메뉴 건너뛰기




Volumn 41, Issue 8, 2010, Pages 990-996

3D histomorphometric quantification of trabecular bones by computed microtomography using synchrotron radiation

Author keywords

Bone microstructure; Histomorphometry; Image processing; Synchrotron radiation computed microtomography

Indexed keywords

2-D SLICE; 3-D IMAGE; BEAM LINES; BONE ARCHITECTURE; BONE DISEASE; BONE FRAGILITY; BONE HISTOMORPHOMETRY; BONE MICROARCHITECTURE; BONE MICROSTRUCTURE; BONE STRUCTURE; BONE VOLUME FRACTION; COMPUTED MICROTOMOGRAPHY; HISTOMORPHOMETRY; MEDICAL PHYSICS; NONINVASIVE TECHNIQUE; QUANTITATIVE EVALUATION; SYNCHROTRON RADIATION FACILITY; TRABECULAR BONES; X-RAY COMPUTED MICROTOMOGRAPHY;

EID: 79959953500     PISSN: 09684328     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.micron.2010.06.013     Document Type: Article
Times cited : (27)

References (37)
  • 2
    • 34250025099 scopus 로고    scopus 로고
    • Transmenopausal changes in the trabecular bone structure
    • Akhter M.P., Lappe J.M., Davies K.M., Recker R.R. Transmenopausal changes in the trabecular bone structure. Bone 2007, 41:111-116.
    • (2007) Bone , vol.41 , pp. 111-116
    • Akhter, M.P.1    Lappe, J.M.2    Davies, K.M.3    Recker, R.R.4
  • 4
    • 0035991176 scopus 로고    scopus 로고
    • Risedronate preserves trabecular architecture and increases bone strength in vertebra of ovariectomized minipigs as measured by three-dimensional microcomputed tomography
    • Borah B., Dufresne T.E., Chmielewski P.A., Gross G.J., Prenger M.C., Phipps R.J. Risedronate preserves trabecular architecture and increases bone strength in vertebra of ovariectomized minipigs as measured by three-dimensional microcomputed tomography. J. Bone Miner. Res. 2002, 17(7):1139-1147.
    • (2002) J. Bone Miner. Res. , vol.17 , Issue.7 , pp. 1139-1147
    • Borah, B.1    Dufresne, T.E.2    Chmielewski, P.A.3    Gross, G.J.4    Prenger, M.C.5    Phipps, R.J.6
  • 6
    • 33748288353 scopus 로고    scopus 로고
    • Comparison of synchrotron radiation and conventional X-ray microcomputed tomography for assessing trabecular bone microarchitecture of human femoral heads
    • Chappard C., Basillais A., Benhamou L., Bonassie A., Brunet-Imbault B., Bonnet N., Peyrin F. Comparison of synchrotron radiation and conventional X-ray microcomputed tomography for assessing trabecular bone microarchitecture of human femoral heads. Med. Phys. 2006, 33(9):3568-3577.
    • (2006) Med. Phys. , vol.33 , Issue.9 , pp. 3568-3577
    • Chappard, C.1    Basillais, A.2    Benhamou, L.3    Bonassie, A.4    Brunet-Imbault, B.5    Bonnet, N.6    Peyrin, F.7
  • 9
    • 0033976971 scopus 로고    scopus 로고
    • The contribution of trabecular architecture to cancellous bone quality
    • Dempster D.W. The contribution of trabecular architecture to cancellous bone quality. J. Bone Miner. Res. 2000, 15:20-23.
    • (2000) J. Bone Miner. Res. , vol.15 , pp. 20-23
    • Dempster, D.W.1
  • 11
    • 0033956461 scopus 로고    scopus 로고
    • Quantification of age-related changes in the structure model type and trabecular thickness of human tibial cancellous bone
    • Ding M., Hvid I. Quantification of age-related changes in the structure model type and trabecular thickness of human tibial cancellous bone. Bone 2000, 26(3):291-295.
    • (2000) Bone , vol.26 , Issue.3 , pp. 291-295
    • Ding, M.1    Hvid, I.2
  • 12
    • 0043030028 scopus 로고    scopus 로고
    • Changes in the three-dimensional microstructure of human tibial cancellous bone in early osteoarthritis
    • Ding M., Odgaard A., Hvid I. Changes in the three-dimensional microstructure of human tibial cancellous bone in early osteoarthritis. The Journal of Bone and Joint Surgery 2003, 85-B(6):906-912.
    • (2003) The Journal of Bone and Joint Surgery , Issue.6 , pp. 906-912
    • Ding, M.1    Odgaard, A.2    Hvid, I.3
  • 13
    • 0024589979 scopus 로고
    • The direct examination of three-dimensional bone architecture in vitro by computed-tomography
    • Feldkamp L.A., Goldstein S.A., Parfitt A.M., Jesion G., Kleerekoper M. The direct examination of three-dimensional bone architecture in vitro by computed-tomography. J. Bone Miner. Res. 1989, 4(1):3-11.
    • (1989) J. Bone Miner. Res. , vol.4 , Issue.1 , pp. 3-11
    • Feldkamp, L.A.1    Goldstein, S.A.2    Parfitt, A.M.3    Jesion, G.4    Kleerekoper, M.5
  • 15
    • 0033047422 scopus 로고    scopus 로고
    • Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus
    • Hildebrand T., Laib A., Müller R., Dequeker J., Rüegsegger P. Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus. J. Bone Miner. Res. 1999, 14(7):1167-1174.
    • (1999) J. Bone Miner. Res. , vol.14 , Issue.7 , pp. 1167-1174
    • Hildebrand, T.1    Laib, A.2    Müller, R.3    Dequeker, J.4    Rüegsegger, P.5
  • 16
    • 0036208844 scopus 로고    scopus 로고
    • Differences of three-dimensional trabecular microstructure in osteopenic rat models caused by ovariectomy and neurectomy
    • Ito M., Nishida A., Nakamura T., Uetani M., Hayashi K. Differences of three-dimensional trabecular microstructure in osteopenic rat models caused by ovariectomy and neurectomy. Bone 2002, 30(4):594-598.
    • (2002) Bone , vol.30 , Issue.4 , pp. 594-598
    • Ito, M.1    Nishida, A.2    Nakamura, T.3    Uetani, M.4    Hayashi, K.5
  • 17
    • 0028502932 scopus 로고
    • Predicting the compressive mechanical behavior of bone
    • Keller T.S. Predicting the compressive mechanical behavior of bone. J. Biomech. 1994, 27:1159-1168.
    • (1994) J. Biomech. , vol.27 , pp. 1159-1168
    • Keller, T.S.1
  • 18
    • 0344141607 scopus 로고    scopus 로고
    • Comparison of structure extraction methods for in vivo trabecular bone measurements
    • Laib A., Rüegsegger P. Comparison of structure extraction methods for in vivo trabecular bone measurements. Computerized Medical Imaging and Graphics 1999, 23:69-74.
    • (1999) Computerized Medical Imaging and Graphics , vol.23 , pp. 69-74
    • Laib, A.1    Rüegsegger, P.2
  • 20
    • 17744400295 scopus 로고    scopus 로고
    • Accuracy of 3D microscopy for trabecular bone assessment: a comparative study on calcaneus samples using 3D synchrotron radiation microtomography
    • Last D., Peyrin F., Guillot G. Accuracy of 3D microscopy for trabecular bone assessment: a comparative study on calcaneus samples using 3D synchrotron radiation microtomography. MAGMA 2005, 18:26-34.
    • (2005) MAGMA , vol.18 , pp. 26-34
    • Last, D.1    Peyrin, F.2    Guillot, G.3
  • 21
    • 0345015502 scopus 로고    scopus 로고
    • Excised bone structures in mice: imaging at three-dimensional synchrotron radiation micro-CT
    • Marti{dotless}n-Badosa E., Amblard D., Nuzzo S., Elmoutaouakkil A., Vico L., Peyrin F. Excised bone structures in mice: imaging at three-dimensional synchrotron radiation micro-CT. Radiology 2003, 229:921-928.
    • (2003) Radiology , vol.229 , pp. 921-928
    • Martin-Badosa, E.1    Amblard, D.2    Nuzzo, S.3    Elmoutaouakkil, A.4    Vico, L.5    Peyrin, F.6
  • 22
    • 0345596449 scopus 로고    scopus 로고
    • Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography
    • Müller R., Van Campenhout H., Van Damme B., Van Der Perre G., Dequeker J., Hildebrand T., Rüegsegger P. Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography. Bone 1998, 23:59-66.
    • (1998) Bone , vol.23 , pp. 59-66
    • Müller, R.1    Van Campenhout, H.2    Van Damme, B.3    Van Der Perre, G.4    Dequeker, J.5    Hildebrand, T.6    Rüegsegger, P.7
  • 23
    • 0035992618 scopus 로고    scopus 로고
    • Synchrotron radiation microtomography allows the analysis of three-dimensional microarchitecture and degree of mineralization of human iliac crest biopsy specimens: effects of etidronate treatment
    • Nuzzo S., Lafage-Proust M.H., Martin-Badosa E., Boivin G., Thomas T., Alexandre C., Peyrin F. Synchrotron radiation microtomography allows the analysis of three-dimensional microarchitecture and degree of mineralization of human iliac crest biopsy specimens: effects of etidronate treatment. J. Bone Miner. Res. 2002, 17:1372-1382.
    • (2002) J. Bone Miner. Res. , vol.17 , pp. 1372-1382
    • Nuzzo, S.1    Lafage-Proust, M.H.2    Martin-Badosa, E.3    Boivin, G.4    Thomas, T.5    Alexandre, C.6    Peyrin, F.7
  • 24
    • 0036851639 scopus 로고    scopus 로고
    • Quantification of the degree of mineralization of bone in three dimensions using synchrotron radiation microtomography
    • Nuzzo S., Peyrin F., Cloetens P., Baruchel J., Boivin G. Quantification of the degree of mineralization of bone in three dimensions using synchrotron radiation microtomography. Med. Phys. 2002, 29:2672-2681.
    • (2002) Med. Phys. , vol.29 , pp. 2672-2681
    • Nuzzo, S.1    Peyrin, F.2    Cloetens, P.3    Baruchel, J.4    Boivin, G.5
  • 26
    • 3342943462 scopus 로고    scopus 로고
    • 3D histomorphometric quantification from 3D computed tomography
    • Oliveira L.F., Lopes R.T. 3D histomorphometric quantification from 3D computed tomography. Nucl. Instrum. Meth. A 2004, 525:406-411.
    • (2004) Nucl. Instrum. Meth. A , vol.525 , pp. 406-411
    • Oliveira, L.F.1    Lopes, R.T.2
  • 29
    • 33646149773 scopus 로고    scopus 로고
    • Trabecular bone structure of the calcaneus: comparison of MR imaging at 3.0 and 1.5T with micro-CT as the standard of reference
    • Phan C.M., Matsuura M., Bauer J.S., Dunn T.C., Newitt D., Lochmueller E.M., Eckstein F., Majumdar S., Link T.M. Trabecular bone structure of the calcaneus: comparison of MR imaging at 3.0 and 1.5T with micro-CT as the standard of reference. Radiology 2006, 239(2):488-496.
    • (2006) Radiology , vol.239 , Issue.2 , pp. 488-496
    • Phan, C.M.1    Matsuura, M.2    Bauer, J.S.3    Dunn, T.C.4    Newitt, D.5    Lochmueller, E.M.6    Eckstein, F.7    Majumdar, S.8    Link, T.M.9
  • 30
    • 0023868463 scopus 로고
    • On the dependence of the elasticity and strength of cancellous bone on apparent density
    • Rice J.C., Cowin S.C., Bowman J.A. On the dependence of the elasticity and strength of cancellous bone on apparent density. J. Biomech. 1988, 21:155-168.
    • (1988) J. Biomech. , vol.21 , pp. 155-168
    • Rice, J.C.1    Cowin, S.C.2    Bowman, J.A.3
  • 32
  • 33
    • 3242665363 scopus 로고    scopus 로고
    • Analysis of three-dimensional microarchitecture and degree of mineralization in bone metastases from prostate cancer using synchrotron microcomputed tomography
    • Sone T., Tamada T., Jo Y., Miyoshi H., Fukunaga M. Analysis of three-dimensional microarchitecture and degree of mineralization in bone metastases from prostate cancer using synchrotron microcomputed tomography. Bone 2004, 35(2):432-438.
    • (2004) Bone , vol.35 , Issue.2 , pp. 432-438
    • Sone, T.1    Tamada, T.2    Jo, Y.3    Miyoshi, H.4    Fukunaga, M.5
  • 34
    • 61849108749 scopus 로고    scopus 로고
    • Quantification of bone tissue regeneration employing β-tricalcium phosphate by three-dimensional non-invasive synchrotron micro-tomography-a comparative examination with histomorphometry
    • Stiller M., Rack A., Zabler S., Goebbels J., Dalügge O., Jonscher S., Knabe C. Quantification of bone tissue regeneration employing β-tricalcium phosphate by three-dimensional non-invasive synchrotron micro-tomography-a comparative examination with histomorphometry. Bone 2009, 44(4):619-628.
    • (2009) Bone , vol.44 , Issue.4 , pp. 619-628
    • Stiller, M.1    Rack, A.2    Zabler, S.3    Goebbels, J.4    Dalügge, O.5    Jonscher, S.6    Knabe, C.7
  • 35
    • 33744917253 scopus 로고    scopus 로고
    • Time-lapsed investigation of three-dimensional failure and damage accumulation in trabecular bone using synchrotron light
    • Thurner P.J., Wyss P., Voide R., Stauber M., Stampanoni M., Sennhauser U., Müller R. Time-lapsed investigation of three-dimensional failure and damage accumulation in trabecular bone using synchrotron light. Bone 2006, 39:289-299.
    • (2006) Bone , vol.39 , pp. 289-299
    • Thurner, P.J.1    Wyss, P.2    Voide, R.3    Stauber, M.4    Stampanoni, M.5    Sennhauser, U.6    Müller, R.7
  • 36
    • 33847624166 scopus 로고    scopus 로고
    • Nondestructive micro-computed tomography for biological imaging and quantification of scaffold-bone interaction in vivo
    • Van Lenthe G.H., Hagenmuller H., Bohner M., Hollister S.J., Meinel L., Muller R. Nondestructive micro-computed tomography for biological imaging and quantification of scaffold-bone interaction in vivo. Biomaterials 2007, 28:2479-2490.
    • (2007) Biomaterials , vol.28 , pp. 2479-2490
    • Van Lenthe, G.H.1    Hagenmuller, H.2    Bohner, M.3    Hollister, S.J.4    Meinel, L.5    Muller, R.6
  • 37
    • 0032995520 scopus 로고    scopus 로고
    • The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
    • Ulrich D., Rietbergen B.V., Laib A., Rüegsegger P. The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone. Bone 1999, 25(1):55-60.
    • (1999) Bone , vol.25 , Issue.1 , pp. 55-60
    • Ulrich, D.1    Rietbergen, B.V.2    Laib, A.3    Rüegsegger, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.