메뉴 건너뛰기




Volumn , Issue , 2010, Pages 2826-2830

System design and development of a lower-cost animal PET-CT (MuPET) with large axial solid PET ring of 1.25-mm LYSO detectors

Author keywords

[No Author keywords available]

Indexed keywords

ANIMALS; COST ENGINEERING; DECODING; ELECTRONIC COOLING; IMAGE RESOLUTION; MEDICAL IMAGING; OPTICAL FIBERS; PELTIER EFFECT; SYSTEMS ANALYSIS; X RAY DETECTORS;

EID: 79960327434     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2010.5874310     Document Type: Conference Paper
Times cited : (2)

References (10)
  • 1
    • 0027644358 scopus 로고
    • A positron camera detector design with cross-coupled scintillators and quadrant sharing photomultipliers
    • Aug.
    • W-H. Wong, "A positron camera detector design with cross-coupled scintillators and quadrant sharing photomultipliers," IEEE Trans. Nucl. Sci., vol 40, no. 4, pp. 962-996, Aug. 1993.
    • (1993) IEEE Trans. Nucl. Sci. , vol.40 , Issue.4 , pp. 962-996
    • Wong, W.-H.1
  • 2
    • 10744226730 scopus 로고    scopus 로고
    • An efficient detector production method for position-sensitive scintillation detector arrays with 98% detector packing fraction
    • Oct.
    • J. Uribe, W-H. Wong, H. Li, H. Baghaei, Y. Wang, Y. Liu, et al., "An efficient detector production method for position-sensitive scintillation detector arrays with 98% detector packing fraction," IEEE Trans. Nucl. Sci., vol. 50, no. 5, pp.1469-1476, Oct. 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.5 , pp. 1469-1476
    • Uribe, J.1    Wong, W.-H.2    Li, H.3    Baghaei, H.4    Wang, Y.5    Liu, Y.6
  • 3
    • 45849088867 scopus 로고    scopus 로고
    • Highresolution L(Y)SO detector using PMT-Quadrant-Sharing for human and animal PET Cameras
    • Jun.
    • R. Ramirez, S. Liu, J. Liu, Y. Zhang, S. Kim, H. Baghaei, et al., "Highresolution L(Y)SO detector using PMT-Quadrant-Sharing for human and animal PET Cameras," IEEE Trans. Nucl. Sci., vol. 55, no. 3, 862-869, Jun. 2008.
    • (2008) IEEE Trans. Nucl. Sci. , vol.55 , Issue.3 , pp. 862-869
    • Ramirez, R.1    Liu, S.2    Liu, J.3    Zhang, Y.4    Kim, S.5    Baghaei, H.6
  • 4
    • 0036816137 scopus 로고    scopus 로고
    • A new pileup-prevention frond-end electronic design for high-resolution PET and gamma cameras
    • Oct.
    • H. Li, W-H. Wong, J. Uribe, H. Baghaei, Y. Liu, Y. Wang, et al., "A new pileup-prevention frond-end electronic design for high-resolution PET and gamma cameras," IEEE Trans. Nucl. Sci., vol. 49, no. 5, pp.2051-2056, Oct. 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , Issue.5 , pp. 2051-2056
    • Li, H.1    Wong, W.-H.2    Uribe, J.3    Baghaei, H.4    Liu, Y.5    Wang, Y.6
  • 5
    • 77951195164 scopus 로고    scopus 로고
    • A new statistics-based online baseline restorer for a high count-rate fully digital system
    • Apr.
    • H. Li, C. Wang, H. Baghaei, Y. Zhang, R. Ramirez, S. Liu, et al., "A new statistics-based online baseline restorer for a high count-rate fully digital system", IEEE Trans. Nucl. Sci., vol. 57, no. 2, pp. 550-555, Apr. 2010.
    • (2010) IEEE Trans. Nucl. Sci. , vol.57 , Issue.2 , pp. 550-555
    • Li, H.1    Wang, C.2    Baghaei, H.3    Zhang, Y.4    Ramirez, R.5    Liu, S.6
  • 6
    • 77951173100 scopus 로고    scopus 로고
    • A real time coincidence system for high count-rate TOF or Non-TOF PET cameras using hybrid method combining AND-logic and time-mark technology
    • Apr.
    • C. Wang, H. Li, Y. Zhang, H. Baghaei, R. Ramirez, S. Liu, et al., "A real time coincidence system for high count-rate TOF or Non-TOF PET cameras using hybrid method combining AND-logic and time-mark technology," IEEE Trans. Nucl. Sci., vol. 57, no. 2, pp. 708-714, Apr. 2010.
    • (2010) IEEE Trans. Nucl. Sci. , vol.57 , Issue.2 , pp. 708-714
    • Wang, C.1    Li, H.2    Zhang, Y.3    Baghaei, H.4    Ramirez, R.5    Liu, S.6
  • 7
    • 29144491488 scopus 로고    scopus 로고
    • An instantaneous photomultiplier tube gain-tuning method for PET or gamma camera detectors using an LED network
    • Oct.
    • H. Li, Y. Liu, T. Xing, Y. Wang, J. Uribe, H. Baghaei, et al., "An instantaneous photomultiplier tube gain-tuning method for PET or gamma camera detectors using an LED network", IEEE Trans. Nucl. Sci., vol. 52, no. 1, pp. 1295-1299, Oct. 2005.
    • (2005) IEEE Trans. Nucl. Sci. , vol.52 , Issue.1 , pp. 1295-1299
    • Li, H.1    Liu, Y.2    Xing, T.3    Wang, Y.4    Uribe, J.5    Baghaei, H.6
  • 8
    • 60449097895 scopus 로고    scopus 로고
    • Performance evaluation of the LabPEt12, a large axial FOV APD-based digital PET scanner
    • Feb.
    • M. Bergeron, J. Cadorette, C. Bureau-Oxton, J. Beaudoin, M. Tetrault, J. Leroux, et al., "Performance evaluation of the LabPEt12, a large axial FOV APD-based digital PET scanner", IEEE Trans. Nucl. Sci., vol. 56, no. 1, pp. 10-16, Feb. 2009.
    • (2009) IEEE Trans. Nucl. Sci. , vol.56 , Issue.1 , pp. 10-16
    • Bergeron, M.1    Cadorette, J.2    Bureau-Oxton, C.3    Beaudoin, J.4    Tetrault, M.5    Leroux, J.6
  • 9
    • 0023640412 scopus 로고
    • Treatment of axial data in three-dimensional PET
    • M. E. Daube-Witherspoon and G. Muehllehner, "Treatment of axial data in three-dimensional PET," J. Nucl. Med., vol. 28, pp. 1717-1724, 1987.
    • (1987) J. Nucl. Med. , vol.28 , pp. 1717-1724
    • Daube-Witherspoon, M.E.1    Muehllehner, G.2
  • 10
    • 58249119445 scopus 로고    scopus 로고
    • Spatial resolution and sensitivity of the Inveon smallanimal PET scanner
    • E. Visser, J. Disselhorst, M. Brom, P. Laverman, M. Gotthardt, W. Oyen, et al., "Spatial resolution and sensitivity of the Inveon smallanimal PET scanner", J. Nucl. Med., vol. 50, no. 1, pp. 139-147, 2009.
    • (2009) J. Nucl. Med. , vol.50 , Issue.1 , pp. 139-147
    • Visser, E.1    Disselhorst, J.2    Brom, M.3    Laverman, P.4    Gotthardt, M.5    Oyen, W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.