-
1
-
-
33845927591
-
Sensitization to nickel: etiology, epidemiology, immune reactions, prevention, and therapy
-
Hostynek J.J. Sensitization to nickel: etiology, epidemiology, immune reactions, prevention, and therapy. Rev Environ Health 2006, 21:253-280.
-
(2006)
Rev Environ Health
, vol.21
, pp. 253-280
-
-
Hostynek, J.J.1
-
2
-
-
41149083694
-
Detection of nickel sensitivity has increased in North American patch-test patients
-
Rietschel R.L., Fowler J.F., Warshaw E.M., et al. Detection of nickel sensitivity has increased in North American patch-test patients. Dermatitis 2008, 19:16-19.
-
(2008)
Dermatitis
, vol.19
, pp. 16-19
-
-
Rietschel, R.L.1
Fowler, J.F.2
Warshaw, E.M.3
-
6
-
-
0020662671
-
Potential toxicity from nickel contamination of intravenous fluids
-
Sunderman F.W. Potential toxicity from nickel contamination of intravenous fluids. Ann Clin Lab Sci 1983, 13:1-4.
-
(1983)
Ann Clin Lab Sci
, vol.13
, pp. 1-4
-
-
Sunderman, F.W.1
-
7
-
-
47249106421
-
Hypersensitivity reactions associated with endovascular devices
-
Honari G., Ellis S.G., Wilkoff B.L., Aronica M.A., Svensson L.G., Taylor J.S. Hypersensitivity reactions associated with endovascular devices. Contact Derm 2008, 59:7-22.
-
(2008)
Contact Derm
, vol.59
, pp. 7-22
-
-
Honari, G.1
Ellis, S.G.2
Wilkoff, B.L.3
Aronica, M.A.4
Svensson, L.G.5
Taylor, J.S.6
-
8
-
-
60849115562
-
Prevention of nickel allergy: the case for regulation?
-
Lu L.K., Warshaw E.M., Dunnick C.A. Prevention of nickel allergy: the case for regulation?. Dermatol Clin 2009, 27:155-161.
-
(2009)
Dermatol Clin
, vol.27
, pp. 155-161
-
-
Lu, L.K.1
Warshaw, E.M.2
Dunnick, C.A.3
-
9
-
-
77951689719
-
Validity of self-reported nickel allergy
-
Josefson A., Farm G., Meding B. Validity of self-reported nickel allergy. Contact Derm 2010, 62:289-293.
-
(2010)
Contact Derm
, vol.62
, pp. 289-293
-
-
Josefson, A.1
Farm, G.2
Meding, B.3
-
10
-
-
84856314469
-
-
Available at
-
Available at: http://www.orthopedicanalysis.com/metal-allergy/interpreting_metal_allergy_test.html.
-
-
-
-
11
-
-
74949099466
-
Nickel hypersensitivity: a clinical review and call to action
-
Schram S.E., Warshaw E.M., Laumann A. Nickel hypersensitivity: a clinical review and call to action. Int J Dermatol 2010, 49:115-125.
-
(2010)
Int J Dermatol
, vol.49
, pp. 115-125
-
-
Schram, S.E.1
Warshaw, E.M.2
Laumann, A.3
-
12
-
-
0345269973
-
Nickel release after implantation of the Amplatzer occluder
-
Ries M.W., Kampmann C., Rupprecht H.J., Hintereder G., Hafner G., Meyer J. Nickel release after implantation of the Amplatzer occluder. Am Heart J 2003, 145:737-741.
-
(2003)
Am Heart J
, vol.145
, pp. 737-741
-
-
Ries, M.W.1
Kampmann, C.2
Rupprecht, H.J.3
Hintereder, G.4
Hafner, G.5
Meyer, J.6
-
13
-
-
77049102900
-
Metal allergy: a review on exposures, penetration, genetics, prevalence, and clinical implications
-
Thyssen J.P., Menne T. Metal allergy: a review on exposures, penetration, genetics, prevalence, and clinical implications. Chem Res Toxicol 2010, 23:309-318.
-
(2010)
Chem Res Toxicol
, vol.23
, pp. 309-318
-
-
Thyssen, J.P.1
Menne, T.2
-
14
-
-
0034597889
-
Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
-
Koster R., Vieluf D., Kiehn M., et al. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet 2000, 356:1895-1897.
-
(2000)
Lancet
, vol.356
, pp. 1895-1897
-
-
Koster, R.1
Vieluf, D.2
Kiehn, M.3
-
15
-
-
36348952103
-
Nickel allergy in interatrial shunt device-based closure patients
-
Rigatelli G., Cardaioli P., Giordan M., et al. Nickel allergy in interatrial shunt device-based closure patients. Congenital Heart Dis 2007, 2:416-420.
-
(2007)
Congenital Heart Dis
, vol.2
, pp. 416-420
-
-
Rigatelli, G.1
Cardaioli, P.2
Giordan, M.3
-
16
-
-
72549118783
-
The association between metal allergy, total hip arthroplasty, and revision
-
Thyssen J.P., Jakobsen S.S., Engkilde K., Johansen J.D., Søballe K., Menné T. The association between metal allergy, total hip arthroplasty, and revision. Acta Orthop 2009, 80:646-652.
-
(2009)
Acta Orthop
, vol.80
, pp. 646-652
-
-
Thyssen, J.P.1
Jakobsen, S.S.2
Engkilde, K.3
Johansen, J.D.4
Søballe, K.5
Menné, T.6
-
17
-
-
0019627753
-
Surface corrosion of nitinol and stainless steel under clinical conditions
-
Edie J.W., Andreasen G.F., Zaytoun M.P. Surface corrosion of nitinol and stainless steel under clinical conditions. Angle Orthod 1981, 51:319-324.
-
(1981)
Angle Orthod
, vol.51
, pp. 319-324
-
-
Edie, J.W.1
Andreasen, G.F.2
Zaytoun, M.P.3
-
18
-
-
0025866290
-
Reduced frequency of nickel allergy upon oral nickel contact at an early age
-
Van Hoogstraten I.M., Andersen K.E., Von Blomberg B.M., et al. Reduced frequency of nickel allergy upon oral nickel contact at an early age. Clin Exp Immunol 1991, 85:441-445.
-
(1991)
Clin Exp Immunol
, vol.85
, pp. 441-445
-
-
Van Hoogstraten, I.M.1
Andersen, K.E.2
Von Blomberg, B.M.3
-
19
-
-
79960462912
-
-
Leaching analysis. Palo Alto, CA: Scientific Environmental Laboratories Inc; November 27, Data on file, Conceptus Corp.
-
Leaching analysis. Palo Alto, CA: Scientific Environmental Laboratories Inc; November 27, 2001. Data on file, Conceptus Corp.
-
(2001)
-
-
-
20
-
-
20544450832
-
Nickel contact allergy and menstrual cycle
-
Bonamonte D., Foti C., Antelmi A.R., et al. Nickel contact allergy and menstrual cycle. Contact Derm 2005, 52:309-313.
-
(2005)
Contact Derm
, vol.52
, pp. 309-313
-
-
Bonamonte, D.1
Foti, C.2
Antelmi, A.R.3
-
21
-
-
0025823461
-
Premenstrual exacerbation of nickel allergy
-
McLelland J., Lawrence C.M. Premenstrual exacerbation of nickel allergy. Br J Dermatol 1991, 125:83.
-
(1991)
Br J Dermatol
, vol.125
, pp. 83
-
-
McLelland, J.1
Lawrence, C.M.2
-
22
-
-
79960442715
-
Complications associated with Essure device: analysis after 4000 procedures
-
Arjona Berral J.E., Velasco Sanches E., Povedano Canizares B., Castillo R., Davalos S. Complications associated with Essure device: analysis after 4000 procedures. Gynecol Surg 2010, 7(suppl 1):S89.
-
(2010)
Gynecol Surg
, vol.7
, Issue.SUPPL. 1
-
-
Arjona Berral, J.E.1
Velasco Sanches, E.2
Povedano Canizares, B.3
Castillo, R.4
Davalos, S.5
-
23
-
-
84856306795
-
-
The use of the WHO-UMC system for standardized case causality assessment. Available at.
-
The use of the WHO-UMC system for standardized case causality assessment. Available at: http://www.who-umc.org/graphics/4409.pdf.
-
-
-
|