-
1
-
-
33646371265
-
Comparison of Doppler ultrasound and direct electrocardiography acquisition techniques for quantification of fetal heart rate variability
-
Jezewski J., Wrobel J., and Horoba K. Comparison of Doppler ultrasound and direct electrocardiography acquisition techniques for quantification of fetal heart rate variability. IEEE Trans. Biomed. Eng. 53 5 (2006) 855-864
-
(2006)
IEEE Trans. Biomed. Eng.
, vol.53
, Issue.5
, pp. 855-864
-
-
Jezewski, J.1
Wrobel, J.2
Horoba, K.3
-
3
-
-
0344837758
-
Linear and nonlinear parameters for the analysis of fetal heart rate signal from cardiotocographic recordings
-
Signorini M.G., Magenes G., Cerutti S., and Arduini D. Linear and nonlinear parameters for the analysis of fetal heart rate signal from cardiotocographic recordings. IEEE Trans. Biomed. Eng. 50 3 (2003) 365-375
-
(2003)
IEEE Trans. Biomed. Eng.
, vol.50
, Issue.3
, pp. 365-375
-
-
Signorini, M.G.1
Magenes, G.2
Cerutti, S.3
Arduini, D.4
-
4
-
-
0029051327
-
-
FIGO Study Group on the Assessment of New Technology, FIGO News. Intrapartum surveillance: recommendations on current practice and overview of new developments, Int. J. Gynecol. Obstet. 49 (1995) 213-221.
-
FIGO Study Group on the Assessment of New Technology, FIGO News. Intrapartum surveillance: recommendations on current practice and overview of new developments, Int. J. Gynecol. Obstet. 49 (1995) 213-221.
-
-
-
-
5
-
-
23044461997
-
Visual analysis of antepartum fetal heart rate tracings: inter- and intra-observer agreement and impact of knowledge of neonatal outcome
-
Figueras F., Albela S., Bonino S., Palacio M., Barrau E., Hernandez S., Casellas C., Coll O., and Cararach V. Visual analysis of antepartum fetal heart rate tracings: inter- and intra-observer agreement and impact of knowledge of neonatal outcome. J. Perinat. Med. 33 3 (2005) 241-245
-
(2005)
J. Perinat. Med.
, vol.33
, Issue.3
, pp. 241-245
-
-
Figueras, F.1
Albela, S.2
Bonino, S.3
Palacio, M.4
Barrau, E.5
Hernandez, S.6
Casellas, C.7
Coll, O.8
Cararach, V.9
-
6
-
-
0036583263
-
A computer system for the numerical analysis of nonstress tests
-
Pardey J., Moulden M., and Redman C.W.G. A computer system for the numerical analysis of nonstress tests. Am. J. Obstet. Gynecol. 186 5 (2002) 1095-1103
-
(2002)
Am. J. Obstet. Gynecol.
, vol.186
, Issue.5
, pp. 1095-1103
-
-
Pardey, J.1
Moulden, M.2
Redman, C.W.G.3
-
10
-
-
0008368124
-
Training a neural network to recognize artifacts and decelerations in cardiotocograms
-
B. Rosen, D. Soriano, T. Bylander, H. Ortiz-Zuazaga, B. Schifrin, Training a neural network to recognize artifacts and decelerations in cardiotocograms, in: AAAI Spring Symposium on Artificial Intelligence in Medicine (1996).
-
(1996)
AAAI Spring Symposium on Artificial Intelligence in Medicine
-
-
Rosen, B.1
Soriano, D.2
Bylander, T.3
Ortiz-Zuazaga, H.4
Schifrin, B.5
-
11
-
-
11044232811
-
Identification of fetal sufference antepartum through a multiparametric analysis and a support vector machine
-
San Francisco, CA, USA
-
G. Magenes, L. Pedrinazzi, M.G. Signorini. Identification of fetal sufference antepartum through a multiparametric analysis and a support vector machine, in: Proceedings of the 26th Annual International Conference of the IEEE EMBS San Francisco, CA, USA. (2004).
-
(2004)
Proceedings of the 26th Annual International Conference of the IEEE EMBS
-
-
Magenes, G.1
Pedrinazzi, L.2
Signorini, M.G.3
-
12
-
-
0028310328
-
Quantification of the heart rate variability by spectral analysis of fetal well-being and fetal distress
-
Sibony O., Fouillot J.P., Benaoudia M., Benhalla A., Oury J.F., Sureau C., and Blot P. Quantification of the heart rate variability by spectral analysis of fetal well-being and fetal distress. Eur. J. Obstet. Gynecol. Reprod. Biol. 54 (1994) 103-108
-
(1994)
Eur. J. Obstet. Gynecol. Reprod. Biol.
, vol.54
, pp. 103-108
-
-
Sibony, O.1
Fouillot, J.P.2
Benaoudia, M.3
Benhalla, A.4
Oury, J.F.5
Sureau, C.6
Blot, P.7
-
14
-
-
0036804779
-
Problems with intrapartum fetal heart rate monitoring interpretation and patient management
-
Freeman R.K. Problems with intrapartum fetal heart rate monitoring interpretation and patient management. Obstet. Gynecol. 100 4 (2002) 813-826
-
(2002)
Obstet. Gynecol.
, vol.100
, Issue.4
, pp. 813-826
-
-
Freeman, R.K.1
-
15
-
-
0026744996
-
Short-term fetal heart rate variation, decelerations, and umbilical flow velocity waveforms before labor
-
Dawes G.S., Moulden M., and Redman C.W. Short-term fetal heart rate variation, decelerations, and umbilical flow velocity waveforms before labor. Obstet. Gynecol. 80 (1992) 673-678
-
(1992)
Obstet. Gynecol.
, vol.80
, pp. 673-678
-
-
Dawes, G.S.1
Moulden, M.2
Redman, C.W.3
-
16
-
-
0017256618
-
Fetal heart deceleration patterns in relation to asphyxia and weight-gestational age percentile of the fetus
-
Low J.A., Pancham S.R., and Worthington D. Fetal heart deceleration patterns in relation to asphyxia and weight-gestational age percentile of the fetus. Obstet. Gynecol. 47 (1976) 14-20
-
(1976)
Obstet. Gynecol.
, vol.47
, pp. 14-20
-
-
Low, J.A.1
Pancham, S.R.2
Worthington, D.3
-
17
-
-
0036854897
-
Fetal heart rate parameters predictive of neonatal outcome in the presence of a prolonged deceleration
-
Williams K.P., and Galerneau F. Fetal heart rate parameters predictive of neonatal outcome in the presence of a prolonged deceleration. Obstet. Gynecol. 100 5 part 1 (2002) 951-954
-
(2002)
Obstet. Gynecol.
, vol.100
, Issue.5 PART 1
, pp. 951-954
-
-
Williams, K.P.1
Galerneau, F.2
-
18
-
-
0018928795
-
Analysis of heart rate and beat-to-beat variability: interval difference index
-
van Geijn H.P., Jongsma H.W., Haan J., and Eskes T.K.A.B. Analysis of heart rate and beat-to-beat variability: interval difference index. Am. J. Obstet. Gynecol. 138 3 (1980) 246-252
-
(1980)
Am. J. Obstet. Gynecol.
, vol.138
, Issue.3
, pp. 246-252
-
-
van Geijn, H.P.1
Jongsma, H.W.2
Haan, J.3
Eskes, T.K.A.B.4
-
19
-
-
0033135411
-
Interpretation of the electronic fetal heart rate during labor
-
Sweha A., and Hacker T.W. Interpretation of the electronic fetal heart rate during labor. Am. Acad. Fam. Physician 59 9 (1999) 2487-2500
-
(1999)
Am. Acad. Fam. Physician
, vol.59
, Issue.9
, pp. 2487-2500
-
-
Sweha, A.1
Hacker, T.W.2
-
20
-
-
0023818933
-
2 and neonatal heart rate patterns during normal postnatal adaptation and respiratory distress
-
2 and neonatal heart rate patterns during normal postnatal adaptation and respiratory distress. Early Hum. Dev. 16 (1998) 3-11
-
(1998)
Early Hum. Dev.
, vol.16
, pp. 3-11
-
-
Aarimaa, T.1
Oja, R.2
-
21
-
-
0025892159
-
System 8000: computerized antenatal fetal heart rate analysis
-
Dawes G.S., Moulden M., and Redman C.W.G. System 8000: computerized antenatal fetal heart rate analysis. J Perinat Med. 19 (1991) 47-51
-
(1991)
J Perinat Med.
, vol.19
, pp. 47-51
-
-
Dawes, G.S.1
Moulden, M.2
Redman, C.W.G.3
-
22
-
-
0017861734
-
Quantitative indices of short- and long-term heart rate variability
-
Organ L.W., Hawrylyshyn P.A., Goodwin J.W., Milligan J.E., and Bernstein A. Quantitative indices of short- and long-term heart rate variability. Am. J. Obstet. Gynecol. 130 (1978) 20
-
(1978)
Am. J. Obstet. Gynecol.
, vol.130
, pp. 20
-
-
Organ, L.W.1
Hawrylyshyn, P.A.2
Goodwin, J.W.3
Milligan, J.E.4
Bernstein, A.5
-
23
-
-
0015593615
-
Quantification of fetal beat-to-beat interval differences
-
Yeh S.Y., Forsythe A., and Hon E.H. Quantification of fetal beat-to-beat interval differences. Obstet. Gynecol. 41 3 (1973) 355-363
-
(1973)
Obstet. Gynecol.
, vol.41
, Issue.3
, pp. 355-363
-
-
Yeh, S.Y.1
Forsythe, A.2
Hon, E.H.3
-
24
-
-
0031128311
-
The effect of different sampling intervals on the measurements of intrapartum fetal heart rate variability
-
Wilcox M.A., Wang W., Sahota D.S., Dawkins R.R., Chung T.K.H., and Chang M.Z. The effect of different sampling intervals on the measurements of intrapartum fetal heart rate variability. Obstet. Gynecol. 89 4 (1997) 577-580
-
(1997)
Obstet. Gynecol.
, vol.89
, Issue.4
, pp. 577-580
-
-
Wilcox, M.A.1
Wang, W.2
Sahota, D.S.3
Dawkins, R.R.4
Chung, T.K.H.5
Chang, M.Z.6
-
25
-
-
12344308577
-
Quantifying errors in spectral estimates of HRV due to beat replacement and resampling
-
Clifford G.D., and Tarassenko L. Quantifying errors in spectral estimates of HRV due to beat replacement and resampling. IEEE Trans. Biomed. Eng. 52 4 (2005) 630-638
-
(2005)
IEEE Trans. Biomed. Eng.
, vol.52
, Issue.4
, pp. 630-638
-
-
Clifford, G.D.1
Tarassenko, L.2
-
26
-
-
0037340466
-
A dynamical model for generating synthetic electrocardiogram signals
-
McSharry P.E., Clifford G.D., Tarassenko L., and Smith L.A. A dynamical model for generating synthetic electrocardiogram signals. IEEE Trans. Biomed. Eng. 50 3 (2003) 289-294
-
(2003)
IEEE Trans. Biomed. Eng.
, vol.50
, Issue.3
, pp. 289-294
-
-
McSharry, P.E.1
Clifford, G.D.2
Tarassenko, L.3
Smith, L.A.4
-
27
-
-
33947168320
-
An algorithm for the recovery of fetal heart rate series from CTG data
-
Cesarelli M., Romano M., Bifulco P., Fedele F., and Bracale M. An algorithm for the recovery of fetal heart rate series from CTG data. Comput. Biol. Med. 37 5 (2007) 663-669
-
(2007)
Comput. Biol. Med.
, vol.37
, Issue.5
, pp. 663-669
-
-
Cesarelli, M.1
Romano, M.2
Bifulco, P.3
Fedele, F.4
Bracale, M.5
-
29
-
-
59649110972
-
-
Computer CardioTocoGrafo (2ctg). Application Guide ver. B.01. (2000)
-
Computer CardioTocoGrafo (2ctg). Application Guide ver. B.01. (2000)
-
-
-
-
30
-
-
0017350610
-
Diurnal respiratory and other rhythms of fetal heart rate in lambs
-
Dalton K.J., Dawes G.S., and Patrick J.E. Diurnal respiratory and other rhythms of fetal heart rate in lambs. Am. J. Obstet. Gynecol. 127 4 (1997) 414-424
-
(1997)
Am. J. Obstet. Gynecol.
, vol.127
, Issue.4
, pp. 414-424
-
-
Dalton, K.J.1
Dawes, G.S.2
Patrick, J.E.3
-
32
-
-
0019167359
-
Mechanisms of beat-to-beat variability in the heart rate of the neonatal lamb I. Influence of the autonomic nervous system
-
Zugaib M., Forsythe A.B., Nuwayhid B., Lieb S.M., Tabsh K., Erkkola R., Ushioda E., III Brinkman C.R., and Assali N.S. Mechanisms of beat-to-beat variability in the heart rate of the neonatal lamb I. Influence of the autonomic nervous system. Am. J. Obstet Gynecol. 138 4 (1980) 444-452
-
(1980)
Am. J. Obstet Gynecol.
, vol.138
, Issue.4
, pp. 444-452
-
-
Zugaib, M.1
Forsythe, A.B.2
Nuwayhid, B.3
Lieb, S.M.4
Tabsh, K.5
Erkkola, R.6
Ushioda, E.7
III Brinkman, C.R.8
Assali, N.S.9
-
33
-
-
0025826146
-
Short term variation in abnormal antenatal fetal heart rate records
-
Street P., Dawes G.S., Mulden M., and Redman C.W.G. Short term variation in abnormal antenatal fetal heart rate records. Am J Obstet. Gynecol 165 3 (1991) 515-523
-
(1991)
Am J Obstet. Gynecol
, vol.165
, Issue.3
, pp. 515-523
-
-
Street, P.1
Dawes, G.S.2
Mulden, M.3
Redman, C.W.G.4
-
34
-
-
0018362206
-
Fetal heart rtae variability: an approach to automated assessment
-
Huey J.R., Paul R.H., Hadjiev A.A., Jilek J., and Hon E.H. Fetal heart rtae variability: an approach to automated assessment. Am. J. Obstet. Gynecol. 134 (1979) 691-695
-
(1979)
Am. J. Obstet. Gynecol.
, vol.134
, pp. 691-695
-
-
Huey, J.R.1
Paul, R.H.2
Hadjiev, A.A.3
Jilek, J.4
Hon, E.H.5
-
35
-
-
34247183110
-
Heart rate variability in the fetus: a comparison of measures
-
Van Leeuwen P., Lange S., Geue D., and Gronemeyer D. Heart rate variability in the fetus: a comparison of measures. Biomed. Tech. (Berl) 52 1 (2007) 61-65
-
(2007)
Biomed. Tech. (Berl)
, vol.52
, Issue.1
, pp. 61-65
-
-
Van Leeuwen, P.1
Lange, S.2
Geue, D.3
Gronemeyer, D.4
|