-
1
-
-
26444439151
-
Pediatric cardiopulmonary bypass devices: Trends in device use for cardiopulmonary bypass and postcardiotomy support
-
DOI 10.1097/01.mat.0000180399.24938.a5
-
Groom RC. Pediatric cardiopulmonary bypass devices: trends in device use for cardiopulmonary bypass and post-cardiotomy support. ASAIO J 2005; 51(5): 525-529. (Pubitemid 41434235)
-
(2005)
ASAIO Journal
, vol.51
, Issue.5
, pp. 525-529
-
-
Groom, R.C.1
-
2
-
-
78649612553
-
Evolution of the ECLS circuitry [Guest Editorial]
-
Palanzo D, Qiu F, Baer L, Clark JB, Myers JL, Ul̈ndar A. Evolution of the ECLS circuitry [Guest Editorial]. Artificial Organs 2010; 34(11): 869-873.
-
(2010)
Artificial Organs
, vol.34
, Issue.11
, pp. 869-873
-
-
Palanzo, D.1
Qiu, F.2
Baer, L.3
Clark, J.B.4
Myers, J.L.5
Ul̈ndar, A.6
-
3
-
-
24944567494
-
Hemolytic characteristics of three commercially available centrifugal blood pumps
-
DOI 10.1097/01.PCC.0000163282.63992.13
-
Lawson DS, Ing R, Cheifetz IM, et al. Hemolytic characteristics of three commercially available centrifugal blood pumps. Pediatr Crit Care Med 2005; 6(5): 573-577. (Pubitemid 41306761)
-
(2005)
Pediatric Critical Care Medicine
, vol.6
, Issue.5
, pp. 573-577
-
-
Lawson, D.S.1
Ing, R.2
Cheifetz, I.M.3
Walczak, R.4
Craig, D.5
Schulman, S.6
Kern, F.7
Shearer, I.R.8
Lodge, A.9
Jaggers, J.10
-
4
-
-
2342664194
-
Pump-induced haemolysis: A comparison of short-term ventricular assist devices
-
DOI 10.1191/0267659104pf729oa
-
Bennett M, Horton S, Thuys C, Augustin S, Rosenberg M, Brizard C. Pump-induced haemolysis: a comparison of short-term ventricular assist devices. Perfusion 2004; 19(2): 107-111. (Pubitemid 38607513)
-
(2004)
Perfusion
, vol.19
, Issue.2
, pp. 107-111
-
-
Bennett, M.1
Horton, S.2
Thuys, C.3
Augustin, S.4
Rosenberg, M.5
Brizard, C.6
-
5
-
-
26444519934
-
Elimination of adverse leakage flow in a miniature pediatric centrifugal blood pump by computational fluid dynamics-based design optimization
-
DOI 10.1097/01.mat.0000178966.79876.3d
-
Wu J, Antaki JF, Wagner WR, Snyder TA, Paden BE, Borovetz HS. Elimination of adverse leakage flow in a miniature pediatric centrifugal blood pump by computational fluid dynamics-based design optimization. ASAIO J 2005; 51(5): 636-643. (Pubitemid 41434253)
-
(2005)
ASAIO Journal
, vol.51
, Issue.5
, pp. 636-643
-
-
Wu, J.1
Antaki, J.F.2
Wagner, W.R.3
Snyder, T.A.4
Paden, B.E.5
Borovetz, H.S.6
-
6
-
-
77951897571
-
Mechanical performance comparison between Rotaflow and CentriMag centrifugal pumps in an adult ECLS model
-
Guan Y, Su X, McCoach R, Kunselman A, El-Banayosy A, Undar A. Mechanical performance comparison between Rotaflow and CentriMag centrifugal pumps in an adult ECLS model. Perfusion 2010; 25(2): 71-76.
-
(2010)
Perfusion
, vol.25
, Issue.2
, pp. 71-76
-
-
Guan, Y.1
Su, X.2
McCoach, R.3
Kunselman, A.4
El-Banayosy, A.5
Undar, A.6
-
7
-
-
78649599707
-
Pediatric extracorporeal life support systems: Education and training at Penn State Hershey Children's Hospital
-
McCoach R, Weaver B, Carney E, et al. Pediatric extracorporeal life support systems: education and training at Penn State Hershey Children's Hospital. Artificial Organs 2010; 34(11): 1023-1026.
-
(2010)
Artificial Organs
, vol.34
, Issue.11
, pp. 1023-1026
-
-
McCoach, R.1
Weaver, B.2
Carney, E.3
-
8
-
-
42049098604
-
Evaluation of oxygenators and centrifugal pumps for long-term pediatric extracorporeal membrane oxygenation
-
DOI 10.1177/0267659107086270
-
Thiara AP, Hoel TN, Kristiansen F, Karlsen HM, Fiane AE, Svennevig JL. Evaluation of oxygenators and centrifugal pumps for long-term pediatric extracorporeal membrane oxygenation. Perfusion 2007; 22(5): 323-326. (Pubitemid 351516043)
-
(2007)
Perfusion
, vol.22
, Issue.5
, pp. 323-326
-
-
Thiara, A.P.S.1
Hoel, T.N.2
Kristianson, F.3
Karlsen, H.M.4
Fiane, A.E.5
Svennevig, J.L.6
-
9
-
-
18144382225
-
Postoperative mechanical circulatory support with Biomedicus centrifugal pump
-
Mert M, Akcevin A, Yildiz CE, Suzer K. Postoperative mechanical circulatory support with Biomedicus centrifugal pump. Asian Cardiovasc Thorac Ann 2005; 13(1): 38-4l.
-
(2005)
Asian Cardiovasc Thorac Ann
, vol.13
, Issue.1
-
-
Mert, M.1
Akcevin, A.2
Yildiz, C.E.3
Suzer, K.4
-
10
-
-
20144382997
-
Outcomes of congenital heart surgery patients after extracorporeal life support at Texas Children's Hospital
-
DOI 10.1111/j.1525-1594.2004.07378.x
-
UL̈ndar A, McKenzie ED, McGarry MC, et al. Outcomes of congenital heart surgery patients after extracorporeal life support at Texas Children's Hospital. Artif Organs 2004; 28(10): 963-966. (Pubitemid 40394482)
-
(2004)
Artificial Organs
, vol.28
, Issue.10
, pp. 963-966
-
-
Undar, A.1
McKenzie, E.D.2
McGarry, M.C.3
Owens, W.R.4
Surprise, D.L.5
Kilpack, V.D.6
Mueller, M.W.7
Stayer, S.A.8
Andropoulos, D.B.9
Towbin, J.A.10
Fraser Jr., C.D.11
-
11
-
-
3142771911
-
Mechanical circulatory support: Reality and dreams experience of a single center
-
Weitkemper HH, El-Banayosy A, Arusoglu L, Sarnowski P, Körfer R. Mechanical circulatory support: reality and dreams experience of a single center. J Extra Corpor Technol 2004; 36(2): 169-173. (Pubitemid 38924745)
-
(2004)
Journal of Extra-Corporeal Technology
, vol.36
, Issue.2
, pp. 169-173
-
-
Weitkemper, H.-H.1
El-Banayosy, A.2
Arusoglu, L.3
Sarnowski, P.4
Korfer, R.5
-
12
-
-
38349098665
-
Extracorporeal membrane oxygenation with a poly-methylpentene oxygenator (Quadrox D). The experience of a single Italian centre in adult patients with refractory cardiogenic shock
-
Formica F, Avalli L, Martino A, et al. Extracorporeal membrane oxygenation with a poly-methylpentene oxygenator (Quadrox D). The experience of a single Italian centre in adult patients with refractory cardiogenic shock. ASAIO J 2008; 54(1): 89-94.
-
(2008)
ASAIO J
, vol.54
, Issue.1
, pp. 89-94
-
-
Formica, F.1
Avalli, L.2
Martino, A.3
-
13
-
-
1642407635
-
D oxygenator for ECMO
-
DOI 10.1191/0267659104pf702oa
-
Horton S, Thuys C, Bennett M, Augustin S, Rosenberg M, Brizard C. Experience with the Jostra Rotaflow and QuadroxD oxygenator for ECMO. Perfusion 2004; 19(1): 17-23. (Pubitemid 38386645)
-
(2004)
Perfusion
, vol.19
, Issue.1
, pp. 17-23
-
-
Horton, S.1
Thuys, C.2
Bennett, M.3
Augustin, S.4
Rosenberg, M.5
Brizard, C.6
-
14
-
-
33846882847
-
Hydrodynamic performance and heat generation by centrifugal pumps
-
DOI 10.1177/0267659106074003
-
Ganushchak Y, van Marken Lichtenbelt W, van der Nagel T, de Jong DS. Hydrodynamic performance and heat generation by centrifugal pumps. Perfusion 2006; 21(6): 373-379. (Pubitemid 46218366)
-
(2006)
Perfusion
, vol.21
, Issue.6
, pp. 373-379
-
-
Ganushchak, Y.1
Van Marken Lichtenbelt, W.2
Van Der Nagel, T.3
De Jong, D.S.4
-
15
-
-
67650491595
-
Effects of the pulsatile flow settings on pulsatile waveforms and hemodynamic energy in a PediVAS centrifugal pump
-
Wang S, Rider AR, Kunselman AR, Richardson JS, Dasse KA, Ündar A. Effects of the pulsatile flow settings on pulsatile waveforms and hemodynamic energy in a PediVAS centrifugal pump. ASAIO J 2009; 55(3): 271-276.
-
(2009)
ASAIO J
, vol.55
, Issue.3
, pp. 271-276
-
-
Wang, S.1
Rider, A.R.2
Kunselman, A.R.3
Richardson, J.S.4
Dasse, K.A.5
Ündar, A.6
-
16
-
-
55949133476
-
Early experience with the Levitronix Centrimag device for extra-corporeal membrane oxygenation following lung transplantation
-
Khan NU, Al-Aloul M, Shah R, Yonan N. Early experience with the Levitronix Centrimag device for extra-corporeal membrane oxygenation following lung transplantation. Eur J Cardiothorac Surg 2008; 34(6): 1262-1264.
-
(2008)
Eur J Cardiothorac Surg
, vol.34
, Issue.6
, pp. 1262-1264
-
-
Khan, N.U.1
Al-Aloul, M.2
Shah, R.3
Yonan, N.4
-
17
-
-
36649009139
-
Assessment of hydraulic performance and biocompatibility of a MagLev centrifugal pump system designed for pediatric cardiac or cardiopulmonary support
-
DOI 10.1097/MAT.0b013e31815dbf66, PII 0000248020071100000026
-
Dasse KA, Gellman B, Kameneva MV, et al. Assessment of hydraulic performance and biocompatibility of a MagLev centrifugal pump system designed for pediatric cardiac or cardiopulmonary support. ASAIO J 2007; 53(6): 771-777. (Pubitemid 350193189)
-
(2007)
ASAIO Journal
, vol.53
, Issue.6
, pp. 771-777
-
-
Dasse, K.A.1
Gellman, B.2
Kameneva, M.V.3
Woolley, J.R.4
Johnson, C.A.5
Gempp, T.6
Marks, J.D.7
Kent, S.8
Koert, A.9
Richardson, J.S.10
Franklin, S.11
Snyder, T.A.12
Wearden, P.13
Wagner, W.R.14
Gilbert, R.J.15
Borovetz, H.S.16
-
18
-
-
33644993283
-
Computational and experimental evaluation of the fluid dynamics and hemo-compatibility of the CentriMag blood pump
-
Zhang J, Gellman B, Koert A, et al. Computational and experimental evaluation of the fluid dynamics and hemo-compatibility of the CentriMag blood pump. Artif Organs 2006; 30(3): 168-177.
-
(2006)
Artif Organs
, vol.30
, Issue.3
, pp. 168-177
-
-
Zhang, J.1
Gellman, B.2
Koert, A.3
-
19
-
-
31544443524
-
Clinical performance with the Levitronix Centrimag short-term ventricular assist device
-
DOI 10.1016/j.healun.2005.08.019, PII S1053249805005656
-
De Robertis F, Birks EJ, Rogers P, Dreyfus G, Pepper JR, Khaghani A. Clinical performance with the Levitronix Centrimag short-term ventricular assist device. J Heart Lung Transplant 2006; 25(2): 181-186. (Pubitemid 43156369)
-
(2006)
Journal of Heart and Lung Transplantation
, vol.25
, Issue.2
, pp. 181-186
-
-
De Robertis, F.1
Birks, E.J.2
Rogers, P.3
Dreyfus, G.4
Pepper, J.R.5
Khaghani, A.6
|