메뉴 건너뛰기




Volumn 7, Issue 4, 2011, Pages 237-241

Tunnelled internal jugular vein catheters with taurolidine lock: An acceptable challenge to arterio-venous fistula in 70 years old haemodialyzed patients: A prospective pilot study;Les cathéters jugulaires internes tunnellisés avec verrou antiseptique par taurolidine : une alternative acceptable aux fistules artérioveineuses chez les hémodialysés de plus de 70 ans : résultats d'une étude pilote prospective

Author keywords

Arteriovenous fistula; Catheter; Haemodialysis; Prospective; Taurolidine

Indexed keywords

ALBUMIN; HEPARIN; TAUROLIDINE;

EID: 79960159268     PISSN: 17697255     EISSN: 18729177     Source Type: Journal    
DOI: 10.1016/j.nephro.2011.04.001     Document Type: Article
Times cited : (3)

References (11)
  • 1
    • 0033042819 scopus 로고    scopus 로고
    • The hemodialysis catheter conundrum: Hate living with them, but can't live without them
    • DOI 10.1046/j.1523-1755.1999.00512.x
    • S.J. Schwab, and G. Beathard The haemodialysis catheter conundrum: hate living this, but can't live without them Kidney Int 56 1999 1 17 (Pubitemid 29300516)
    • (1999) Kidney International , vol.56 , Issue.1 , pp. 1-17
    • Schwab, S.J.1    Beathard, G.2
  • 2
    • 0032822611 scopus 로고    scopus 로고
    • Haemodialysis catheter-related infection: Time for action
    • DOI 10.1093/ndt/14.10.2288
    • B. Canaud Haemodialysis catheter-related infection: time for action Nephrol Dial Transplant 10 1999 2288 2290 (Pubitemid 29462459)
    • (1999) Nephrology Dialysis Transplantation , vol.14 , Issue.10 , pp. 2288-2290
    • Canaud, B.1
  • 3
    • 0034951584 scopus 로고    scopus 로고
    • Infections complications of the hemodialysis access
    • G.M. Nassar, and J.C. Ayus Infections complications of the hemodialysis access Kidnez Int 60 2001 1 13
    • (2001) Kidnez Int , vol.60 , pp. 1-13
    • Nassar, G.M.1    Ayus, J.C.2
  • 4
    • 26144465950 scopus 로고    scopus 로고
    • Efficacy of the Biolink catheter lock solution (CLStm) for Dialock R hemodialysis access port ant catheters-an in vitro model
    • March Atlanta
    • Mermel L, S. Parenteau. Efficacy of the Biolink catheter lock solution (CLStm) for Dialock R hemodialysis access port ant catheters-an in vitro model. Poster at the international conference on Nosocomial and Healthcare Associated Infections. March 2000, Atlanta.
    • (2000) International Conference on Nosocomial and Healthcare Associated Infections
    • Mermel, L.1    Parenteau, S.2
  • 6
    • 0035162149 scopus 로고    scopus 로고
    • Two years' experience with Dialock® and CLS™ (A new antimicrobial lock solution)
    • DOI 10.1159/000046950
    • K. Sodemannn, H.D. Polasckeff, and B. Feldmer Two years' experience with DialockR and CLStm (a new antimicrobial lock solution) Blood Purif 19 2001 251 254 (Pubitemid 32041363)
    • (2001) Blood Purification , vol.19 , Issue.2 , pp. 251-254
    • Sodemann, K.1    Polaschegg, H.-D.2    Feldmer, B.3
  • 7
    • 0034118234 scopus 로고    scopus 로고
    • Activities of Taurolidin in vitro and in experimental enterococcal endocarditis
    • C. Torres Viera Activities of Taurolidin in vitro and in experimental enterococcal endocarditis Antimicrob Agents Chemother 44 6 2000 1720 1724
    • (2000) Antimicrob Agents Chemother , vol.44 , Issue.6 , pp. 1720-1724
    • Torres Viera, C.1
  • 8
    • 0036186802 scopus 로고    scopus 로고
    • Management of hemodialysis catheter-related bacteremia with an adjunctive antibiotic lock solution
    • DOI 10.1046/j.1523-1755.2002.00201.x
    • Z. Krishnasami, D. Carlton, L. Bimbo, M.E. Taylor, D.F. Balkovetz, and J. Barker Management of hemodialysis catheter-related bacteremia with an adjunctive antibiotic lock solution Kidney Int. 61 2002 1136 1142 (Pubitemid 34175482)
    • (2002) Kidney International , vol.61 , Issue.3 , pp. 1136-1142
    • Krishnasami, Z.1    Carlton, D.2    Bimbo, L.3    Taylor, M.E.4    Balkovetz, D.F.5    Barker, J.6    Allon, M.7
  • 9
    • 0036007330 scopus 로고    scopus 로고
    • Prevention of hemodialysis catheter-related bloodstream infection using an antimicrobial lock
    • DOI 10.1159/000046990
    • F. Quarello, and G. Forneris Prevention haemodialysis catheter related bloodstream infection using an antimicrobial lock Blood Purif 20 2002 87 92 (Pubitemid 34102513)
    • (2002) Blood Purification , vol.20 , Issue.1 , pp. 87-92
    • Quarello, F.1    Forneris, G.2
  • 11
    • 67650091161 scopus 로고    scopus 로고
    • Une stratégie efficace pour diminuer l'utilisation et les complications des cathéters veineux centraux tunnelisés en hémodialyse
    • G. Jean, T. Vanel, E. Bresson, J.C. Terrat, J.M. Hurot, and C. Lorriaux Une stratégie efficace pour diminuer l'utilisation et les complications des cathéters veineux centraux tunnelisés en hémodialyse Nephrol Ther 5 2009 280 286
    • (2009) Nephrol Ther , vol.5 , pp. 280-286
    • Jean, G.1    Vanel, T.2    Bresson, E.3    Terrat, J.C.4    Hurot, J.M.5    Lorriaux, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.