-
1
-
-
0031367311
-
Improved slurry sampling electrothermal vaporization system using a tungsten coil for inductively coupled plasma atomic emission spectrometry
-
P. Barth, S. Hauptkorn, and V. Krivan Improved slurry sampling electrothermal vaporization system using a tungsten coil for inductively coupled plasma atomic emission spectrometry J. Anal. At. Spectrom. 12 1997 1351 1358
-
(1997)
J. Anal. At. Spectrom.
, vol.12
, pp. 1351-1358
-
-
Barth, P.1
Hauptkorn, S.2
Krivan, V.3
-
2
-
-
8344240466
-
Molybdenum, platinum and tantalum metal atomizers or vaporizers in analytical atomic spectrometry
-
G. Zhong, H. Luo, Z. Zhou, and X. Hou Molybdenum, platinum and tantalum metal atomizers or vaporizers in analytical atomic spectrometry Appl. Spectrosc. Rev. 39 2004 475 507
-
(2004)
Appl. Spectrosc. Rev.
, vol.39
, pp. 475-507
-
-
Zhong, G.1
Luo, H.2
Zhou, Z.3
Hou, X.4
-
3
-
-
0020799440
-
Determination of trace metals in synthetic ocean water by inductively coupled plasma atomic emission spectrometry with electrothermal carbon cup vaporization
-
K.C. Ng, and J.A. Caruso Determination of trace metals in synthetic ocean water by inductively coupled plasma atomic emission spectrometry with electrothermal carbon cup vaporization Anal. Chem. 55 1983 1513 1516
-
(1983)
Anal. Chem.
, vol.55
, pp. 1513-1516
-
-
Ng, K.C.1
Caruso, J.A.2
-
4
-
-
34250075432
-
Electrothermal vaporization inductively coupled plasma atomic emission spectrometry for the analysis of solid samples: Contribution to instrumentation and methodology
-
P. Verrept, R. Dams, and U. Kurfürst Electrothermal vaporization inductively coupled plasma atomic emission spectrometry for the analysis of solid samples: contribution to instrumentation and methodology Fresenius' J. Anal. Chem. 346 1993 1035 1041
-
(1993)
Fresenius' J. Anal. Chem.
, vol.346
, pp. 1035-1041
-
-
Verrept, P.1
Dams, R.2
Kurfürst, U.3
-
5
-
-
0037010544
-
Direct solid sampling electrothermal vaporization of alumina for analysis by inductively coupled plasma optical emission spectrometry
-
M.C. Wende, and J.A.C. Broekaert Direct solid sampling electrothermal vaporization of alumina for analysis by inductively coupled plasma optical emission spectrometry Spectrochim. Acta Part B 57 2002 1897 1904
-
(2002)
Spectrochim. Acta Part B
, vol.57
, pp. 1897-1904
-
-
Wende, M.C.1
Broekaert, J.A.C.2
-
6
-
-
0002788303
-
The benefits of electrothermal vaporization for minimizing interferences in ICP-MS
-
S. Beres, R. Thomas, E. Denoyer, and P. Brückner The benefits of electrothermal vaporization for minimizing interferences in ICP-MS Spectroscopy 9 1994 20 26
-
(1994)
Spectroscopy
, vol.9
, pp. 20-26
-
-
Beres, S.1
Thomas, R.2
Denoyer, E.3
Brückner, P.4
-
7
-
-
0037311312
-
Electrothermal vaporization-inductively coupled plasma mass spectrometry (ETV-ICP-MS): A valuable tool for direct multielement determination in solid samples
-
A. Martín-Esteban, and B. Slowikowski Electrothermal vaporization-inductively coupled plasma mass spectrometry (ETV-ICP-MS): a valuable tool for direct multielement determination in solid samples Crit. Rev. Anal. Chem. 355 2003 43 55
-
(2003)
Crit. Rev. Anal. Chem.
, vol.355
, pp. 43-55
-
-
Martín-Esteban, A.1
Slowikowski, B.2
-
8
-
-
0030710725
-
Direct determination of arsenic in fresh and saline waters by electrothermal vaporization inductively coupled plasma mass spectrometry
-
D.C. Grégoire, and M. de Lourdes Ballinas Direct determination of arsenic in fresh and saline waters by electrothermal vaporization inductively coupled plasma mass spectrometry Spectrochim. Acta Part B 52 1997 75 82
-
(1997)
Spectrochim. Acta Part B
, vol.52
, pp. 75-82
-
-
Grégoire, D.C.1
De Lourdes Ballinas, M.2
-
9
-
-
0030371598
-
Parameter optimization of electrothermal vaporization inductively coupled plasma mass spectrometry for oligoelement determination in standard reference materials
-
N.G. Berryman, and T.U. Probst Parameter optimization of electrothermal vaporization inductively coupled plasma mass spectrometry for oligoelement determination in standard reference materials Fresenius' J. Anal. Chem. 355 1996 783 788
-
(1996)
Fresenius' J. Anal. Chem.
, vol.355
, pp. 783-788
-
-
Berryman, N.G.1
Probst, T.U.2
-
10
-
-
0035526832
-
Evaluation of the multi-element capabilities of electrothermal vaporization quadrupole-based ICP mass spectrometry
-
M. Resano, M. Verstraete, F. Vanhaecke, and L. Moens Evaluation of the multi-element capabilities of electrothermal vaporization quadrupole-based ICP mass spectrometry J. Anal. At. Spectrom. 16 2001 1018 1027
-
(2001)
J. Anal. At. Spectrom.
, vol.16
, pp. 1018-1027
-
-
Resano, M.1
Verstraete, M.2
Vanhaecke, F.3
Moens, L.4
-
11
-
-
0033118284
-
Preliminary investigation of electrothermal vaporization sample introduction for inductively coupled plasma time-of-flight mass spectrometry
-
P.P. Mahoney, S.J. Ray, G. Li, and G.M. Hieftje Preliminary investigation of electrothermal vaporization sample introduction for inductively coupled plasma time-of-flight mass spectrometry Anal. Chem. 71 1999 1378 1383
-
(1999)
Anal. Chem.
, vol.71
, pp. 1378-1383
-
-
Mahoney, P.P.1
Ray, S.J.2
Li, G.3
Hieftje, G.M.4
-
12
-
-
0037108802
-
Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph: 1. Use with a glow-discharge source
-
J.H. Barnes, R. Sperline, M.B. Denton, C.J. Barinaga, D. Koppenaal, E.T. Young, and G.M. Hieftje Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph: 1. Use with a glow-discharge source Anal. Chem. 74 2002 5327 5332
-
(2002)
Anal. Chem.
, vol.74
, pp. 5327-5332
-
-
Barnes, J.H.1
Sperline, R.2
Denton, M.B.3
Barinaga, C.J.4
Koppenaal, D.5
Young, E.T.6
Hieftje, G.M.7
-
13
-
-
2342454492
-
Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph: 2. Use with an inductively coupled plasma
-
J.H. Barnes, G.D. Schilling, R. Sperline, M.B. Denton, E.T. Young, C.J. Barinaga, D.W. Koppenaal, and G.M. Hieftje Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph: 2. Use with an inductively coupled plasma Anal. Chem. 76 2004 2531 2536
-
(2004)
Anal. Chem.
, vol.76
, pp. 2531-2536
-
-
Barnes, J.H.1
Schilling, G.D.2
Sperline, R.3
Denton, M.B.4
Young, E.T.5
Barinaga, C.J.6
Koppenaal, D.W.7
Hieftje, G.M.8
-
14
-
-
3042598292
-
Coupling of a gas chromatograph to a simultaneous-detection inductively coupled plasma mass spectrograph for speciation of organohalide and organometallic compounds
-
J.H. Barnes IV, G.D. Schilling, R.P. Sperline, M.B. Denton, E.T. Young, C.J. Barinaga, D.W. Koppenaal, and G.M. Hieftje Coupling of a gas chromatograph to a simultaneous-detection inductively coupled plasma mass spectrograph for speciation of organohalide and organometallic compounds J. Anal. At. Spectrom. 19 2004 751 756
-
(2004)
J. Anal. At. Spectrom.
, vol.19
, pp. 751-756
-
-
Barnes, J.H.I.V.1
Schilling, G.D.2
Sperline, R.P.3
Denton, M.B.4
Young, E.T.5
Barinaga, C.J.6
Koppenaal, D.W.7
Hieftje, G.M.8
-
15
-
-
0034249513
-
Electrothermal vaporization for sample introduction into a gas sampling glow discharge time-of-flight mass spectrometer
-
J.P. Guzowski Jr., J.A.C. Broekaert, and G.M. Hieftje Electrothermal vaporization for sample introduction into a gas sampling glow discharge time-of-flight mass spectrometer Spectrochim. Acta Part B 55 2000 1295 1314
-
(2000)
Spectrochim. Acta Part B
, vol.55
, pp. 1295-1314
-
-
Guzowski Jr., J.P.1
Broekaert, J.A.C.2
Hieftje, G.M.3
-
16
-
-
0031249373
-
Reducing the energy distribution in a plasma-source sector-field mass spectrometer interface
-
T.W. Burgoyne, G.M. Hieftje, and R.A. Hites Reducing the energy distribution in a plasma-source sector-field mass spectrometer interface J. Anal. At. Spectrom. 12 1997 1149 1153
-
(1997)
J. Anal. At. Spectrom.
, vol.12
, pp. 1149-1153
-
-
Burgoyne, T.W.1
Hieftje, G.M.2
Hites, R.A.3
-
18
-
-
0031060792
-
Space charge evaluation in a plasma-source mass spectrograph
-
T.W. Burgoyne, G.M. Hieftje, and R.A. Hites Space charge evaluation in a plasma-source mass spectrograph Anal. Chem. 69 1997 485 489
-
(1997)
Anal. Chem.
, vol.69
, pp. 485-489
-
-
Burgoyne, T.W.1
Hieftje, G.M.2
Hites, R.A.3
-
19
-
-
0030247135
-
Comparative analysis of aluminium oxide powders by inductively coupled plasma mass spectrometry with low and high mass resolution
-
N. Jakubowski, W. Tittes, D. Pollmann, D. Stuewer, and J.A.C. Broekaert Comparative analysis of aluminium oxide powders by inductively coupled plasma mass spectrometry with low and high mass resolution J. Anal. At. Spectrom. 11 1996 797 803
-
(1996)
J. Anal. At. Spectrom.
, vol.11
, pp. 797-803
-
-
Jakubowski, N.1
Tittes, W.2
Pollmann, D.3
Stuewer, D.4
Broekaert, J.A.C.5
-
20
-
-
0034918578
-
3 ceramic powders by slurry electothermal evaporation coupled with inductively-coupled plasma mass spectrometry (ETV-ICP-MS)
-
3 ceramic powders by slurry electothermal evaporation coupled with inductively-coupled plasma mass spectrometry (ETV-ICP-MS) Fresenius' J. Anal. Chem. 370 2001 513 520
-
(2001)
Fresenius' J. Anal. Chem.
, vol.370
, pp. 513-520
-
-
Wende, M.C.1
Broekaert, J.A.C.2
-
22
-
-
0028497915
-
Analysis of aluminium oxide and silicon carbide ceramic materials by inductively coupled plasma mass spectrometry
-
J.A.C. Broekaert, R. Brandt, F. Leis, C. Pilger, D. Pollmann, P. Tschöpel, and G. Tölg Analysis of aluminium oxide and silicon carbide ceramic materials by inductively coupled plasma mass spectrometry J. Anal. At. Spectrom. 9 1994 1063 1070
-
(1994)
J. Anal. At. Spectrom.
, vol.9
, pp. 1063-1070
-
-
Broekaert, J.A.C.1
Brandt, R.2
Leis, F.3
Pilger, C.4
Pollmann, D.5
Tschöpel, P.6
Tölg, G.7
-
23
-
-
0032071504
-
Slurry sampling electrothermal atomic absorption spectrometry for the analysis of aluminum-based ceramic powders
-
M. Lucic, and V. Krivan Slurry sampling electrothermal atomic absorption spectrometry for the analysis of aluminum-based ceramic powders Appl. Spectrosc. 52 1998 663 672
-
(1998)
Appl. Spectrosc.
, vol.52
, pp. 663-672
-
-
Lucic, M.1
Krivan, V.2
-
24
-
-
0006029679
-
Analysis of aluminium-based ceramic powders by electrothermal vaporization inductively coupled plasma atomic emission spectrometry using a tungsten coil and slurry sampling
-
M. Lucic, and V. Krivan Analysis of aluminium-based ceramic powders by electrothermal vaporization inductively coupled plasma atomic emission spectrometry using a tungsten coil and slurry sampling Fresenius' J. Anal. Chem. 363 1999 64 72
-
(1999)
Fresenius' J. Anal. Chem.
, vol.363
, pp. 64-72
-
-
Lucic, M.1
Krivan, V.2
-
25
-
-
0013254486
-
The use of plasma atomic spectrometric methods for the analysis of ceramic powders
-
J.A.C. Broekaert, C. Lathen, R. Brandt, C. Pilger, D. Pollmann, P. Tschöpel, and G. Tölg The use of plasma atomic spectrometric methods for the analysis of ceramic powders Fresenius' J. Anal. Chem. 349 1994 20 25
-
(1994)
Fresenius' J. Anal. Chem.
, vol.349
, pp. 20-25
-
-
Broekaert, J.A.C.1
Lathen, C.2
Brandt, R.3
Pilger, C.4
Pollmann, D.5
Tschöpel, P.6
Tölg, G.7
-
26
-
-
0027378419
-
Multi-element analysis of aluminum-based ceramic powders by instrumental and radiochemical neutron activation analysis
-
M. Franek, and V. Krivan Multi-element analysis of aluminum-based ceramic powders by instrumental and radiochemical neutron activation analysis Anal. Chim. Acta 282 1993 199 207
-
(1993)
Anal. Chim. Acta
, vol.282
, pp. 199-207
-
-
Franek, M.1
Krivan, V.2
-
27
-
-
0032178727
-
Solid sampling electrothermal atomic absorption spectrometry for analysis of aluminium oxide powders
-
M. Lucic, and V. Krivan Solid sampling electrothermal atomic absorption spectrometry for analysis of aluminium oxide powders J. Anal. At. Spectrom. 13 1998 1133 1139
-
(1998)
J. Anal. At. Spectrom.
, vol.13
, pp. 1133-1139
-
-
Lucic, M.1
Krivan, V.2
|