 20
    • 0020960312 scopus 로고
    • Optimum left heart filling pressure during fluid resuscitation of patients with hypovolemic and septic shock
    • 10.1097/00003246-198303000-00003, 6831886
    • Packman MI, Rackow EC. Optimum left heart filling pressure during fluid resuscitation of patients with hypovolemic and septic shock. Crit Care Med 1983, 11:165-169. 10.1097/00003246-198303000-00003, 6831886.
    • (1983) Crit Care Med , vol.11 , pp. 165-169
    • Packman, M.I.1    Rackow, E.C.2
  • 21
    • 68949199480 scopus 로고    scopus 로고
    • Bench-to-bedside review: the initial hemodynamic resuscitation of the septic patient according to Surviving Sepsis Campaign guidelines-does one size fit all?
    • 10.1186/cc6979, 2592726, 18828870
    • Perel A. Bench-to-bedside review: the initial hemodynamic resuscitation of the septic patient according to Surviving Sepsis Campaign guidelines-does one size fit all?. Crit Care 2008, 12:223. 10.1186/cc6979, 2592726, 18828870.
    • (2008) Crit Care , vol.12 , pp. 223
    • Perel, A.1
  • 22
    • 0037348762 scopus 로고    scopus 로고
    • Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care
    • Bendjelid K, Romand JA. Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care. Intensive Care Med 2003, 29:352-360.
    • (2003) Intensive Care Med , vol.29 , pp. 352-360
    • Bendjelid, K.1    Romand, J.A.2
  • 23
    • 34547837379 scopus 로고    scopus 로고
    • Hemodynamic goals in randomized clinical trials in patients with sepsis: a systematic review of the literature
    • 10.1186/cc5948, 2206433, 17584921
    • Sevransky JE, Nour S, Susla GM, Needham DM, Hollenberg S, Pronovost P. Hemodynamic goals in randomized clinical trials in patients with sepsis: a systematic review of the literature. Crit Care 2007, 11:R67. 10.1186/cc5948, 2206433, 17584921.
    • (2007) Crit Care , vol.11
    • Sevransky, J.E.1    Nour, S.2    Susla, G.M.3    Needham, D.M.4    Hollenberg, S.5    Pronovost, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.