메뉴 건너뛰기




Volumn 50, Issue 6, 2011, Pages 838-850

Emerging technologies in proton therapy

Author keywords

[No Author keywords available]

Indexed keywords

PROTON;

EID: 79960539223     PISSN: 0284186X     EISSN: 1651226X     Source Type: Journal    
DOI: 10.3109/0284186X.2011.582513     Document Type: Conference Paper
Times cited : (104)

References (66)
  • 1
    • 0017722986 scopus 로고
    • Flattening of proton dose distributions for large field radiotherapy
    • DOI 10.1118/1.594317
    • Koehler AM, Schneider RJ, Sisterson JM. Flattening of pro-ton dose distributions for large fi eld radiotherapy Med Phys 1977;4:297-301. (Pubitemid 8147899)
    • (1977) Medical Physics , vol.4 , Issue.4 , pp. 297-301
    • Koehler, A.M.1    Schneider, R.J.2    Sisterson, J.M.3
  • 3
    • 0028891524 scopus 로고
    • The 200 MeV proton therapy project at PSI: Conceptual design and practical realization
    • Pedroni E, Bacher E, Blattmann H, Boehringer T, Coray A, Lomax AJ. The 200 MeV proton therapy project at PSI: Conceptual design and practical realization. Med Phys 1995; 22:37-53.
    • (1995) Med Phys , vol.22 , pp. 37-53
    • Pedroni, E.1    Bacher, E.2    Blattmann, H.3    Boehringer, T.4    Coray, A.5    Lomax, A.J.6
  • 6
    • 0032949514 scopus 로고    scopus 로고
    • Intensity modulated methods for proton therapy
    • Lomax AJ. Intensity modulated methods for proton therapy. Phys Med Biol 1999;44:185-205.
    • (1999) Phys Med Biol , vol.44 , pp. 185-205
    • Lomax, A.J.1
  • 13
    • 39049126842 scopus 로고    scopus 로고
    • Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2: The potential effects of inter-fraction and inter-field motions
    • DOI 10.1088/0031-9155/53/4/015, PII S0031915508549589
    • Lomax AJ. Intensity modulated proton therapy and its sen-sitivity to treatment uncertainties 2: The potential effects of inter-fraction and inter-fi eld motions. Phys Med Biol 2008;53:1043-56. (Pubitemid 351238122)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.4 , pp. 1043-1056
    • Lomax, A.J.1
  • 14
    • 70349581605 scopus 로고    scopus 로고
    • Breathing interplay effects during proton beam scanning: Simulation and statistical analysis
    • Seco J, Robertson D, Trofi mov A, Pagansetti H. Breathing interplay effects during proton beam scanning: Simulation and statistical analysis. Phys Med Biol 2009;54:N283-94.
    • (2009) Phys Med Biol , vol.54
    • Seco, J.1    Robertson, D.2    Trofimov, A.3    Pagansetti, H.4
  • 16
    • 16444381177 scopus 로고    scopus 로고
    • 4D Monte Carlo simulation of proton beam scanning: Modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry
    • DOI 10.1088/0031-9155/50/5/020
    • Paganetti H, Jiang H, Trofi mov A. 4D Monte Carlo simulation of proton beam scanning: Modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry. Phys Med Biol 2005;50: 983-90. (Pubitemid 40477318)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.5 , pp. 983-990
    • Paganetti, H.1    Jiang, H.2    Trofimov, A.3
  • 17
    • 70449120374 scopus 로고    scopus 로고
    • Tumour tracking with scanned proton beams: Assessing the accuracy and practicalities
    • van de Water S, Kreuger R, Zenklusen S, Hug EB, Lomax AJ. Tumour tracking with scanned proton beams: Assessing the accuracy and practicalities. Phys Med Biol 2009;54: 6549-63.
    • (2009) Phys Med Biol , vol.54 , pp. 6549-63
    • Van De Water, S.1    Kreuger, R.2    Zenklusen, S.3    Hug, E.B.4    Lomax, A.J.5
  • 20
    • 69549099881 scopus 로고    scopus 로고
    • Speed and accuracy of a beam tracking system for treatment of moving targets with scanned ion beams
    • Saito N, Bert C, Chaudri N, Gemmel A, Schardt D, Durante M, et al. Speed and accuracy of a beam tracking system for treatment of moving targets with scanned ion beams. Phys Med Biol 2009;54:4849-62.
    • (2009) Phys Med Biol , vol.54 , pp. 4849-62
    • Saito, N.1    Bert, C.2    Chaudri, N.3    Gemmel, A.4    Schardt, D.5    Durante, M.6
  • 21
    • 84973120236 scopus 로고    scopus 로고
    • Beam delivery systems for particle radiation therapy
    • Schippers JM. Beam delivery systems for particle radiation therapy. Rev Acc Sci Tech 2009;2:179-200.
    • (2009) Rev Acc Sci Tech , vol.2 , pp. 179-200
    • Schippers, J.M.1
  • 22
    • 70350637692 scopus 로고    scopus 로고
    • Geant4 simulations of proton beam transport through a carbon or beryllium degrader and following beam line
    • van Goethem MJ, van der Meer R, Reist HW, Schippers JM. Geant4 simulations of proton beam transport through a carbon or beryllium degrader and following beam line. Phys Med Biol 2009;54:5831-46.
    • (2009) Phys Med Biol , vol.54 , pp. 5831-46
    • Van Goethem, M.J.1    Van Der Meer, R.2    Reist, H.W.3    Schippers, J.M.4
  • 24
    • 79960523475 scopus 로고    scopus 로고
    • Converging missions on cancer treatment at the Center for Proton Ther-apy (CPT)
    • Hug E, Timmermann B, Pedroni E, Meer D. Converging missions on cancer treatment at the Center for Proton Ther-apy (CPT). PSI, Villigen; 2008, pp 56-8.
    • (2008) PSI Villigen , pp. 56-8
    • Hug, E.1    Timmermann, B.2    Pedroni, E.3    Meer, D.4
  • 25
    • 0024916014 scopus 로고
    • Medical accelerator projects at Michigan state uni-versity. Proceedings of Particle Accelerator Conference, Chi-cago (Ill), USA, March 20-23
    • IEEE 1989
    • Blosser H, Burleigh R, Johnson D, Kuo T, Marti F, Vincent J, et al. Medical accelerator projects at Michigan state uni-versity. Proceedings of Particle Accelerator Conference, Chi-cago (Ill), USA, March 20-23, 1989. Accelerator Science and Technology. IEEE 1989;2:742-6.
    • (1989) Accelerator Science and Technology , vol.2 , pp. 742-6
    • Blosser, H.1    Burleigh, R.2    Johnson, D.3    Kuo, T.4    Marti, F.5    Vincent, J.6
  • 26
    • 0028307285 scopus 로고
    • A superconducting cyclotron for neutron radiation therapy
    • DOI 10.1118/1.597337
    • Maughan RL, Powers WE, Blosser HG. A superconducting cyclotron for neutron radiation therapy. Med Phys 1994; 21:779-85. (Pubitemid 24188127)
    • (1994) Medical Physics , vol.21 , Issue.6 , pp. 779-785
    • Maughan, R.L.1    Powers, W.E.2    Blosser, H.G.3
  • 28
    • 84856313829 scopus 로고    scopus 로고
    • Still River Systems Littleton (MA) USA Available from
    • Still River Systems, Littleton (MA), USA, 2011. Available from: http://www.nim.nih.gov/bsd/uniform-requirements.html.
    • (2011)
  • 29
    • 84856312931 scopus 로고    scopus 로고
    • IBA Louvain la Neauve Belgium 2011. Available from
    • IBA, Louvain la Neauve, Belgium, 2011. Available from: http://www.iba-protontherapy.com/proteus-one.
  • 32
    • 84856310332 scopus 로고    scopus 로고
    • Protvino (Moscow), Russia PROTOM Available from
    • Protvino (Moscow), Russia PROTOM 2010. Available from: http://www.protom.ru/
    • (2010)
  • 37
  • 38
    • 84973437037 scopus 로고    scopus 로고
    • Fixed fi eld alternating gradient accelerators
    • Craddock MK, Symon KR. Fixed fi eld alternating gradient accelerators. Rev Acc Sci Tech 2008;1:65-97.
    • (2008) Rev Acc Sci Tech , vol.1 , pp. 65-97
    • Craddock, M.K.1    Symon, K.R.2
  • 39
    • 84973120190 scopus 로고    scopus 로고
    • FFAGs as accelerators and beam delivery devices for ion cancer therapy
    • Trbojevic D. FFAGs as accelerators and beam delivery devices for ion cancer therapy. Rev Acc Sci Tech 2009;2:229-51.
    • (2009) Rev Acc Sci Tech , vol.2 , pp. 229-51
    • Trbojevic, D.1
  • 46
  • 47
    • 84973161574 scopus 로고    scopus 로고
    • Laser acceleration of ions for radiation therapy
    • Tajima T, Habs D, Yan X. Laser acceleration of ions for radiation therapy. Rev Acc Sci Tech 2009;2:201-28.
    • (2009) Rev Acc Sci Tech , vol.2 , pp. 201-28
    • Tajima, T.1    Habs, D.2    Yan, X.3
  • 51
    • 71049169722 scopus 로고    scopus 로고
    • Modifying proton fl uence spectra to gen-erate spread-out Bragg peaks with laser accelerated proton beams
    • Schell S, Wilkins JJ. Modifying proton fl uence spectra to gen-erate spread-out Bragg peaks with laser accelerated proton beams. Phys Med Biol 2009;54:N459-66.
    • (2009) Phys Med Biol , vol.54
    • Schell, S.1    Wilkins, J.J.2
  • 52
    • 38449101431 scopus 로고    scopus 로고
    • Radia-tion pressure acceleration of thin foils with circularly polar-ized laser pulses
    • 013021
    • Robinson APL, Zepf M, Kar S, Evans RG, Bellei C. Radia-tion pressure acceleration of thin foils with circularly polar-ized laser pulses. New J Phys 2008;10:013021, 1-13.
    • (2008) New J Phys , vol.10 , pp. 1-13
    • Apl, R.1    Zepf, M.2    Kar, S.3    Evans, R.G.4    Bellei, C.5
  • 53
    • 33646707534 scopus 로고    scopus 로고
    • Desktop accelerators going up?
    • Ledingham K. Desktop accelerators going up? Nature Phys 2006;2:11-2.
    • (2006) Nature Phys , vol.2 , pp. 11-2
    • Ledingham, K.1
  • 54
    • 33644633451 scopus 로고    scopus 로고
    • Point/Counterpoint Within the next decade conventional cyclotrons for proton radiotherapy will become obsolete and replaced by far less expensive machines using compact laser systems for the acceleration of the pro-tons
    • Ma CM, Maughan RL. Point/Counterpoint. Within the next decade conventional cyclotrons for proton radiotherapy will become obsolete and replaced by far less expensive machines using compact laser systems for the acceleration of the pro-tons. Med Phys 2006;33:571-3.
    • (2006) Med Phys , vol.33 , pp. 571-3
    • Ma, C.M.1    Maughan, R.L.2
  • 55
    • 34948879559 scopus 로고    scopus 로고
    • What will it take for laser driven proton accelerators to be applied to tumor therapy?
    • 8
    • Linz U, Alonso J. What will it take for laser driven proton accelerators to be applied to tumor therapy? Phys Rev ST Accel Beams 2007;10:094801-1:8.
    • (2007) Phys Rev ST Accel Beams , vol.10 , pp. 094801-1
    • Linz, U.1    Alonso, J.2
  • 57
    • 58149234209 scopus 로고    scopus 로고
    • Feasibility of MRI guided proton therapy: Magnetic fi eld dose effects
    • Raaymakers BW, Raaijmakers AJE, Lagendijk JJW Feasibility of MRI guided proton therapy: Magnetic fi eld dose effects. Phys Med Biol 2008;53:5615-22.
    • (2008) Phys Med Biol , vol.53 , pp. 5615-22
    • Raaymakers, B.W.1    Aje, R.2    Lagendijk, J.J.W.3
  • 58
    • 0028900136 scopus 로고
    • Proton radiography as a tool for quality control in proton therapy
    • Schneider U, Pedroni E. Proton radiography as a tool for quality control in proton therapy. Med Phys 1995;22:353.
    • (1995) Med Phys , vol.22 , pp. 353
    • Schneider, U.1    Pedroni, E.2
  • 60
    • 78149346507 scopus 로고    scopus 로고
    • Proton range verifi cation using a range probe: Defi nition of concept and initial analysis
    • Mumot M, Algranati C, Hartmann M, Schippers JM, Hug E, Lomax AJ. Proton range verifi cation using a range probe: Defi nition of concept and initial analysis. Phys Med Biol 2010;55:4771-82.
    • (2010) Phys Med Biol , vol.55 , pp. 4771-82
    • Mumot, M.1    Algranati, C.2    Hartmann, M.3    Schippers, J.M.4    Hug, E.5    Lomax, A.J.6
  • 64
    • 0038497895 scopus 로고    scopus 로고
    • A technique to sharpen the beam penumbra for Gamma Knife radiosurgery
    • DOI 10.1088/0031-9155/48/12/312, PII S0031915503597470
    • Guerrero M, Allen Li X, Ma L. A technique to sharpen the beam penumbra for Gamma Knife radiosurgery. Phys Med Biol 2003;48:1843-53. (Pubitemid 36805854)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.12 , pp. 1843-1853
    • Guerrero, M.1    Allen Li, X.2    Ma, L.3
  • 65
    • 34447321620 scopus 로고    scopus 로고
    • Evaluation of GAFCHROMIC EBT fi lm for CyberKnife dosimetry
    • Wilcox EE, Daskalov GM. Evaluation of GAFCHROMIC EBT fi lm for CyberKnife dosimetry. Med Phys 2007; 34:1967.
    • (2007) Med Phys , vol.34 , pp. 1967
    • Wilcox, E.E.1    Daskalov, G.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.