메뉴 건너뛰기




Volumn 26, Issue 7, 2011, Pages 1481-1487

Studies with a miniaturized microwave induced plasma for element specific detection in gas chromatographic separations of halogenated hydrocarbons

Author keywords

[No Author keywords available]

Indexed keywords

ANALYTE CONCENTRATION; BROMINATED ALKANES; CAPILLARY GAS CHROMATOGRAPHY; CARRIER GAS FLOW; DETECTION LIMITS; ELEMENT SPECIFIC; EXCITATION TEMPERATURE; FERROCENES; GAS CHROMATOGRAPHIC PARAMETERS; GAS CHROMATOGRAPHIC SEPARATION; HALOGENATED HYDROCARBONS; HALOGENATED ORGANIC COMPOUNDS; HYPHENATED TECHNIQUES; INTERNAL STANDARDS; LIMITS OF DETECTION; MICROSTRIPES; MICROWAVE-INDUCED PLASMAS; OPTICAL EMISSION SPECTROMETRY; OVEN TEMPERATURE; PLASMA GAS; PLASMA GAS FLOW; RECOVERY RATE; TRANSFER LINES;

EID: 79959975950     PISSN: 02679477     EISSN: 13645544     Source Type: Journal    
DOI: 10.1039/c1ja10028a     Document Type: Article
Times cited : (9)

References (35)
  • 1
    • 84986529346 scopus 로고
    • Applications of gas chromatography with an atomic emission detector
    • P. L. Wylie B. D. Quimby Applications of gas chromatography with an atomic emission detector J. High Resolut. Chromatogr. 1989 12 813 818
    • (1989) J. High Resolut. Chromatogr. , vol.12 , pp. 813-818
    • Wylie, P.L.1    Quimby, B.D.2
  • 2
    • 0009385328 scopus 로고
    • Selective detectors in gas chromatography
    • M. Kreji M. Dressler Selective detectors in gas chromatography Chromatogr. Rev. 1970 13 1 59
    • (1970) Chromatogr. Rev. , vol.13 , pp. 1-59
    • Kreji, M.1    Dressler, M.2
  • 3
    • 2942571281 scopus 로고    scopus 로고
    • Gas chromatography/plasma spectrometry - An important analytical tool for elemental speciation studies
    • J. Wuilloud R. Wuilloud A. Vonderheide J. Caruso Gas chromatography/ plasma spectrometry - an important analytical tool for elemental speciation studies Spectrochim. Acta, Part B 2004 59 755 792
    • (2004) Spectrochim. Acta, Part B , vol.59 , pp. 755-792
    • Wuilloud, J.1    Wuilloud, R.2    Vonderheide, A.3    Caruso, J.4
  • 4
    • 0031271484 scopus 로고    scopus 로고
    • Speciation analysis by gas chromatography with plasma source spectrometric detection
    • PII S0584854797000931
    • R. Lobinski F. Adams Speciation analysis by gas chromatography with plasma source spectrometric detection Spectrochim. Acta, Part B 1997 52 1865 1903 (Pubitemid 127430204)
    • (1997) Spectrochimica Acta - Part B Atomic Spectroscopy , vol.52 , Issue.13 , pp. 1865-1903
    • Lobinski, R.1    Adams, F.C.2
  • 5
    • 0033075541 scopus 로고    scopus 로고
    • Low-power inductively coupled plasma source for element-selective atomic emission detection in gas chromatography
    • L. J. Jerrell M. R. Dunn J. E. Anderson H. B. Fannin Low-power inductively coupled plasma source for element-selective atomic emission detection in gas chromatography Appl. Spectrosc. 1999 53 245 248
    • (1999) Appl. Spectrosc. , vol.53 , pp. 245-248
    • Jerrell, L.J.1    Dunn, M.R.2    Anderson, J.E.3    Fannin, H.B.4
  • 6
    • 0036016412 scopus 로고    scopus 로고
    • Gas chromatography with inductively coupled plasma mass spectrometric detection in speciation analysis
    • DOI 10.1016/S0584-8547(02)00024-1, PII S0584854702000241
    • B. Bouyssiere J. Szpunar R. Lobinski Gas chromatography with inductively coupled plasma mass spectrometric detection in speciation analysis Spectrochim. Acta, Part B 2002 57 805 828 (Pubitemid 34624287)
    • (2002) Spectrochimica Acta - Part B Atomic Spectroscopy , vol.57 , Issue.5 , pp. 805-828
    • Bouyssiere, B.1    Szpunar, J.2    Lobinski, R.3
  • 7
    • 0031235221 scopus 로고    scopus 로고
    • Summary of a calibration method for the determination of volatile metal(loid) compounds in environmental gas samples by using gas chromatography-inductively coupled plasma mass spectrometry
    • J. Feldmann Summary of a calibration method for the determination of volatile metal(loid) compounds in environmental gas samples by using gas chromatography inductively coupled plasma mass spectrometry J. Anal. At. Spectrom. 1997 12 1069 1076 (Pubitemid 127589828)
    • (1997) Journal of Analytical Atomic Spectrometry , vol.12 , Issue.9 , pp. 1069-1076
    • Feldmann, J.1
  • 8
    • 49349133838 scopus 로고
    • Evaluation of a microwave-induced plasma in helium at atmospheric pressure as an element-selective detector for gas chromatography
    • C. Beenakker Evaluation of a microwave-induced plasma in helium at atmospheric pressure as an element-selective detector for gas chromatography Spectrochim. Acta, Part B 1977 32 173 187
    • (1977) Spectrochim. Acta, Part B , vol.32 , pp. 173-187
    • Beenakker, C.1
  • 9
    • 0000843647 scopus 로고
    • Gas chromatographic determination of phosphorus, sulfur and halogens using a water-cooled torch with reduced-pressure helium microwave-induced plasma mass spectrometry
    • W. C. Story J. A. Caruso Gas chromatographic determination of phosphorus, sulfur and halogens using a water-cooled torch with reduced-pressure helium microwave-induced plasma mass spectrometry J. Anal. At. Spectrom. 1993 8 571 575
    • (1993) J. Anal. At. Spectrom. , vol.8 , pp. 571-575
    • Story, W.C.1    Caruso, J.A.2
  • 10
    • 0000133821 scopus 로고
    • Application of a microwave-induced plasma atomic emission detector for quantification of halogenated compounds by gas chromatography
    • N. Kovacic T. L. Ramus Application of a microwave-induced plasma atomic emission detector for quantification of halogenated compounds by gas chromatography J. Anal. At. Spectrom. 1992 7 999 1005
    • (1992) J. Anal. At. Spectrom. , vol.7 , pp. 999-1005
    • Kovacic, N.1    Ramus, T.L.2
  • 11
    • 0032530023 scopus 로고    scopus 로고
    • Determination of halogenated hydrocarbons by helium microwave plasma torch time-of-flight mass spectrometry coupled to gas chromatography
    • B. W. Pack J. A. C. Broekaert J. P. Guzowski J. Poehlman G. M. Hieftje Determination of halogenated hydrocarbons by helium microwave plasma torch time-of-flight mass spectrometry coupled to gas chromatography Anal. Chem. 1998 70 3957 3963
    • (1998) Anal. Chem. , vol.70 , pp. 3957-3963
    • Pack, B.W.1    Broekaert, J.A.C.2    Guzowski, J.P.3    Poehlman, J.4    Hieftje, G.M.5
  • 12
    • 0033874239 scopus 로고    scopus 로고
    • Use of a hollow cathode glow discharge (HCGD) as an atomic emission spectrometric element specific detector for chlorine and bromine in gas chromatography
    • DOI 10.1039/a904031e
    • C. Schepers J. A. C. Broekaert The use of a hollow cathode glow discharge (HCGD) as an atomic emission spectrometric element specific detector for chlorine and bromine in gas chromatography J. Anal. At. Spectrom. 2000 15 61 65 (Pubitemid 30542399)
    • (2000) Journal of analytical atomic spectrometry , vol.15 , Issue.1 , pp. 61-65
    • Schepers, C.1    Broekaert, J.A.C.2
  • 13
    • 0032181370 scopus 로고    scopus 로고
    • Studies of a helium-operated gas-sampling Grimm-type glow discharge for the atomic emission spectrometric determination of chlorine in halogenated hydrocarbon vapors
    • J. A. C. Broekaert T. K. Starn L. J. Wright G. M. Hieftje Studies of a helium-operated gas-sampling Grimm-type glow discharge for the atomic emission spectrometric determination of chlorine in halogenated hydrocarbon vapors Spectrochim. Acta, Part B 1998 53 1723 1735
    • (1998) Spectrochim. Acta, Part B , vol.53 , pp. 1723-1735
    • Broekaert, J.A.C.1    Starn, T.K.2    Wright, L.J.3    Hieftje, G.M.4
  • 14
    • 0006535116 scopus 로고    scopus 로고
    • Fundamental study and development of oscillating plasma glow discharge GC detectors
    • D. Y. Maeng S. Y. You B. C. Cha H. Kim H. J. Kim Fundamental study and development of oscillating plasma glow discharge GC detectors Microchem. J. 1997 55 88 98 (Pubitemid 127401797)
    • (1997) Microchemical Journal , vol.55 , Issue.1 , pp. 88-98
    • Maeng, D.Y.1    You, S.Y.2    Cha, B.C.3    Kim, H.4    Kim, H.J.5
  • 18
    • 3242807458 scopus 로고    scopus 로고
    • Microplasmas for chemical analysis: Analytical tools or research toys?
    • V. Karanassios Microplasmas for chemical analysis: analytical tools or research toys? Spectrochim. Acta, Part B 2004 59 909 928
    • (2004) Spectrochim. Acta, Part B , vol.59 , pp. 909-928
    • Karanassios, V.1
  • 19
    • 0033704260 scopus 로고    scopus 로고
    • A low-power 2.45 GHz microwave induced helium plasma source at atmospheric pressure based on microstrip technology
    • A. Bilgic E. Voges U. Engel J. A. C. Broekaert A low-power 2.45 GHz microwave induced helium plasma source at atmospheric pressure based on microstrip technology J. Anal. At. Spectrom. 2000 15 579 580
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 579-580
    • Bilgic, A.1    Voges, E.2    Engel, U.3    Broekaert, J.A.C.4
  • 21
    • 0033970862 scopus 로고    scopus 로고
    • A microwave-induced plasma based on microstrip technology and its use for the atomic emission spectrometric determination of mercury with the aid of the cold-vapor technique
    • DOI 10.1021/ac9906476
    • U. Engel A. M. Bilgic O. Haase E. Voges J. A. C. Broekaert A microwave-induced plasma based on microstrip technology and its use for the atomic emission spectrometric determination of mercury with the aid of the cold-vapor technique Anal. Chem. 2000 72 193 197 (Pubitemid 30027756)
    • (2000) Analytical Chemistry , vol.72 , Issue.1 , pp. 193-197
    • Engel, U.1    Bilgic, A.M.2    Haase, O.3    Voges, E.4    Broekaert, J.A.C.5
  • 22
    • 34547455224 scopus 로고    scopus 로고
    • Evaluation and application of argon and helium microstrip plasma for the determination of mercury by the cold vapor technique and optical emission spectrometry
    • DOI 10.1007/s00216-007-1176-4
    • I. J. Zapata P. Pohl N. H. Bings J. A. C. Broekaert Evaluation and application of argon and helium microstrip plasma for the determination of mercury by the cold vapor technique and optical emission spectrometry Anal. Bioanal. Chem. 2007 388 1615 1623 (Pubitemid 47173079)
    • (2007) Analytical and Bioanalytical Chemistry , vol.388 , Issue.8 , pp. 1615-1623
    • Jimenez Zapata, I.1    Pohl, P.2    Bings, N.H.3    Broekaert, J.A.C.4
  • 23
    • 34250850693 scopus 로고    scopus 로고
    • Optical emission spectrometric determination of arsenic and antimony by continuous flow chemical hydride generation and a miniaturized microwave microstrip argon plasma operated inside a capillary channel in a sapphire wafer
    • DOI 10.1016/j.sab.2007.04.007, PII S0584854707001231
    • P. Pohl I. J. Zapata N. H. Bings E. Voges J. A. C. Broekaert Optical emission spectrometric determination of arsenic and antimony by continuous flow chemical hydride generation and a miniaturized microwave microstrip argon plasma operated inside a capillary channel in a sapphire wafer Spectrochim. Acta, Part B 2007 62 444 453 (Pubitemid 46990680)
    • (2007) Spectrochimica Acta - Part B Atomic Spectroscopy , vol.62 , Issue.5 , pp. 444-453
    • Pohl, P.1    Zapata, I.J.2    Bings, N.H.3    Voges, E.4    Broekaert, J.A.C.5
  • 24
    • 39149090350 scopus 로고    scopus 로고
    • Characterization of a microwave microstrip helium plasma with gas-phase sample introduction for the optical emission spectrometric determination of bromine, chlorine, sulfur and carbon using a miniaturized optical fiber spectrometer
    • P. Pohl I. J. Zapata M. A. Amberger N. H. Bings J. A. C. Broekaert Characterization of a microwave microstrip helium plasma with gas-phase sample introduction for the optical emission spectrometric determination of bromine, chlorine, sulfur and carbon using a miniaturized optical fiber spectrometer Spectrochim. Acta, Part B 2008 63 415 421
    • (2008) Spectrochim. Acta, Part B , vol.63 , pp. 415-421
    • Pohl, P.1    Zapata, I.J.2    Amberger, M.A.3    Bings, N.H.4    Broekaert, J.A.C.5
  • 26
    • 0002025002 scopus 로고
    • Die Berechnung der Nachweisempfindlichkeit
    • H. Kaiser Die Berechnung der Nachweisempfindlichkeit Spectrochim. Acta 1947 3 40 67
    • (1947) Spectrochim. Acta , vol.3 , pp. 40-67
    • Kaiser, H.1
  • 30
    • 0027553005 scopus 로고
    • Analytical characteristics of a helium/hydrogen capacitively coupled microwave plasma
    • W. R. L. Masamba J. D. Winefordner Analytical characteristics of a helium/hydrogen capacitively coupled microwave plasma Spectrochim. Acta, Part B 1993 48 521 529
    • (1993) Spectrochim. Acta, Part B , vol.48 , pp. 521-529
    • Masamba, W.R.L.1    Winefordner, J.D.2
  • 31
    • 0037474863 scopus 로고    scopus 로고
    • Spectroscopic characterization of low power argon microwave-induced plasma with gaseous species produced from ethanol-water solutions in continuous hydride generation process
    • M. Wlodarczyk W. Zyrnicki Spectroscopic characterization of low power argon microwave-induced plasma with gaseous species produced from ethanol-water solutions in continuous hydride generation process Spectrochim. Acta, Part B 2003 58 511 522
    • (2003) Spectrochim. Acta, Part B , vol.58 , pp. 511-522
    • Wlodarczyk, M.1    Zyrnicki, W.2
  • 32
    • 34250466995 scopus 로고
    • Internal standard method calculations
    • D. E. Willis Internal standard method calculations Chromatographia 1972 5 42 43
    • (1972) Chromatographia , vol.5 , pp. 42-43
    • Willis, D.E.1
  • 34
    • 0030616536 scopus 로고    scopus 로고
    • Gas chromatography microwave-induced plasma mass spectrometry (GC-MIP-MS): A multi-element analytical tool for organic geochemistry
    • P. Read H. Beere L. Ebdon M. Leizers M. Hetheridge S. Rowland Gas chromatography microwave-induced plasma mass spectrometry (GC-MIP-MS): a multi-element analytical tool for organic geochemistry Org. Geochem. 1997 26 11 17
    • (1997) Org. Geochem. , vol.26 , pp. 11-17
    • Read, P.1    Beere, H.2    Ebdon, L.3    Leizers, M.4    Hetheridge, M.5    Rowland, S.6
  • 35
    • 4243300460 scopus 로고
    • Optimization of the microwave-induced plasma as an element-selective detector for non-metals
    • J. P. J. van Dalen P. A. de Lezenne Coulander L. de Galan Optimization of the microwave-induced plasma as an element-selective detector for non-metals Anal. Chim. Acta 1977 94 1 19
    • (1977) Anal. Chim. Acta , vol.94 , pp. 1-19
    • Van Dalen, J.P.J.1    De Lezenne Coulander, P.A.2    De Galan, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.