메뉴 건너뛰기




Volumn 30, Issue 8, 2011, Pages 870-878

Inhaled nitric oxide after left ventricular assist device implantation: A prospective, randomized, double-blind, multicenter, placebo-controlled trial

(15)  Potapov, Evgenij a   Meyer, Dan b   Swaminathan, Madhav c   Ramsay, Michael d   El Banayosy, Aly e   Diehl, Christoph f   Veynovich, Bryan g   Gregoric, Igor D h   Kukucka, Marian a   Gromann, Tom W a   Marczin, Nandor i   Chittuluru, Kanti j   Baldassarre, James S j   Zucker, Mark J k   Hetzer, Roland a  


Author keywords

heart failure; heart assist device; nitric oxide; ventilation

Indexed keywords

NITRIC OXIDE; NITROGEN; PLACEBO;

EID: 79959984649     PISSN: 10532498     EISSN: 15573117     Source Type: Journal    
DOI: 10.1016/j.healun.2011.03.005     Document Type: Article
Times cited : (100)

References (25)
  • 1
    • 0035892018 scopus 로고    scopus 로고
    • Long-term mechanical left ventricular assistance for end-stage heart failure
    • E.A. Rose, A.C. Gelijns, and A.J. Moskowitz Long-term mechanical left ventricular assistance for end-stage heart failure N Engl J Med 345 2001 1435 1443
    • (2001) N Engl J Med , vol.345 , pp. 1435-1443
    • Rose, E.A.1    Gelijns, A.C.2    Moskowitz, A.J.3
  • 3
    • 33746717534 scopus 로고    scopus 로고
    • Right ventricular failure after left ventricular assist device insertion: Preoperative risk factors
    • L. Santambrogio, T. Bianchi, and M. Fuardo Right ventricular failure after left ventricular assist device insertion: preoperative risk factors Interact Cardiovasc Thorac Surg 5 2006 379 382
    • (2006) Interact Cardiovasc Thorac Surg , vol.5 , pp. 379-382
    • Santambrogio, L.1    Bianchi, T.2    Fuardo, M.3
  • 5
    • 44049094013 scopus 로고    scopus 로고
    • The Right Ventricular Failure Risk Score. A Pre-Operative Tool for Assessing the Risk of Right Ventricular Failure in Left Ventricular Assist Device Candidates
    • DOI 10.1016/j.jacc.2008.03.009, PII S0735109708010280
    • J.C. Matthews, T.M. Koelling, F.D. Pagani, and K.D. Aaronson The right ventricular failure risk score: a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates J Am Coll Cardiol 51 2008 2163 2172 (Pubitemid 351713685)
    • (2008) Journal of the American College of Cardiology , vol.51 , Issue.22 , pp. 2163-2172
    • Matthews, J.C.1    Koelling, T.M.2    Pagani, F.D.3    Aaronson, K.D.4
  • 6
    • 52949132558 scopus 로고    scopus 로고
    • Tricuspid annular motion as a predictor of severe right ventricular failure after left ventricular assist device implantation
    • S. Puwanant, K.K. Hamilton, and C.T. Klodell Tricuspid annular motion as a predictor of severe right ventricular failure after left ventricular assist device implantation J Heart Lung Transplant 27 2008 1102 1107
    • (2008) J Heart Lung Transplant , vol.27 , pp. 1102-1107
    • Puwanant, S.1    Hamilton, K.K.2    Klodell, C.T.3
  • 7
    • 57049174043 scopus 로고    scopus 로고
    • Risk score derived from pre-operative data analysis predicts the need for biventricular mechanical circulatory support
    • J.R. Fitzpatrick 3rd, J.R. Frederick, and V.M. Hsu Risk score derived from pre-operative data analysis predicts the need for biventricular mechanical circulatory support J Heart Lung Transplant 27 2008 1286 1292
    • (2008) J Heart Lung Transplant , vol.27 , pp. 1286-1292
    • Fitzpatrick III, J.R.1    Frederick, J.R.2    Hsu, V.M.3
  • 9
    • 57049100424 scopus 로고    scopus 로고
    • Tricuspid incompetence and geometry of the right ventricle as predictors of right ventricular function after implantation of a left ventricular assist device
    • E.V. Potapov, A. Stepanenko, and M. Dandel Tricuspid incompetence and geometry of the right ventricle as predictors of right ventricular function after implantation of a left ventricular assist device J Heart Lung Transplant 27 2008 1275 1281
    • (2008) J Heart Lung Transplant , vol.27 , pp. 1275-1281
    • Potapov, E.V.1    Stepanenko, A.2    Dandel, M.3
  • 10
    • 77949490707 scopus 로고    scopus 로고
    • Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: Incidence, risk factors, and effect on outcomes
    • R.L. Kormos, J.J. Teuteberg, and F.D. Pagani Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes J Thorac Cardiovasc Surg 139 2010 1316 1324
    • (2010) J Thorac Cardiovasc Surg , vol.139 , pp. 1316-1324
    • Kormos, R.L.1    Teuteberg, J.J.2    Pagani, F.D.3
  • 11
    • 74849116751 scopus 로고    scopus 로고
    • Effects of the HeartMate II continuous-flow left ventricular assist device on right ventricular function
    • S. Lee, F. Kamdar, and R. Madlon-Kay Effects of the HeartMate II continuous-flow left ventricular assist device on right ventricular function J Heart Lung Transplant 29 2010 209 215
    • (2010) J Heart Lung Transplant , vol.29 , pp. 209-215
    • Lee, S.1    Kamdar, F.2    Madlon-Kay, R.3
  • 13
    • 0030892739 scopus 로고    scopus 로고
    • Influence of inhaled nitric oxide on systemic flow and ventricular filling pressure in patients receiving mechanical circulatory assistance
    • J.M. Hare, S.K. Shernan, S.C. Body, E. Graydon, W.S. Colucci, and G.S. Couper Influence of inhaled nitric oxide on systemic flow and ventricular filling pressure in patients receiving mechanical circulatory assistance Circulation 95 1997 2250 2253 (Pubitemid 27191001)
    • (1997) Circulation , vol.95 , Issue.9 , pp. 2250-2253
    • Hare, J.M.1    Shernan, S.K.2    Body, S.C.3    Graydon, E.4    Colucci, W.S.5    Couper, G.S.6
  • 14
    • 0343683328 scopus 로고    scopus 로고
    • Nitric oxide inhalation in the treatment of right ventricular dysfunction following left ventricular assist device implantation
    • F. Wagner, M. Dandel, and G. Gunther Nitric oxide inhalation in the treatment of right ventricular dysfunction following left ventricular assist device implantation Circulation 96 1997 II-6
    • (1997) Circulation , vol.96 , pp. 6
    • Wagner, F.1    Dandel, M.2    Gunther, G.3
  • 15
    • 0041414497 scopus 로고    scopus 로고
    • Modulation of circulating endothelin-1 and big endothelin by nitric oxide inhalation following left ventricular assist device implantation
    • F.D. Wagner, S. Buz, C. Knosalla, R. Hetzer, and B. Hocher Modulation of circulating endothelin-1 and big endothelin by nitric oxide inhalation following left ventricular assist device implantation Circulation 108 Suppl 1 2003 II278 II284
    • (2003) Circulation , vol.108 , Issue.SUPPL 1
    • Wagner, F.D.1    Buz, S.2    Knosalla, C.3    Hetzer, R.4    Hocher, B.5
  • 19
    • 0034727386 scopus 로고    scopus 로고
    • Inhaled nitric oxide and prevention of pulmonary hypertension after congenital heart surgery: A randomised double-blind study
    • O.I. Miller, S.F. Tang, A. Keech, N.B. Pigott, E. Beller, and D.S. Celermajer Inhaled nitric oxide and prevention of pulmonary hypertension after congenital heart surgery: a randomised double-blind study Lancet 356 2000 1464 1469
    • (2000) Lancet , vol.356 , pp. 1464-1469
    • Miller, O.I.1    Tang, S.F.2    Keech, A.3    Pigott, N.B.4    Beller, E.5    Celermajer, D.S.6
  • 22
    • 12744271865 scopus 로고    scopus 로고
    • Collective review: Perioperative uses of inhaled nitric oxide in adults
    • M.C. Oz, and A. Ardehali Collective review: perioperative uses of inhaled nitric oxide in adults Heart Surg Forum 7 2004 E584 E589
    • (2004) Heart Surg Forum , vol.7
    • Oz, M.C.1    Ardehali, A.2
  • 23
    • 0026570626 scopus 로고
    • Influence of preoperative pulmonary artery pressure on mortality after heart transplantation: Testing of potential reversibility of pulmonary hypertension with nitroprusside is useful in defining a high risk group
    • A. Costard-Jackle, and M.B. Fowler Influence of preoperative pulmonary artery pressure on mortality after heart transplantation: testing of potential reversibility of pulmonary hypertension with nitroprusside is useful in defining a high risk group J Am Coll Cardiol 19 1992 48 54
    • (1992) J Am Coll Cardiol , vol.19 , pp. 48-54
    • Costard-Jackle, A.1    Fowler, M.B.2
  • 24
    • 0037636691 scopus 로고    scopus 로고
    • Patient selection for left ventricular assist device therapy
    • K.D. Aaronson, H. Patel, and F.D. Pagani Patient selection for left ventricular assist device therapy Ann Thorac Surg 75 2003 S29 S35
    • (2003) Ann Thorac Surg , vol.75
    • Aaronson, K.D.1    Patel, H.2    Pagani, F.D.3
  • 25
    • 0034898266 scopus 로고    scopus 로고
    • Revascularization of the occluded right coronary artery during left ventricular assist device implantation
    • DOI 10.1016/S1053-2498(01)00266-2, PII S1053249801002662
    • E.V. Potapov, R. Sodian, M. Loebe, T. Drews, S. Dreysse, and R. Hetzer Revascularization of the occluded right coronary artery during left ventricular assist device implantation J Heart Lung Transplant 20 2001 918 922 (Pubitemid 32737529)
    • (2001) Journal of Heart and Lung Transplantation , vol.20 , Issue.8 , pp. 918-922
    • Potapov, E.V.1    Sodian, R.2    Loebe, M.3    Drews, T.4    Dreysse, S.5    Hetzer, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.