메뉴 건너뛰기




Volumn 74, Issue 1, 2011, Pages 58-64

A prospective, single-blind, randomized, controlled trial of EUS-guided FNA with and without a stylet

Author keywords

[No Author keywords available]

Indexed keywords

ADRENAL TUMOR; ADULT; ARTICLE; ASPIRATION BIOPSY; CELL COUNT; CELLULARITY; CONTAMINATION; CONTROLLED STUDY; CYTOLOGY; CYTOPATHOLOGY; DIAGNOSTIC VALUE; ENDOSCOPIC ECHOGRAPHY; FEMALE; HUMAN; HUMAN CELL; HUMAN TISSUE; LIVER DISEASE; LYMPH NODE; MAJOR CLINICAL STUDY; MALE; MULTICENTER STUDY; NEEDLE; NEEDLE STYLET; OUTCOME ASSESSMENT; PANCREAS TUMOR; PATIENT REFERRAL; PRIORITY JOURNAL; PROSPECTIVE STUDY; QUALITY CONTROL; RANDOMIZED CONTROLLED TRIAL; SINGLE BLIND PROCEDURE; SOLID TUMOR; TERTIARY HEALTH CARE;

EID: 79959712501     PISSN: 00165107     EISSN: 10976779     Source Type: Journal    
DOI: 10.1016/j.gie.2011.02.015     Document Type: Article
Times cited : (81)

References (16)
  • 1
    • 3242743595 scopus 로고    scopus 로고
    • EUS-guided FNA
    • DOI 10.1016/S0016-5107(04)01529-9, PII S0016510704015299
    • R.A. Erickson EUS-guided FNA Gastrointest Endosc 60 2004 267 279 (Pubitemid 38980687)
    • (2004) Gastrointestinal Endoscopy , vol.60 , Issue.2 , pp. 267-279
    • Erickson, R.A.1
  • 2
    • 35548967452 scopus 로고    scopus 로고
    • Endoscopic Ultrasound-Guided Fine-Needle Aspiration: Sampling, Pitfalls, and Quality Management
    • DOI 10.1016/j.cgh.2007.09.011, PII S154235650700897X
    • P. Kulesza, and I.A. Eltoum Endoscopic ultrasound-guided fine-needle aspiration: sampling, pitfalls, and quality management Clin Gastroenterol Hepatol 5 2007 1248 1254 (Pubitemid 350019066)
    • (2007) Clinical Gastroenterology and Hepatology , vol.5 , Issue.11 , pp. 1248-1254
    • Kulesza, P.1    Eltoum, I.A.2
  • 4
    • 0345742766 scopus 로고    scopus 로고
    • The learning curve for EUS-guided FNA of pancreatic cancer
    • DOI 10.1016/S0016-5107(03)02028-5, PII S0016510703020285
    • H. Mertz, and S. Gautam The learning curve for EUS-guided FNA of pancreatic cancer Gastrointest Endosc 59 2004 33 37 (Pubitemid 38095504)
    • (2004) Gastrointestinal Endoscopy , vol.59 , Issue.1 , pp. 33-37
    • Mertz, H.1    Gautam, S.2
  • 5
    • 0038310881 scopus 로고    scopus 로고
    • Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration
    • DOI 10.1111/j.1572-0241.2003.07472.x
    • J.B. Klapman, R. Logrono, and C.E. Dye Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration Am J Gastroenterol 98 2003 1289 1294 (Pubitemid 36741524)
    • (2003) American Journal of Gastroenterology , vol.98 , Issue.6 , pp. 1289-1294
    • Klapman, J.B.1    Logrono, R.2    Dye, C.E.3    Waxman, I.4
  • 6
    • 70749145834 scopus 로고    scopus 로고
    • EUS-guided FNA of solid pancreatic masses: A prospective, randomized trial comparing 22-gauge and 25-gauge needles
    • U.D. Siddiqui, F. Rossi, and L.S. Rosenthal EUS-guided FNA of solid pancreatic masses: a prospective, randomized trial comparing 22-gauge and 25-gauge needles Gastrointest Endosc 70 2009 1093 1097
    • (2009) Gastrointest Endosc , vol.70 , pp. 1093-1097
    • Siddiqui, U.D.1    Rossi, F.2    Rosenthal, L.S.3
  • 7
    • 67849097685 scopus 로고    scopus 로고
    • Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: A multicenter experience
    • T.E. Yusuf, S. Ho, and D.A. Pavey Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience Endoscopy 41 2009 445 448
    • (2009) Endoscopy , vol.41 , pp. 445-448
    • Yusuf, T.E.1    Ho, S.2    Pavey, D.A.3
  • 8
    • 77955413926 scopus 로고    scopus 로고
    • The prospective randomized, controlled trial of endoscopic ultrasound-guided fine needle aspiration using 22G and 19G aspiration needles for solid pancreatic and peripancreatic masses
    • T.J. Song, J.H. Kim, and S.S. Lee The prospective randomized, controlled trial of endoscopic ultrasound-guided fine needle aspiration using 22G and 19G aspiration needles for solid pancreatic and peripancreatic masses Am J Gastroenterol 105 2010 1739 1745
    • (2010) Am J Gastroenterol , vol.105 , pp. 1739-1745
    • Song, T.J.1    Kim, J.H.2    Lee, S.S.3
  • 9
    • 67049142370 scopus 로고    scopus 로고
    • Randomized controlled trial of endoscopic ultrasound-guided fine-needle sampling with or without suction for better cytological diagnosis
    • R. Puri, P. Vilmann, and A. Saftoiu Randomized controlled trial of endoscopic ultrasound-guided fine-needle sampling with or without suction for better cytological diagnosis Scand J Gastroenterol 44 2009 499 504
    • (2009) Scand J Gastroenterol , vol.44 , pp. 499-504
    • Puri, R.1    Vilmann, P.2    Saftoiu, A.3
  • 11
    • 78349268002 scopus 로고    scopus 로고
    • A prospective comparison of endoscopic ultrasound-guided fine needle aspiration results obtained in the same lesion, with and without the needle stylet
    • A.V. Sahai, S.C. Paquin, and G. Gariepy A prospective comparison of endoscopic ultrasound-guided fine needle aspiration results obtained in the same lesion, with and without the needle stylet Endoscopy 42 2010 900 903
    • (2010) Endoscopy , vol.42 , pp. 900-903
    • Sahai, A.V.1    Paquin, S.C.2    Gariepy, G.3
  • 12
    • 78649328491 scopus 로고    scopus 로고
    • Is the use of stylet during endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) worth the effort?: A comparative study of EUS-FNA with and without a stylet [abstract]
    • S.B. Wani, N. Gupta, and S. Gaddam Is the use of stylet during endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) worth the effort? A comparative study of EUS-FNA with and without a stylet [abstract] Gastrointest Endosc 71 2010 AB286
    • (2010) Gastrointest Endosc , vol.71 , pp. 286
    • Wani, S.B.1    Gupta, N.2    Gaddam, S.3
  • 13
    • 77953395873 scopus 로고    scopus 로고
    • CONSORT 2010 statement: Updated guidelines for reporting parallel group randomized trials
    • K.F. Schulz, D.G. Altman, and D. Moher CONSORT 2010 statement: updated guidelines for reporting parallel group randomized trials Ann Intern Med 152 2010 726 732
    • (2010) Ann Intern Med , vol.152 , pp. 726-732
    • Schulz, K.F.1    Altman, D.G.2    Moher, D.3
  • 15
    • 79551481762 scopus 로고    scopus 로고
    • The yield of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is not affected by leaving out the stylet [abstract]
    • N. Devicente, R. Hawes, and B. Hoffman The yield of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is not affected by leaving out the stylet [abstract] Gastrointest Endosc 69 2009 AB335
    • (2009) Gastrointest Endosc , vol.69 , pp. 335
    • Devicente, N.1    Hawes, R.2    Hoffman, B.3
  • 16
    • 78649332149 scopus 로고    scopus 로고
    • Stylet use does not affect adequacy of specimen of pancreatic EUS FNA: A prospective, single blinded, randomized, control trial [abstract]
    • M.W. Chin, A. Coss, and M. Mcloughlin Stylet use does not affect adequacy of specimen of pancreatic EUS FNA: a prospective, single blinded, randomized, control trial [abstract] Gastrointest Endosc 71 2010 AB285
    • (2010) Gastrointest Endosc , vol.71 , pp. 285
    • Chin, M.W.1    Coss, A.2    McLoughlin, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.