-
3
-
-
0031192203
-
A steady-state high-temperature apparatus for measuring thermal conductivity of ceramics
-
B.J. Filla A steady-state high-temperature apparatus for measuring thermal conductivity of ceramics Rev. Sci. Instrum. 68 1997 2822 2829 (Pubitemid 127618529)
-
(1997)
Review of Scientific Instruments
, vol.68
, Issue.7
, pp. 2822-2829
-
-
Filla, B.J.1
-
5
-
-
0040208481
-
Atomization characteristics of lead determined in alumina matrices by slurry-electrothermal atomization atomic-absorption spectrometry
-
R. Karwowska, and K.W. Jackson Atomization characteristics of lead determined in alumina matrices by slurry-electrothermal atomization atomic-absorption spectrometry J. Anal. At. Spectrom. 2 1987 125 129
-
(1987)
J. Anal. At. Spectrom.
, vol.2
, pp. 125-129
-
-
Karwowska, R.1
Jackson, K.W.2
-
6
-
-
2042462602
-
Determination of gallium in aluminum-oxide by atomic absorption spectrometry with electrothermal atomization - Effect of gallium bond and aluminum-oxide modification on the analytical signal under slurry atomization conditions
-
J. Marecek, and V. Synek Determination of gallium in aluminum-oxide by atomic absorption spectrometry with electrothermal atomization - effect of gallium bond and aluminum-oxide modification on the analytical signal under slurry atomization conditions J. Anal. At. Spectrom. 5 1990 385 392
-
(1990)
J. Anal. At. Spectrom.
, vol.5
, pp. 385-392
-
-
Marecek, J.1
Synek, V.2
-
7
-
-
0001108198
-
Determination of trace amounts of heavy-metals in alumina by electrothermal atomic-absorption spectrometry after diethyldithiocarbamate extraction and matrix precipitation
-
M. Hiraide, T. Uchida, and H. Kawaguchi Determination of trace amounts of heavy-metals in alumina by electrothermal atomic-absorption spectrometry after diethyldithiocarbamate extraction and matrix precipitation Analyst 118 1993 537 539
-
(1993)
Analyst
, vol.118
, pp. 537-539
-
-
Hiraide, M.1
Uchida, T.2
Kawaguchi, H.3
-
8
-
-
0032071504
-
Slurry sampling electrothermal atomic absorption spectrometry for the analysis of aluminum-based ceramic powders
-
M. Lucic, and V. Krivan Slurry sampling electrothermal atomic absorption spectrometry for the analysis of aluminum-based ceramic powders Appl. Spectrosc. 52 1998 663 672 (Pubitemid 128618646)
-
(1998)
Applied Spectroscopy
, vol.52
, Issue.5
, pp. 663-672
-
-
Lucic, M.1
Krivan, V.2
-
9
-
-
0032178727
-
Solid sampling electrothermal atomic absorption spectrometry for analysis of aluminium oxide powders
-
M. Lucic, and V. Krivan Solid sampling electrothermal atomic absorption spectrometry for analysis of aluminium oxide powders J. Anal. At. Spectrom. 13 1998 1133 1139 (Pubitemid 128584803)
-
(1998)
Journal of Analytical Atomic Spectrometry
, vol.13
, Issue.10
, pp. 1133-1139
-
-
Lucie, M.1
Krivan, V.2
-
10
-
-
0034249443
-
Matrix removal by thermal fluorination in the graphite furnace atomic absorption analysis of high purity aluminum
-
S. Scaccia, and G. Zappa Matrix removal by thermal fluorination in the graphite furnace atomic absorption analysis of high purity aluminum Spectrochim. Acta B 55 2000 1271 1278
-
(2000)
Spectrochim. Acta B
, vol.55
, pp. 1271-1278
-
-
Scaccia, S.1
Zappa, G.2
-
11
-
-
0034884232
-
Direct determination of silicon in powdered aluminium oxide by use of slurry sampling with in situ fusion graphite-furnace atomic-absorption spectrometry
-
H. Minami, T. Yoshida, K. Okutsu, Q.B. Zhang, S. Inoue, and I. Atsuya Direct determination of silicon in powdered aluminium oxide by use of slurry sampling with in situ fusion graphite-furnace atomic-absorption spectrometry Fresenius J. Anal. Chem. 370 2001 855 859
-
(2001)
Fresenius J. Anal. Chem.
, vol.370
, pp. 855-859
-
-
Minami, H.1
Yoshida, T.2
Okutsu, K.3
Zhang, Q.B.4
Inoue, S.5
Atsuya, I.6
-
12
-
-
34548650576
-
Determination of cadmium, copper and lead in alumina based catalysts by direct solid sampling graphite furnace atomic absorption spectrometry
-
DOI 10.1016/j.sab.2007.04.011, PII S0584854707001309
-
L.F. Rodrigues, J.C.P. de Mattos, V.L. Dressler, D. Pozebon, and E.M.D. Flores Determination of cadmium, copper and lead in alumina based catalysts by direct solid sampling graphite furnace atomic absorption spectrometry Spectrochim. Acta B 62 2007 933 938 (Pubitemid 47405115)
-
(2007)
Spectrochimica Acta - Part B Atomic Spectroscopy
, vol.62
, Issue.9
, pp. 933-938
-
-
Rodrigues, L.F.1
Paz De Mattos, J.C.2
Dressler, V.L.3
Pozebon, D.4
De Moraes Flores, E.M.5
-
13
-
-
77951834482
-
Simultaneous determination of chromium and manganese in alumina by slurry sampling graphite furnace atomic absorption spectrometry using NbC and NaF as modifiers
-
A.L. Souza, and P.V. Oliveira Simultaneous determination of chromium and manganese in alumina by slurry sampling graphite furnace atomic absorption spectrometry using NbC and NaF as modifiers J. Anal. At. Spectrom. 25 2010 675 680
-
(2010)
J. Anal. At. Spectrom.
, vol.25
, pp. 675-680
-
-
Souza, A.L.1
Oliveira, P.V.2
-
14
-
-
0021202068
-
Determination of trace impurities in high-purity aluminum oxide by inductively-coupled plasma atomic emission spectrometry
-
T. Ishizuka Y, Uwamino, A. Tsuge, T. Kamiyanagi, Determination of trace impurities in high-purity aluminum-oxide by inductively-coupled plasma atomic emission-spectrometry Anal. Chim. Acta 161 1984 285 291 (Pubitemid 14008468)
-
(1984)
Analytica Chimica Acta
, vol.VOL. 161
, pp. 285-291
-
-
Ishizuka, T.1
Uwamino, Y.2
Tsuge, A.3
Kamiyanagi, T.4
-
15
-
-
84996031803
-
Determination of trace impurities in high-purity aluminum-oxide by acid pressure decomposition-ICP-AES
-
H. Morikawa, Y. Lida, T. Ishizuka, and F. Yokota Determination of trace impurities in high-purity aluminum-oxide by acid pressure decomposition-ICP-AES Bunseki Kagaku 35 1986 636 640
-
(1986)
Bunseki Kagaku
, vol.35
, pp. 636-640
-
-
Morikawa, H.1
Lida, Y.2
Ishizuka, T.3
Yokota, F.4
-
16
-
-
0004241824
-
Dissolution of alpha-alumina for elemental analysis by inductively coupled plasma atomic emission-spectrometry
-
E.H. Homeier, R.J. Kot, L.J. Bauer, and J.T. Genualdi Dissolution of alpha-alumina for elemental analysis by inductively coupled plasma atomic emission-spectrometry J. Anal. At. Spectrom. 3 1988 829 834
-
(1988)
J. Anal. At. Spectrom.
, vol.3
, pp. 829-834
-
-
Homeier, E.H.1
Kot, R.J.2
Bauer, L.J.3
Genualdi, J.T.4
-
17
-
-
0002394218
-
Microwave-assisted dissolution of aluminum-oxide samples
-
E. Tatar, I. Varga, and G. Zaray Microwave-assisted dissolution of aluminum-oxide samples Mikrochim. Acta 111 1993 45 54
-
(1993)
Mikrochim. Acta
, vol.111
, pp. 45-54
-
-
Tatar, E.1
Varga, I.2
Zaray, G.3
-
18
-
-
0006029679
-
Analysis of aluminium-based ceramic powders by electrothermal vaporization inductively coupled plasma atomic emission spectrometry using a tungsten coil and slurry sampling
-
M. Lucic, and V. Krivan Analysis of aluminium-based ceramic powders by electrothermal vaporization inductively coupled plasma atomic emission spectrometry using a tungsten coil and slurry sampling Fresenius J. Anal. Chem. 363 1999 64 72
-
(1999)
Fresenius J. Anal. Chem.
, vol.363
, pp. 64-72
-
-
Lucic, M.1
Krivan, V.2
-
19
-
-
0035124577
-
Slurry sampling fluorination assisted electrothermal vaporization- inductively coupled plasma-atomic emission spectrometry for the direct determination of metal impurities in aluminium oxide ceramic powders
-
T.Y. Peng, G. Chang, L. Wang, Z.C. Jiang, and B. Hu Slurry sampling fluorination assisted electrothermal vaporization-inductively coupled plasma-atomic emission spectrometry for the direct determination of metal impurities in aluminium oxide ceramic powders Fresenius J. Anal. Chem. 369 2001 461 465
-
(2001)
Fresenius J. Anal. Chem.
, vol.369
, pp. 461-465
-
-
Peng, T.Y.1
Chang, G.2
Wang, L.3
Jiang, Z.C.4
Hu, B.5
-
20
-
-
0032115993
-
Electrothermal vaporization-inductively coupled plasma mass spectrometry for determination of metal impurities in slurries of aluminium oxide
-
J. Mierzwa, and M.H. Yang Electrothermal vaporization inductively coupled plasma mass spectrometry for determination of metal impurities in slurries of aluminium oxide J. Anal. At. Spectrom. 13 1998 667 671 (Pubitemid 128559101)
-
(1998)
Journal of Analytical Atomic Spectrometry
, vol.13
, Issue.7
, pp. 667-671
-
-
Mierzwa, J.1
Yang, M.-H.2
-
21
-
-
32344450223
-
3 ceramic powders
-
DOI 10.1016/j.sab.2005.11.007, PII S0584854705003381
-
3 ceramic powders Spectrochim. Acta B 61 2006 42 49 (Pubitemid 43220324)
-
(2006)
Spectrochimica Acta - Part B Atomic Spectroscopy
, vol.61
, Issue.1
, pp. 42-49
-
-
Peschel, B.U.1
Andrade, F.2
Wetzel, W.C.3
Schilling, G.D.4
Hieftje, G.M.5
Broekaert, J.A.C.6
Sperline, R.7
Denton, M.B.8
Barinaga, C.J.9
Koppenaal, D.W.10
-
24
-
-
0001563233
-
Study of matrix effects on determination of trace elements in aluminum, using inductively coupled plasma atomic emission spectrometry, 1) selection of spectral lines
-
M. Saleem, K. Anwar, and D. Mohammad Study of matrix effects on determination of trace elements in aluminum, using inductively coupled plasma atomic emission spectrometry. 1. Selection of spectral lines Anal. Lett. 29 1996 1871 1881 (Pubitemid 126452308)
-
(1996)
Analytical Letters
, vol.29
, Issue.10
, pp. 1871-1881
-
-
Saleem, M.1
Anwar, K.2
Mohammad, D.3
-
26
-
-
0037349084
-
Selection of internal standards in inductively coupled plasma atomic emission spectrometry by principal component analysis
-
M. Grotti, E. Magi, and R. Leardi Selection of internal standards in inductively coupled plasma atomic emission spectrometry by principal component analysis J. Anal. At. Spectrom. 18 2003 274 281
-
(2003)
J. Anal. At. Spectrom.
, vol.18
, pp. 274-281
-
-
Grotti, M.1
Magi, E.2
Leardi, R.3
-
27
-
-
0002817932
-
ICP emission spectrometers - 1995 Analytical figures of merit
-
J.M. Mermet, and E. Poussel ICP emission spectrometers - 1995 Analytical figures of merit Appl. Spectrosc. 49 1995 A12 A18
-
(1995)
Appl. Spectrosc.
, vol.49
-
-
Mermet, J.M.1
Poussel, E.2
-
28
-
-
0000154593
-
Nomenclature, symbols, units and their usage in spectrochemical analysis II. Data interpretation
-
IUPAC Nomenclature, symbols, units and their usage in spectrochemical analysis II. Data interpretation Spectrochim. Acta B 33 1978 241 245
-
(1978)
Spectrochim. Acta B
, vol.33
, pp. 241-245
-
-
-
29
-
-
79953039243
-
Exploring the emission intensities of ICP OES aided by chemometrics in the geographical discrimination of mineral waters
-
10.1039/c0ja00071j
-
A.L. Souza, S.G. Lemos, J. Naozuka, P.R.M. Correia, and P.V. Oliveira Exploring the emission intensities of ICP OES aided by chemometrics in the geographical discrimination of mineral waters J. Anal. At. Spectrom. 2011 10.1039/c0ja00071j
-
(2011)
J. Anal. At. Spectrom.
-
-
Souza, A.L.1
Lemos, S.G.2
Naozuka, J.3
Correia, P.R.M.4
Oliveira, P.V.5
-
31
-
-
0035971294
-
Matrix-induced shift effects in axially viewed inductively coupled plasma atomic emission spectrometry
-
DOI 10.1016/S0584-8547(01)00171-9, PII S0584854701001719
-
M. Stepan, P. Musil, E. Poussel, and J.M. Mermet Matrix-induced shift effects in axially viewed inductively coupled plasma atomic emission spectrometry Spectrochim. Acta B 56 2001 443 453 (Pubitemid 32420818)
-
(2001)
Spectrochimica Acta - Part B Atomic Spectroscopy
, vol.56
, Issue.4
, pp. 443-453
-
-
Stepan, M.1
Musil, P.2
Poussel, E.3
Mermet, J.M.4
|