메뉴 건너뛰기




Volumn 690, Issue , 2011, Pages 491-494

Properties of sintered Mg alloys for biomedical applications

Author keywords

Biodegradable; Cytocompatibility; Magnesium; MgCa; Sintering

Indexed keywords

BONE; CALCIUM ALLOYS; COMPRESSION TESTING; MAGNESIUM; MEDICAL APPLICATIONS; METAL IMPLANTS; POWDER METALS; SINTERING; SURFACE STRUCTURE;

EID: 79960422749     PISSN: 02555476     EISSN: 16629752     Source Type: Book Series    
DOI: 10.4028/www.scientific.net/MSF.690.491     Document Type: Conference Paper
Times cited : (11)

References (10)
  • 1
    • 79960391905 scopus 로고    scopus 로고
    • Wiley-VCH, Weinheim, Germany
    • K. U. Kainer, Magnesium, Wiley-VCH, Weinheim, Germany, (2010).
    • (2010) Magnesium
    • Kainer, K.U.1
  • 2
    • 28844481103 scopus 로고    scopus 로고
    • Magnesium and its alloys as orthopedic biomaterials: A review
    • DOI 10.1016/j.biomaterials.2005.10.003, PII S0142961205009014
    • M. P. Staiger, A. M. Pietak, J. Huadmai, G. Dias, Magnesium and its alloys as orthopedic biomaterials: A review, Biomaterials Vol. 27 (2006), p. 1728-1734. (Pubitemid 41760433)
    • (2006) Biomaterials , vol.27 , Issue.9 , pp. 1728-1734
    • Staiger, M.P.1    Pietak, A.M.2    Huadmai, J.3    Dias, G.4
  • 3
    • 34249010154 scopus 로고    scopus 로고
    • Biodegradable magnesium scaffolds: Part I: Appropriate inflammatory response
    • DOI 10.1002/jbm.a.31170
    • F. Witte, H. Ulrich, M. Rudert, E. Willbold, Biodegradable magnesium scaffolds: Part I: Appropriate inflammatory response, Journal of Biomedical Materials Research Vol. 81A (2007), p. 748-756. (Pubitemid 46786907)
    • (2007) Journal of Biomedical Materials Research - Part A , vol.81 , Issue.3 , pp. 748-756
    • Witte, F.1    Ulrich, H.2    Rudert, M.3    Willbold, E.4
  • 4
    • 27644597192 scopus 로고    scopus 로고
    • In vitro and in vivo corrosion measurements of magnesium alloys
    • DOI 10.1016/j.biomaterials.2005.07.037, PII S0142961205007088
    • F. Witte, J. Fischer, J. Nellesen, H. A. Crostack, V.Kraese, A. Pisch, F. Beckmann, H. Windhagen, In vitro and in vivo corrosion measurements of magnesium alloys, Biomaterials Vol. 27 (2006), p. 1013-1018. (Pubitemid 41566693)
    • (2006) Biomaterials , vol.27 , Issue.7 , pp. 1013-1018
    • Witte, F.1    Fischer, J.2    Nellesen, J.3    Crostack, H.-A.4    Kaese, V.5    Pisch, A.6    Beckmann, F.7    Windhagen, H.8
  • 5
    • 34249086513 scopus 로고    scopus 로고
    • Biodegradable magnesium scaffolds: Part II: Peri-implant bone remodeling
    • DOI 10.1002/jbm.a.31293
    • F. Witte, H. Ulrich, C. Palm, E. Willbold, Biodegradable magnesium scaffolds: Part II: Periimplant bone remodelling, Journal of Biomedical Materials Research Vol. 81A (2007), p. 757-765 (Pubitemid 46786908)
    • (2007) Journal of Biomedical Materials Research - Part A , vol.81 , Issue.3 , pp. 757-765
    • Witte, F.1    Ulrich, H.2    Palm, C.3    Willbold, E.4
  • 6
    • 0027577495 scopus 로고
    • Comparison of mechanical properties of human, bovine bone and a newprocessed bone xenograft
    • G. Poumarat, P. Squire, Comparison of mechanical properties of human, bovine bone and a newprocessed bone xenograft, Biomaterials Vol. 14 (1993), p. 337-349.
    • (1993) Biomaterials , vol.14 , pp. 337-349
    • Poumarat, G.1    Squire, P.2
  • 7
    • 77954661736 scopus 로고    scopus 로고
    • Magnesium hydroxide temporarily enhancing osteoblast activity and decreasing the osteoclast number in peri-implant bone remodeling
    • C. Janning, E. Willbold, C. Vogt, J. Nellesen, A. Meyer-Lindenberg, H. Windbergen, F. Thorey, F. Witte, Magnesium hydroxide temporarily enhancing osteoblast activity and decreasing the osteoclast number in peri-implant bone remodelling, Acta Biomaterialica Vol. 6 (2010), p. 1861-68.
    • (2010) Acta Biomaterialica , vol.6 , pp. 1861-1868
    • Janning, C.1    Willbold, E.2    Vogt, C.3    Nellesen, J.4    Meyer-Lindenberg, A.5    Windbergen, H.6    Thorey, F.7    Witte, F.8
  • 8
    • 84902154144 scopus 로고    scopus 로고
    • Sintering of Mg and Mg-Ca alloys for biomedical applications
    • M. Wolff, T. Guelck, T. Ebel, Sintering of Mg and Mg-Ca alloys for biomedical applications, Euro PM2009 Proceed. Vol. 2, p. 417-422.
    • Euro PM2009 Proceed. , vol.2 , pp. 417-422
    • Wolff, M.1    Guelck, T.2    Ebel, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.