메뉴 건너뛰기




Volumn 6, Issue 3, 2011, Pages 225-230

PSD modifications of FHRV due to interpolation and CTG storage rate

Author keywords

Cardiotocography; FHRV; Lomb method; Sympatho vagal balance

Indexed keywords

DIGITAL STORAGE; FREQUENCY ESTIMATION; HEART; POWER SPECTRAL DENSITY; SPECTRAL DENSITY;

EID: 79959990101     PISSN: 17468094     EISSN: 17468108     Source Type: Journal    
DOI: 10.1016/j.bspc.2010.10.002     Document Type: Conference Paper
Times cited : (18)

References (26)
  • 1
    • 33947168320 scopus 로고    scopus 로고
    • An algorithm for the recovery of fetal heart rate series from CTG data
    • DOI 10.1016/j.compbiomed.2006.06.003, PII S0010482506000886
    • M. Cesarelli, M. Romano, P. Bifulco, F. Fedele, and M. Bracale An algorithm for the recovery of fetal heart rate series from CTG data Comput. Biol. Med. 37 May (5) 2007 663 669 (Pubitemid 46400621)
    • (2007) Computers in Biology and Medicine , vol.37 , Issue.5 , pp. 663-669
    • Cesarelli, M.1    Romano, M.2    Bifulco, P.3    Fedele, F.4    Bracale, M.5
  • 3
    • 0344837758 scopus 로고    scopus 로고
    • Linear and nonlinear parameters for the analysis of fetal heart rate signal from cardiotocographic recordings
    • M.G. Signorini, G. Magenes, S. Cerutti, and D. Arduini Linear and nonlinear parameters for the analysis of fetal heart rate signal from cardiotocographic recordings IEEE Trans. Biomed. Eng. 50 March (3) 2003 365 375
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , Issue.MARCH 3 , pp. 365-375
    • Signorini, M.G.1    Magenes, G.2    Cerutti, S.3    Arduini, D.4
  • 4
    • 2342591420 scopus 로고    scopus 로고
    • Beat-to-beat detection of fetal heart rate: Doppler ultrasound cardiotocography compared to direct ECG cardiotocography in time and frequency domain
    • DOI 10.1088/0967-3334/25/2/015, PII S0967333404724363
    • C.H.L. Peters, E.D.M. Ten Broeke, P. Andriessen, B. Vermeulen, R.C.M. Berendsen, P.F.F. Wijn, and S.G. Oei Beat-to-beat detection of fetal heart rate: Doppler ultrasound cardiotocography compared to direct ECG cardiotocography in time and frequency domain Physiol. Meas. 25 2004 585 593 (Pubitemid 38568942)
    • (2004) Physiological Measurement , vol.25 , Issue.2 , pp. 585-593
    • Peters, C.H.L.1    Ten Broeke, E.D.M.2    Andriessen, P.3    Vermeulen, B.4    Berendsen, R.C.M.5    Wijn, P.F.F.6    Oei, S.G.7
  • 9
    • 0032101304 scopus 로고    scopus 로고
    • Power spectral density of unevenly sampled data by least-square analysis: Performance and application to heart rate signals
    • P. Laguna, G.B. Moody, and R.G. Mark Power spectral density of unevenly sampled data by least-square analysis: performance and application to heart rate signals IEEE Trans. Biomed. Eng. 45 6 June 1998
    • (1998) IEEE Trans. Biomed. Eng. , vol.45 , Issue.6
    • Laguna, P.1    Moody, G.B.2    Mark, R.G.3
  • 11
    • 0027809531 scopus 로고
    • Spectral analysis of heart rate without resampling
    • G.B. Moody Spectral analysis of heart rate without resampling Comput. Cardiol. 1993 715 718
    • (1993) Comput. Cardiol. , pp. 715-718
    • Moody, G.B.1
  • 12
    • 0033813314 scopus 로고    scopus 로고
    • Spectral information changes in obtaining heart rate variability from tachometer R-R interval signals
    • S.S. Abeysekera, U.R. Abeyratne, and S.B. Goh Spectral information changes in obtaining heart rate variability from tachometer R-R interval signals Crit. Rev. Biomed. Eng. 28 1-2 2000 149 155
    • (2000) Crit. Rev. Biomed. Eng. , vol.28 , Issue.12 , pp. 149-155
    • Abeysekera, S.S.1    Abeyratne, U.R.2    Goh, S.B.3
  • 13
    • 0028501030 scopus 로고
    • Heart rate variability spectra based on non-equidistant sampling: The spectrum of counts and the instantaneous heart rate spectrum
    • H.G. Van Steenis, J.H.M. Tulen, and L.J.M. Mulder Heart rate variability spectra based on non-equidistant sampling: the spectrum of counts and the instantaneous heart rate spectrum Med. Eng. Phys. September (16) 1994 355 362 (Pubitemid 24281626)
    • (1994) Medical Engineering and Physics , vol.16 , Issue.5 , pp. 355-362
    • Van Steenis, H.G.1    Tulen, J.H.M.2    Mulder, L.J.M.3
  • 15
    • 59649119146 scopus 로고    scopus 로고
    • Comparison of short term variability indexes in cardiotocographic foetal monitoring
    • M. Cesarelli, M. Romano, and P. Bifulco Comparison of short term variability indexes in cardiotocographic foetal monitoring Comput. Biol. Med. 39 2 2009 106 118
    • (2009) Comput. Biol. Med. , vol.39 , Issue.2 , pp. 106-118
    • Cesarelli, M.1    Romano, M.2    Bifulco, P.3
  • 16
    • 0030033222 scopus 로고    scopus 로고
    • Estimation of the power spectral density in nonstationary cardiovascular time series: Assessing the role of the time-frequency representation (TFR)
    • S. Pola, A. Macerata, M. Edmin, and C. Marchesi Estimation of the power spectral density in nonstationary cardiovascular time series: assessing the role of the time-frequency representation (TFR) IEEE Trans. Biomed. Eng. 43. January (1) 1996
    • (1996) IEEE Trans. Biomed. Eng. , vol.43 , Issue.JANUARY 1
    • Pola, S.1    MacErata, A.2    Edmin, M.3    Marchesi, C.4
  • 18
    • 33748319101 scopus 로고
    • Least-squares frequency analysis of unequally spaced data
    • N.R. Lomb Least-squares frequency analysis of unequally spaced data Astrophys. Space Sci. 39 1976 447 462
    • (1976) Astrophys. Space Sci. , vol.39 , pp. 447-462
    • Lomb, N.R.1
  • 19
    • 0001135997 scopus 로고
    • Studies in astronomical time series analysis. II. Statistical aspects of spectral analysis of unevenly spaced data
    • J.D. Scargle Studies in astronomical time series analysis. II. Statistical aspects of spectral analysis of unevenly spaced data Astrophys. J. 263 1982 835 853
    • (1982) Astrophys. J. , vol.263 , pp. 835-853
    • Scargle, J.D.1
  • 21
    • 12344308577 scopus 로고    scopus 로고
    • Quantifying errors in spectral estimates of HRV due to beat replacement and resampling
    • G.D. Clifford, and L. Tarassenko Quantifying errors in spectral estimates of HRV due to beat replacement and resampling IEEE Trans. Biomed. Eng. 52 April (4) 2005
    • (2005) IEEE Trans. Biomed. Eng. , vol.52 , Issue.APRIL 4
    • Clifford, G.D.1    Tarassenko, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.