메뉴 건너뛰기




Volumn 39, Issue 10, 2011, Pages 965-978

Evaluating condition index and its probability distribution using monitored data of circuit breaker

Author keywords

circuit breaker; condition monitoring; condition based maintenance; kernel density evaluation; monitored data

Indexed keywords

CIRCUIT BREAKER; CONDITION BASED MAINTENANCE; CONDITION INDEX; KERNEL DENSITY; MONITORED DATA; MONITORED PARAMETERS; NORMAL CONDITION; NORMALIZED PARAMETERS; POWER EQUIPMENT; PROBABILITY DENSITY DISTRIBUTION;

EID: 79960343563     PISSN: 15325008     EISSN: 15325016     Source Type: Journal    
DOI: 10.1080/15325008.2011.552091     Document Type: Article
Times cited : (22)

References (18)
  • 1
    • 85008041954 scopus 로고    scopus 로고
    • Risk-based planner for asset management
    • October
    • Anders, G. J., Endrenyi, J., and Yung, C., "Risk-based planner for asset management," IEEE Comput. Appl. Power, Vol. 14, No. 4, pp. 20-26, October 2001.
    • (2001) IEEE Comput. Appl. Power , vol.14 , Issue.4 , pp. 20-26
    • Anders, G.J.1    Endrenyi, J.2    Yung, C.3
  • 2
    • 13844313055 scopus 로고    scopus 로고
    • A reliability-centered asset maintenance method for assessing the impact of maintenance in power distribution systems
    • DOI 10.1109/TPWRS.2004.840433
    • Bertling, L., Allan, R., and Eriksson, R., "A reliability-centered asset maintenance method for assessing the impact of maintenance in power distribution systems," IEEE Trans. Power Syst., Vol. 20, No. 1, pp. 75-82, February 2005. (Pubitemid 40259422)
    • (2005) IEEE Transactions on Power Systems , vol.20 , Issue.1 , pp. 75-82
    • Bertling, L.1    Allan, R.2    Eriksson, R.3
  • 3
    • 0346076729 scopus 로고    scopus 로고
    • A reliability-based approach to transmission maintenance planning and its application in BC hydro system
    • January
    • Li, W., and Korczynski, J., "A reliability-based approach to transmission maintenance planning and its application in BC hydro system," IEEE Trans. Power Delivery, Vol. 19, No. 1, pp. 303-308, January 2004.
    • (2004) IEEE Trans. Power Delivery , vol.19 , Issue.1 , pp. 303-308
    • Li, W.1    Korczynski, J.2
  • 6
    • 34147152235 scopus 로고    scopus 로고
    • Providing decision support for the condition-based maintenance of circuit breakers through data mining of trip coil current signatures
    • January
    • Scott, M. S., Stephen, D. J. M., Bruce, S., James, R. M., and Angus, C., "Providing decision support for the condition-based maintenance of circuit breakers through data mining of trip coil current signatures," IEEE Trans. Power Delivery, Vol. 22, No. 1, pp. 178-186, January 2007.
    • (2007) IEEE Trans. Power Delivery , vol.22 , Issue.1 , pp. 178-186
    • Scott, M.S.1    Stephen, D.J.M.2    Bruce, S.3    James, R.M.4    Angus, C.5
  • 7
    • 77955702713 scopus 로고    scopus 로고
    • An approach for condition-based maintenance optimization applied to wind turbine blades
    • July
    • Besnard, F., and Bertling, L., "An approach for condition-based maintenance optimization applied to wind turbine blades," IEEE Trans. Sustain. Energy, Vol. 1, No. 2, pp. 77-83, July 2010.
    • (2010) IEEE Trans. Sustain. Energy , vol.1 , Issue.2 , pp. 77-83
    • Besnard, F.1    Bertling, L.2
  • 8
    • 77953095960 scopus 로고    scopus 로고
    • Parameter estimation methods for condition-based maintenance with indirect observations
    • June
    • Ghasemi, A., Yacout, S., and Ouali, M. S., "Parameter estimation methods for condition-based maintenance with indirect observations," IEEE Trans. Reliability, Vol. 59, No. 2, pp. 426-439, June 2010.
    • (2010) IEEE Trans. Reliability , vol.59 , Issue.2 , pp. 426-439
    • Ghasemi, A.1    Yacout, S.2    Ouali, M.S.3
  • 9
    • 13244298423 scopus 로고    scopus 로고
    • Advanced sensor and diagnostic technologies for development of intelligent substations
    • 2004 IEEE Power Engineering Society General Meeting
    • Shoureshi, R., Norick, T., Permana, V., and Work, J., "Advanced sensor and diagnostic technologies for development of intelligent substations," Proceedings of IEEE Power Engineering Society General Meeting, pp. 727-746, Denver, CO, 6-10 June 2004. (Pubitemid 40192077)
    • (2004) 2004 IEEE Power Engineering Society General Meeting , vol.1 , pp. 727-746
    • Shoureshi, R.1    Norick, T.2    Permana, V.3    Work, J.4
  • 10
    • 38549159414 scopus 로고    scopus 로고
    • Electrical contacts condition diagnostics based on wireless temperature monitoring of energized equipment
    • DOI 10.1109/HOLM.2006.284068, 4063104, Electrical Contacts 2006: Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts
    • Chudnovsky, B. H., "Electrical contacts condition diagnostics based on wireless temperature monitoring of energized equipment," Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts, pp. 73-80, Montreal, 25-27 September 2006. (Pubitemid 351145148)
    • (2007) Electrical Contacts, Proceedings of the Annual Holm Conference on Electrical Contacts , pp. 73-80
    • Chudnovsky, B.H.1
  • 11
    • 7244232682 scopus 로고    scopus 로고
    • An evidential reasoning approach to transformer condition assessments
    • October
    • Tang,W. H., Spurgeon,K.,Wu, Q. H., and Richardson, Z. J., "An evidential reasoning approach to transformer condition assessments," IEEE Trans. Power Delivery, Vol. 19, No. 4, pp. 1696-1703, October 2004.
    • (2004) IEEE Trans. Power Delivery , vol.19 , Issue.4 , pp. 1696-1703
    • Tang, W.H.1    Spurgeon, K.2    Wu, Q.H.3    Richardson, Z.J.4
  • 16
    • 50849085133 scopus 로고    scopus 로고
    • Model for quantifying the effect of circuit breaker maintenance using condition-based data
    • Lausanne, Switzerland -5 July
    • Natti, S., and Kezunovic, M., "Model for quantifying the effect of circuit breaker maintenance using condition-based data," IEEE PES PowerTech Conference, pp. 1605-1610, Lausanne, Switzerland, 1-5 July 2007.
    • (2007) IEEE PES PowerTech Conference , pp. 1605-1610
    • Natti, S.1    Kezunovic, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.