An instantaneous photomultiplier tube gain-tuning method for PET or gamma camera detectors using an LED network

Author keywords

Calibration; Light emitting diode (LED); Photo multiplier tube (PMT); Positron emission tomography (PET)

Indexed keywords

GAIN-TUNING METHOD; PATIENT LOAD; ROOM TEMPERATURE; SCINTILLATION CRYSTALS;

EID: 29144491488     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2005.858233     Document Type: Article
Times cited : (7)

References (7)
  • 2
    • 0032995626 scopus 로고    scopus 로고
    • Changes in the energy response of a dedicated gamma camera after exposure to a high-flux irradiation
    • R. Matheoud, F. Zito, C. Canz, F. Voltini, and P. Gerundini, "Changes in the energy response of a dedicated gamma camera after exposure to a high-flux irradiation," Phys. Med. Biol., vol. 44, pp. N129-N135, 1999.
    • (1999) Phys. Med. Biol. , vol.44
    • Matheoud, R.1    Zito, F.2    Canz, C.3    Voltini, F.4    Gerundini, P.5
  • 3
    • 0030170247 scopus 로고    scopus 로고
    • Design of a variable field prototype PET camera
    • Jun.
    • W.-H. Wong, J. Uribe, K. Hicks, G. Hu, and W. Lu, "Design of a variable field prototype PET camera," IEEE Trans. Nucl. Sci., vol. 43, pp. 1915-1920, Jun. 1996.
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , pp. 1915-1920
    • Wong, W.-H.1    Uribe, J.2    Hicks, K.3    Hu, G.4    Lu, W.5
  • 5
    • 29144476151 scopus 로고    scopus 로고
    • Calibration and stability of the high resolution fly's eye detector
    • Hamburg, Germany
    • B. F. Jones, J. N. Mathhews, S. A. Moore, and S. B. Thomas, "Calibration and stability of the high resolution fly's eye detector, " in 27th Int. Cosmic Ray Conf., Hamburg, Germany, 2001, pp. 641-644.
    • (2001) 27th Int. Cosmic Ray Conf. , pp. 641-644
    • Jones, B.F.1    Mathhews, J.N.2    Moore, S.A.3    Thomas, S.B.4
  • 6
    • 34648843314 scopus 로고    scopus 로고
    • Effect of the rotational orientation of circular photomultipliers in a PET camera block detector design
    • Jun.
    • J. Uribe, W.-H. Wong, G. Hu, K. Hicks, J. Wang, H. Baghaei, N. Zhang, H. Li, and S. Yokoyama, "Effect of the rotational orientation of circular photomultipliers in a PET camera block detector design," IEEE Trans. Nucl. Sci., vol. 44, no. 3, pp. 1266-1270, Jun. 1997.
    • (1997) IEEE Trans. Nucl. Sci. , vol.44 , Issue.3 , pp. 1266-1270
    • Uribe, J.1    Wong, W.-H.2    Hu, G.3    Hicks, K.4    Wang, J.5    Baghaei, H.6    Zhang, N.7    Li, H.8    Yokoyama, S.9
  • 7
    • 0036815732 scopus 로고    scopus 로고
    • An iterative energy-centroid method for recalibration of PMT gain in PET or gamma camera
    • Oct.
    • Y. Wang, W.-H. Wong, M. Aykac, J. Uribe, H. Li, H. Baghaei, Y. Liu, and T. Xing, "An iterative energy-centroid method for recalibration of PMT gain in PET or gamma camera," IEEE Trans. Nucl. Sci., vol. 49, no. 5, pp. 2047-2050, Oct. 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , Issue.5 , pp. 2047-2050
    • Wang, Y.1    Wong, W.-H.2    Aykac, M.3    Uribe, J.4    Li, H.5    Baghaei, H.6    Liu, Y.7    Xing, T.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.