-
1
-
-
3242743595
-
EUS-guided FNA
-
DOI 10.1016/S0016-5107(04)01529-9, PII S0016510704015299
-
R.A. Erickson EUS-guided FNA Gastrointest Endosc 60 2004 267 279 (Pubitemid 38980687)
-
(2004)
Gastrointestinal Endoscopy
, vol.60
, Issue.2
, pp. 267-279
-
-
Erickson, R.A.1
-
2
-
-
35548967452
-
Endoscopic Ultrasound-Guided Fine-Needle Aspiration: Sampling, Pitfalls, and Quality Management
-
DOI 10.1016/j.cgh.2007.09.011, PII S154235650700897X
-
P. Kulesza, and I.A. Eltoum Endoscopic ultrasound-guided fine-needle aspiration: sampling, pitfalls, and quality management Clin Gastroenterol Hepatol 5 2007 1248 1254 (Pubitemid 350019066)
-
(2007)
Clinical Gastroenterology and Hepatology
, vol.5
, Issue.11
, pp. 1248-1254
-
-
Kulesza, P.1
Eltoum, I.A.2
-
3
-
-
32044462317
-
Review of endoscopic ultrasound-guided fine-needle aspiration cytology
-
DOI 10.1002/dc.20300
-
R.H. Bardales, E.B. Stelow, and S. Mallery Review of endoscopic ultrasound-guided fine-needle aspiration cytology Diagn Cytopathol 34 2006 140 175 (Pubitemid 43201569)
-
(2006)
Diagnostic Cytopathology
, vol.34
, Issue.2
, pp. 140-175
-
-
Bardales, R.H.1
Stelow, E.B.2
Mallery, S.3
Lai, R.4
Stanley, M.W.5
-
4
-
-
0345742766
-
The learning curve for EUS-guided FNA of pancreatic cancer
-
DOI 10.1016/S0016-5107(03)02028-5, PII S0016510703020285
-
H. Mertz, and S. Gautam The learning curve for EUS-guided FNA of pancreatic cancer Gastrointest Endosc 59 2004 33 37 (Pubitemid 38095504)
-
(2004)
Gastrointestinal Endoscopy
, vol.59
, Issue.1
, pp. 33-37
-
-
Mertz, H.1
Gautam, S.2
-
5
-
-
0038310881
-
Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration
-
DOI 10.1111/j.1572-0241.2003.07472.x
-
J.B. Klapman, R. Logrono, and C.E. Dye Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration Am J Gastroenterol 98 2003 1289 1294 (Pubitemid 36741524)
-
(2003)
American Journal of Gastroenterology
, vol.98
, Issue.6
, pp. 1289-1294
-
-
Klapman, J.B.1
Logrono, R.2
Dye, C.E.3
Waxman, I.4
-
6
-
-
70749145834
-
EUS-guided FNA of solid pancreatic masses: A prospective, randomized trial comparing 22-gauge and 25-gauge needles
-
U.D. Siddiqui, F. Rossi, and L.S. Rosenthal EUS-guided FNA of solid pancreatic masses: a prospective, randomized trial comparing 22-gauge and 25-gauge needles Gastrointest Endosc 70 2009 1093 1097
-
(2009)
Gastrointest Endosc
, vol.70
, pp. 1093-1097
-
-
Siddiqui, U.D.1
Rossi, F.2
Rosenthal, L.S.3
-
7
-
-
67849097685
-
Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: A multicenter experience
-
T.E. Yusuf, S. Ho, and D.A. Pavey Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience Endoscopy 41 2009 445 448
-
(2009)
Endoscopy
, vol.41
, pp. 445-448
-
-
Yusuf, T.E.1
Ho, S.2
Pavey, D.A.3
-
8
-
-
77955413926
-
The prospective randomized, controlled trial of endoscopic ultrasound-guided fine needle aspiration using 22G and 19G aspiration needles for solid pancreatic and peripancreatic masses
-
T.J. Song, J.H. Kim, and S.S. Lee The prospective randomized, controlled trial of endoscopic ultrasound-guided fine needle aspiration using 22G and 19G aspiration needles for solid pancreatic and peripancreatic masses Am J Gastroenterol 105 2010 1739 1745
-
(2010)
Am J Gastroenterol
, vol.105
, pp. 1739-1745
-
-
Song, T.J.1
Kim, J.H.2
Lee, S.S.3
-
9
-
-
67049142370
-
Randomized controlled trial of endoscopic ultrasound-guided fine-needle sampling with or without suction for better cytological diagnosis
-
R. Puri, P. Vilmann, and A. Saftoiu Randomized controlled trial of endoscopic ultrasound-guided fine-needle sampling with or without suction for better cytological diagnosis Scand J Gastroenterol 44 2009 499 504
-
(2009)
Scand J Gastroenterol
, vol.44
, pp. 499-504
-
-
Puri, R.1
Vilmann, P.2
Saftoiu, A.3
-
10
-
-
0035486763
-
Randomized controlled trial of EUS-guided fine needle aspiration techniques for the detection of malignant lymphadenopathy
-
DOI 10.1067/mge.2001.117764
-
M.B. Wallace, T. Kennedy, and V. Durkalski Randomized controlled trial of EUS-guided fine needle aspiration techniques for the detection of malignant lymphadenopathy Gastrointest Endosc 54 2001 441 447 (Pubitemid 33661147)
-
(2001)
Gastrointestinal Endoscopy
, vol.54
, Issue.4
, pp. 441-447
-
-
Wallace, M.B.1
Kennedy, T.2
Durkalski, V.3
Eloubeidi, M.A.4
Etamad, R.5
Matsuda, K.6
Lewin, D.7
Van Velse, A.8
Hennesey, W.9
Hawes, R.H.10
Hoffman, B.J.11
-
11
-
-
78349268002
-
A prospective comparison of endoscopic ultrasound-guided fine needle aspiration results obtained in the same lesion, with and without the needle stylet
-
A.V. Sahai, S.C. Paquin, and G. Gariepy A prospective comparison of endoscopic ultrasound-guided fine needle aspiration results obtained in the same lesion, with and without the needle stylet Endoscopy 42 2010 900 903
-
(2010)
Endoscopy
, vol.42
, pp. 900-903
-
-
Sahai, A.V.1
Paquin, S.C.2
Gariepy, G.3
-
12
-
-
78649328491
-
Is the use of stylet during endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) worth the effort?: A comparative study of EUS-FNA with and without a stylet [abstract]
-
S.B. Wani, N. Gupta, and S. Gaddam Is the use of stylet during endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) worth the effort? A comparative study of EUS-FNA with and without a stylet [abstract] Gastrointest Endosc 71 2010 AB286
-
(2010)
Gastrointest Endosc
, vol.71
, pp. 286
-
-
Wani, S.B.1
Gupta, N.2
Gaddam, S.3
-
13
-
-
77953395873
-
CONSORT 2010 statement: Updated guidelines for reporting parallel group randomized trials
-
K.F. Schulz, D.G. Altman, and D. Moher CONSORT 2010 statement: updated guidelines for reporting parallel group randomized trials Ann Intern Med 152 2010 726 732
-
(2010)
Ann Intern Med
, vol.152
, pp. 726-732
-
-
Schulz, K.F.1
Altman, D.G.2
Moher, D.3
-
14
-
-
0037417585
-
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative
-
P.M. Bossuyt, J.B. Reitsma, and D.E. Bruns Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative BMJ 326 2003 41 44 (Pubitemid 36110721)
-
(2003)
British Medical Journal
, vol.326
, Issue.7379
, pp. 41-44
-
-
Bossuyt, P.M.1
Reitsma, J.B.2
Bruns, D.E.3
Gatsonis, C.A.4
Glasziou, P.P.5
Irwig, L.M.6
Lijmer, J.G.7
Moher, D.8
Rennie, D.9
De Vet, H.C.W.10
-
15
-
-
79551481762
-
The yield of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is not affected by leaving out the stylet [abstract]
-
N. Devicente, R. Hawes, and B. Hoffman The yield of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is not affected by leaving out the stylet [abstract] Gastrointest Endosc 69 2009 AB335
-
(2009)
Gastrointest Endosc
, vol.69
, pp. 335
-
-
Devicente, N.1
Hawes, R.2
Hoffman, B.3
-
16
-
-
78649332149
-
Stylet use does not affect adequacy of specimen of pancreatic EUS FNA: A prospective, single blinded, randomized, control trial [abstract]
-
M.W. Chin, A. Coss, and M. Mcloughlin Stylet use does not affect adequacy of specimen of pancreatic EUS FNA: a prospective, single blinded, randomized, control trial [abstract] Gastrointest Endosc 71 2010 AB285
-
(2010)
Gastrointest Endosc
, vol.71
, pp. 285
-
-
Chin, M.W.1
Coss, A.2
McLoughlin, M.3
|