Hemodynamic evaluation of arterial and venous cannulae performance in a simulated neonatal extracorporeal life support circuit

Author keywords

Arterial cannula; Extracorporeal life support; Flow range; Pressure drop; Venous cannula

Indexed keywords

WATER;

EID: 79960078047     PISSN: 02676591     EISSN: 1477111X     Source Type: Journal    
DOI: 10.1177/0267659111406768     Document Type: Article
Times cited : (24)

References (11)
  • 1
    • 79955950953 scopus 로고    scopus 로고
    • Extracorporeal Life Support Organization, International Summary. Ann Arbor, MI USA; July
    • Extracorporeal Life Support Organization. ECLS Registry Report, International Summary. Ann Arbor, MI, USA; July 2010.
    • (2010) ECLS Registry Report
  • 3
    • 79960094326 scopus 로고    scopus 로고
    • Extracorporeal life support systems: Alternate vs. conventional circuits
    • (in press) DOI: 10.1177/0267659110395060
    • Khan S, Vasavada R, Qiu F, Kunselman AR, Ündar A.Extracorporeal life support systems: alternate vs. conventional circuits. Perfusion 2011. (in press) DOI: 10.1177/0267659110395060
    • (2011) Perfusion
    • Khan, S.1    Vasavada, R.2    Qiu, F.3    Kunselman, A.R.4    Ündar, A.5
  • 4
    • 78249267574 scopus 로고    scopus 로고
    • Improved outcomes of paediatric extracorporeal support associated with technology change
    • Sivarajan VB, Best D, Brizard CP, et al. Improved outcomes of paediatric extracorporeal support associated with technology change. Interact Cardiovasc Thorac Surg 2010; 11: 400-405.
    • (2010) Interact Cardiovasc Thorac Surg , vol.11 , pp. 400-405
    • Sivarajan, V.B.1    Best, D.2    Brizard, C.P.3
  • 5
    • 79960093340 scopus 로고    scopus 로고
    • An investigational study of minimum rotational pump speed to avoid retrograde flow in three centrifugal pumps in a pediatric extracorporeal life support model
    • Jan 12. [Epub ahead of print] DOI: 10.1177/0267659110394712
    • Clark JB, Guan Y, McCoach R, Kunselman AR, Myers JL, Ündar A. An investigational study of minimum rotational pump speed to avoid retrograde flow in three centrifugal pumps in a pediatric extracorporeal life support model. Perfusion. 2011 Jan 12. [Epub ahead of print] DOI: 10.1177/0267659110394712
    • (2011) Perfusion
    • Clark, J.B.1    Guan, Y.2    McCoach, R.3    Kunselman, A.R.4    Myers, J.L.5    Ündar, A.6
  • 6
    • 77951897571 scopus 로고    scopus 로고
    • Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model
    • Guan YL, Su XW, McCoach R, Kunselman AR, El-Banayosy A, Ündar A. Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model. Perfusion 2010; 25; 71-76.
    • (2010) Perfusion , vol.25 , pp. 71-76
    • Guan, Y.L.1    Su, X.W.2    McCoach, R.3    Kunselman, A.R.4    El-Banayosy, A.5    Ündar, A.6
  • 7
    • 70450278669 scopus 로고    scopus 로고
    • Comparison of two types of neonatal extracorporeal life support systems with pulsatile and nonpulsatile flow
    • Haines N, Wang S, Myers JL, Ündar A. Comparison of two types of neonatal extracorporeal life support systems with pulsatile and nonpulsatile flow. Artif Organs 2009; 33: 958-966.
    • (2009) Artif Organs , vol.33 , pp. 958-966
    • Haines, N.1    Wang, S.2    Myers, J.L.3    Ündar, A.4
  • 8
    • 77950882778 scopus 로고    scopus 로고
    • Comparison of perfusion quality in hollow-fiber membrane oxygenators for neonatal extracorporeal life support
    • Talor J, Yee S, Rider A, Kunselman AR, Guan YL, Ündar A. Comparison of perfusion quality in hollow-fiber membrane oxygenators for neonatal extracorporeal life support. Artif Organs 2010: 34: E110-116.
    • (2010) Artif Organs , vol.34
    • Talor, J.1    Yee, S.2    Rider, A.3    Kunselman, A.R.4    Guan, Y.L.5    Ündar, A.6
  • 9
    • 78649552760 scopus 로고    scopus 로고
    • Impact of the length of the tubing on hemodynamics in a simulated neonatal ECLS circuit
    • Qiu F, Uluer MC, Kunselman A, Clark JB, Myers JL,Ündar A. Impact of the length of the tubing on hemodynamics in a simulated neonatal ECLS circuit. Artif Organs 2010; 34: 1003-1009.
    • (2010) Artif Organs , vol.34 , pp. 1003-1009
    • Qiu, F.1    Uluer, M.C.2    Kunselman, A.3    Clark, J.B.4    Myers, J.L.5    Ündar, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.