Volumn 35, Issue 7, 2011, Pages 682-690

Exercise capacity in patients supported with rotary blood pumps is improved by a spontaneous increase of pump flow at constant pump speed and by a rise in native cardiac output

Author keywords

Cardiac output; Exercise capability; Heart failure; Pump flow; Pump speed; Rotary blood pump

Indexed keywords

ARTIFICIAL HEART; BLOOD; BLOOD PRESSURE; CARDIOVASCULAR SURGERY; HEART; HEMODYNAMICS; LEFT VENTRICULAR ASSIST DEVICES; PUMPS; VANADIUM DIOXIDE;

EID: 79960204110     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2011.01227.x     Document Type: Article
Times cited : (46)

References (29)
  • 1
    • 0024592056 scopus 로고
    • Implantable electrical left ventricular assist system: bridge to transplantation and the future
    • Portner PM, Oyer PE, Pennington DG, etal. Implantable electrical left ventricular assist system: bridge to transplantation and the future. Ann Thorac Surg 1989;47:142-50.
    • (1989) Ann Thorac Surg , vol.47 , pp. 142-150
    • Portner, P.M.1    Oyer, P.E.2    Pennington, D.G.3
  • 2
    • 0034060818 scopus 로고    scopus 로고
    • Single-center experience with the Thoratec ventricular assist device
    • Körfer R, El-Banayosy A, Arusoglu L, etal. Single-center experience with the Thoratec ventricular assist device. J Thorac Cardiovasc Surg 2000;119:596-600.
    • (2000) J Thorac Cardiovasc Surg , vol.119 , pp. 596-600
    • Körfer, R.1    El-Banayosy, A.2    Arusoglu, L.3
  • 3
    • 0035892018 scopus 로고    scopus 로고
    • Long-term mechanical left ventricular assistance for end-stage heart failure
    • Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Study Group.
    • Rose EA, Gelijns AC, Moskowitz AJ, etal. Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Study Group. Long-term mechanical left ventricular assistance for end-stage heart failure. N Engl J Med 2001;345:1435-43.
    • (2001) N Engl J Med , vol.345 , pp. 1435-1443
    • Rose, E.A.1    Gelijns, A.C.2    Moskowitz, A.J.3
  • 4
    • 34548297997 scopus 로고    scopus 로고
    • Outcomes of left ventricular assist device implantation as destination therapy in the post-REMATCH era: implications for patient selection
    • Lietz K, Long JW, Kfoury AG, etal. Outcomes of left ventricular assist device implantation as destination therapy in the post-REMATCH era: implications for patient selection. Circulation 2007;116:497-505.
    • (2007) Circulation , vol.116 , pp. 497-505
    • Lietz, K.1    Long, J.W.2    Kfoury, A.G.3
  • 5
    • 34548311569 scopus 로고    scopus 로고
    • Use of a continuous-flow device in patients awaiting heart transplantation
    • HeartMate II Clinical Investigators.
    • Miller LW, Pagani FD, Russell SD, etal. HeartMate II Clinical Investigators. Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med 2007;357:885-96.
    • (2007) N Engl J Med , vol.357 , pp. 885-896
    • Miller, L.W.1    Pagani, F.D.2    Russell, S.D.3
  • 6
    • 73349129701 scopus 로고    scopus 로고
    • Advanced heart failure treated with continuous-flow left ventricular assist device
    • Slaughter MS, Rogers JG, Milano CA, etal. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 2009;361:2241-51.
    • (2009) N Engl J Med , vol.361 , pp. 2241-2251
    • Slaughter, M.S.1    Rogers, J.G.2    Milano, C.A.3
  • 7
    • 0343660199 scopus 로고    scopus 로고
    • Assessment of submaximal exercise capacity in patients with left ventricular assist devices
    • Foray A, Williams D, Reemtsma K, Oz M, Mancini D. Assessment of submaximal exercise capacity in patients with left ventricular assist devices. Circulation 1996;94(Suppl):II222-6.
    • (1996) Circulation , vol.94 , Issue.SUPPL
    • Foray, A.1    Williams, D.2    Reemtsma, K.3    Oz, M.4    Mancini, D.5
  • 8
    • 0030972176 scopus 로고    scopus 로고
    • Effects of exercise during long-term support with a left ventricular assist device. Results of the experience with left ventricular assist device with exercise (EVADE) pilot trial
    • Jaski BE, Kim J, Maly RS, etal. Effects of exercise during long-term support with a left ventricular assist device. Results of the experience with left ventricular assist device with exercise (EVADE) pilot trial. Circulation 1997;95:2401-6.
    • (1997) Circulation , vol.95 , pp. 2401-2406
    • Jaski, B.E.1    Kim, J.2    Maly, R.S.3
  • 9
    • 0032558413 scopus 로고    scopus 로고
    • Comparison of exercise performance in patients with chronic severe heart failure versus left ventricular assist devices
    • Mancini D, Goldsmith R, Levin H, etal. Comparison of exercise performance in patients with chronic severe heart failure versus left ventricular assist devices. Circulation 1998;98:1178-83.
    • (1998) Circulation , vol.98 , pp. 1178-1183
    • Mancini, D.1    Goldsmith, R.2    Levin, H.3
  • 10
    • 0032584113 scopus 로고    scopus 로고
    • Effects of exercise during long-term support with a left ventricular assist device
    • Deng MC, Wilhelm MJ, Scheld HH. Effects of exercise during long-term support with a left ventricular assist device. Circulation 1998;97:1212-3.
    • (1998) Circulation , vol.97 , pp. 1212-1213
    • Deng, M.C.1    Wilhelm, M.J.2    Scheld, H.H.3
  • 11
    • 0032721355 scopus 로고    scopus 로고
    • Comparison of functional capacity in patients with end-stage heart failure following implantation of a left ventricular assist device versus heart transplantation: results of the experience with left ventricular assist device with exercise trial
    • Jaski BE, Lingle RJ, Kim J, etal. Comparison of functional capacity in patients with end-stage heart failure following implantation of a left ventricular assist device versus heart transplantation: results of the experience with left ventricular assist device with exercise trial. J Heart Lung Transplant 1999;18:1031-40.
    • (1999) J Heart Lung Transplant , vol.18 , pp. 1031-1040
    • Jaski, B.E.1    Lingle, R.J.2    Kim, J.3
  • 12
    • 0035369058 scopus 로고    scopus 로고
    • Exercise performance in patients with end-stage heart failure after implantation of a left ventricular assist device and after heart transplantation: an outlook for permanent assisting?
    • de Jonge N, Kirkels H, Lahpor JR, etal. Exercise performance in patients with end-stage heart failure after implantation of a left ventricular assist device and after heart transplantation: an outlook for permanent assisting? J Am Coll Cardiol 2001;37:1794-9.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1794-1799
    • de Jonge, N.1    Kirkels, H.2    Lahpor, J.R.3
  • 13
    • 77950897411 scopus 로고    scopus 로고
    • HeartMate II Investigators. Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients
    • Rogers JG, Aaronson KD, Boyle AJ, etal. HeartMate II Investigators. Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients. J Am Coll Cardiol 2010;55:1826-34.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1826-1834
    • Rogers, J.G.1    Aaronson, K.D.2    Boyle, A.J.3
  • 14
    • 77349084865 scopus 로고    scopus 로고
    • Quality of life and functional status in patients surviving 12 months after left ventricular assist device implantation
    • Allen JG, Weiss ES, Schaffer JM, etal. Quality of life and functional status in patients surviving 12 months after left ventricular assist device implantation. J Heart Lung Transplant 2010;29:278-85.
    • (2010) J Heart Lung Transplant , vol.29 , pp. 278-285
    • Allen, J.G.1    Weiss, E.S.2    Schaffer, J.M.3
  • 15
    • 67650093608 scopus 로고    scopus 로고
    • Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device
    • Pagani FD, Miller LW, Russell SD, etal. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol 2009;54:312-21.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 312-321
    • Pagani, F.D.1    Miller, L.W.2    Russell, S.D.3
  • 16
    • 34748926436 scopus 로고    scopus 로고
    • Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices
    • Haft J, Armstrong W, Dyke DB, etal. Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices. Circulation 2007;116(Suppl):I8-15.
    • (2007) Circulation , vol.116 , Issue.SUPPL.
    • Haft, J.1    Armstrong, W.2    Dyke, D.B.3
  • 17
    • 0142151028 scopus 로고    scopus 로고
    • Acute cardiovascular response to exercise and its implications for exercise testing
    • Navare SM, Thompson PD. Acute cardiovascular response to exercise and its implications for exercise testing. J Nucl Cardiol 2003;10:521-8.
    • (2003) J Nucl Cardiol , vol.10 , pp. 521-528
    • Navare, S.M.1    Thompson, P.D.2
  • 18
    • 0021368736 scopus 로고
    • Predicted values for clinical exercise testing
    • Hansen JE, Sue DY, Wasserman K. Predicted values for clinical exercise testing. Am Rev Respir Dis 1984;129(Pt 2):S49-55.
    • (1984) Am Rev Respir Dis , vol.129 , Issue.PART 2
    • Hansen, J.E.1    Sue, D.Y.2    Wasserman, K.3
  • 19
    • 0032838992 scopus 로고    scopus 로고
    • Rotary blood pump flow spontaneously increases during exercise under constant pump speed: results of a chronic study
    • Akimoto T, Yamazaki K, Litwak P, etal. Rotary blood pump flow spontaneously increases during exercise under constant pump speed: results of a chronic study. Artif Organs 1999;23:797-801.
    • (1999) Artif Organs , vol.23 , pp. 797-801
    • Akimoto, T.1    Yamazaki, K.2    Litwak, P.3
  • 20
    • 31544453866 scopus 로고    scopus 로고
    • First clinical experience with an automatic control system for rotary blood pumps during ergometry and right-heart catheterization
    • Schima H, Vollkron M, Jantsch U, etal. First clinical experience with an automatic control system for rotary blood pumps during ergometry and right-heart catheterization. J Heart Lung Transplant 2006;25:167-73.
    • (2006) J Heart Lung Transplant , vol.25 , pp. 167-173
    • Schima, H.1    Vollkron, M.2    Jantsch, U.3
  • 21
    • 0344825781 scopus 로고    scopus 로고
    • Exercise after heart transplantation
    • Marconi C, Marzorati M. Exercise after heart transplantation. Eur J Appl Physiol 2003;90:250-9.
    • (2003) Eur J Appl Physiol , vol.90 , pp. 250-259
    • Marconi, C.1    Marzorati, M.2
  • 22
    • 25844436253 scopus 로고    scopus 로고
    • Differential exercise performance on ventricular assist device support
    • Simon M, Kormos R, Gorcsan J, etal. Differential exercise performance on ventricular assist device support. J Heart Lung Transplant 2005;24:1506-12.
    • (2005) J Heart Lung Transplant , vol.24 , pp. 1506-1512
    • Simon, M.1    Kormos, R.2    Gorcsan, J.3
  • 23
    • 0028298820 scopus 로고
    • Central and peripheral limitations to upright exercise in untrained cardiac transplant recipients
    • Kao AC, Van Trigt P 3rd, Shaeffer-McCall GS, etal. Central and peripheral limitations to upright exercise in untrained cardiac transplant recipients. Circulation 1994;89:2605-15.
    • (1994) Circulation , vol.89 , pp. 2605-2615
    • Kao, A.C.1    Van Trigt 3rd, P.2    Shaeffer-McCall, G.S.3
  • 24
    • 0026656482 scopus 로고
    • Effects of aging, sex, and physical training on cardiovascular responses to exercise
    • Ogawa T, Spina RJ, Martin WH 3rd, etal. Effects of aging, sex, and physical training on cardiovascular responses to exercise. Circulation 1992;86:494-503.
    • (1992) Circulation , vol.86 , pp. 494-503
    • Ogawa, T.1    Spina, R.J.2    Martin 3rd, W.H.3
  • 25
    • 0033984879 scopus 로고    scopus 로고
    • Cardiopulmonary exercise testing for prognosis in chronic heart failure: continuous and independent prognostic value from VE/VCO(2) slope and peak VO(2)
    • Francis DP, Shamim W, Davies LC, etal. Cardiopulmonary exercise testing for prognosis in chronic heart failure: continuous and independent prognostic value from VE/VCO(2) slope and peak VO(2). Eur Heart J 2000;21:154-61.
    • (2000) Eur Heart J , vol.21 , pp. 154-161
    • Francis, D.P.1    Shamim, W.2    Davies, L.C.3
  • 27
    • 12344333507 scopus 로고    scopus 로고
    • Oxygen uptake efficiency slope, a new submaximal parameter in evaluating exercise capacity in chronic heart failure patients
    • Van Laethem C, Bartunek J, Goethals M, Nellens P, Andries E, Vanderheyden M. Oxygen uptake efficiency slope, a new submaximal parameter in evaluating exercise capacity in chronic heart failure patients. Am Heart J 2005;149:175-80.
    • (2005) Am Heart J , vol.149 , pp. 175-180
    • Van Laethem, C.1    Bartunek, J.2    Goethals, M.3    Nellens, P.4    Andries, E.5    Vanderheyden, M.6
  • 28
    • 34547455264 scopus 로고    scopus 로고
    • The minute ventilation/carbon dioxide production slope is prognostically superior to the oxygen uptake efficiency slope
    • Arena R, Myers J, Hsu L, etal. The minute ventilation/carbon dioxide production slope is prognostically superior to the oxygen uptake efficiency slope. J Card Fail 2007;13:462-9.
    • (2007) J Card Fail , vol.13 , pp. 462-469
    • Arena, R.1    Myers, J.2    Hsu, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.