메뉴 건너뛰기




Volumn , Issue , 2010, Pages 3073-3078

A hybrid between region-based and voxel-based methods for Partial Volume correction in PET

Author keywords

[No Author keywords available]

Indexed keywords

BRAIN AREAS; BRAIN PHANTOMS; DECONVOLUTION APPROACH; HETEROGENEOUS STRUCTURES; HOMOGENOUS REGION; ILL-CONDITIONED; IMAGE VOLUME; IMAGE-BASED; ITERATIVE DECONVOLUTION ALGORITHMS; LIMITED RESOLUTION; LOSS-OF-SIGNAL; MEASURED DATA; PARTIAL VOLUME CORRECTION; PARTIAL VOLUMES; PET IMAGING; REGION-BASED; REGION-BASED METHODS;

EID: 79960339356     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2010.5874365     Document Type: Conference Paper
Times cited : (9)

References (9)
  • 1
    • 0018367149 scopus 로고
    • Quantitation in positron emission computed tomography: 1. Effect of object size
    • Hoffman E J, Huang S C and Phelps M E 1979 "Quantitation in positron emission computed tomography: 1. Effect of object size" in J. Comput. Assist. Tomogr. 3 299-308
    • (1979) J. Comput. Assist. Tomogr. , vol.3 , pp. 299-308
    • Hoffman, E.J.1    Huang, S.C.2    Phelps, M.E.3
  • 2
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp L A and Vardi Y 1982 "Maximum likelihood reconstruction for emission tomography" IEEE Trans. Med.Imaging 1 113-22
    • (1982) IEEE Trans. Med.Imaging , vol.1 , pp. 113-22
    • Shepp, L.A.1    Vardi, Y.2
  • 3
    • 0031955835 scopus 로고    scopus 로고
    • Correction for partial volume effects in PET: Principle and validation
    • Rousset O G, Ma Y and Evans A C 1998 "Correction for partial volume effects in PET: principle and validation" J.Nucl. Med. 39 904-11
    • (1998) J.Nucl. Med. , vol.39 , pp. 904-11
    • Rousset, O.G.1    Ma, Y.2    Evans, A.C.3
  • 4
    • 0001050714 scopus 로고
    • An iterative technique for the rectification of observed distributions
    • Lucy L B 1974 "An iterative technique for the rectification of observed distributions." Astronomical Journal. 79 745.
    • (1974) Astronomical Journal. , vol.79 , pp. 745
    • Lucy, L.B.1
  • 5
    • 0002594849 scopus 로고
    • Bayesian-based iterative method of image restoration
    • Richardson W H 1972. "Bayesian-Based Iterative Method of Image Restoration." J. Opt. Soc. Am. 62(1) 55-59.
    • (1972) J. Opt. Soc. Am. , vol.62 , Issue.1 , pp. 55-59
    • Richardson, W.H.1
  • 6
    • 0029792211 scopus 로고    scopus 로고
    • Positron emission tomography metabolic data corrected for cortical atrophy using magnetic resonance imaging
    • Labbé C 1996 "Positron emission tomography metabolic data corrected for cortical atrophy using magnetic resonance imaging". Alzheimer Dis Assoc Disord, 10(3) 141-70.
    • (1996) Alzheimer Dis Assoc Disord , vol.10 , Issue.3 , pp. 141-170
    • Labbé, C.1
  • 7
    • 1542504654 scopus 로고    scopus 로고
    • Integrated software for the analysis of brain PET/SPECT studies with partial-volume-effect correction
    • Quarantelli, M., et al., 2004 "Integrated Software for the Analysis of Brain PET/SPECT Studies with Partial-Volume-Effect Correction". J Nucl Med 45(2) 192-201.
    • (2004) J Nucl Med , vol.45 , Issue.2 , pp. 192-201
    • Quarantelli, M.1
  • 9
    • 0041569918 scopus 로고    scopus 로고
    • Three-Dimensional maximum probability atlas of the human brain, with particular reference to the temporal lobe
    • Hammers A, Allom R, et al. 2003 "Three-Dimensional maximum probability atlas of the human brain, with particular reference to the temporal lobe" Hum Brain Mapp. 19 224-247.
    • (2003) Hum Brain Mapp. , vol.19 , pp. 224-247
    • Hammers, A.1    Allom, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.