메뉴 건너뛰기




Volumn 30, Issue 7, 2011, Pages 899-908

Variables influencing the accuracy of 2-dimensional and real-time 3-dimensional echocardiography for assessment of small volumes, areas, and distances : An in vitro study using static tissue-mimicking phantoms

Author keywords

3 dimensional echocardiography; Accuracy; Children; Congenital heart disease; Echocardiography; Real time echocardiography

Indexed keywords

DATA ACQUISITION; ERRORS; SYSTEMATIC ERRORS; TISSUE;

EID: 79959601700     PISSN: 02784297     EISSN: None     Source Type: Journal    
DOI: 10.7863/jum.2011.30.7.899     Document Type: Article
Times cited : (13)

References (20)
  • 1
    • 11144250220 scopus 로고    scopus 로고
    • Borderline left ventricle
    • DOI 10.1016/j.ejcts.2004.10.034, PII S101079400400778X
    • Corno AF. Borderline left ventricle. Eur J Cardiothorac Surg 2005; 27:67-73. (Pubitemid 40038530)
    • (2005) European Journal of Cardio-thoracic Surgery , vol.27 , Issue.1 , pp. 67-73
    • Corno, A.F.1
  • 2
    • 13444274525 scopus 로고    scopus 로고
    • Left heart growth, function, and reintervention after balloon aortic valvuloplasty for neonatal aortic stenosis
    • DOI 10.1161/01.CIR.0000153809.88286.2E
    • McElhinney DB, Lock JE, Keane JF, Moran AM, Colan SD. Left heart growth, function, and reintervention after balloon aortic valvuloplasty for neonatal aortic stenosis. Circulation 2005; 111:451-458. (Pubitemid 40204429)
    • (2005) Circulation , vol.111 , Issue.4 , pp. 451-458
    • McElhinney, D.B.1    Lock, J.E.2    Keane, J.F.3    Moran, A.M.4    Colan, S.D.5
  • 3
    • 42649093771 scopus 로고    scopus 로고
    • How accurately reproducibly and efficiently can we measure left ventricular indices using M-mode 2-dimensional and 3-dimensional echocardiography in children?
    • Lu X, Xie M, Tomberlin D, et al. How accurately, reproducibly, and efficiently can we measure left ventricular indices using M-mode, 2-dimensional, and 3-dimensional echocardiography in children? Am Heart J 2008; 155:946-953.
    • (2008) Am Heart J , vol.155 , pp. 946-953
    • Lu, X.1    Xie, M.2    Tomberlin, D.3
  • 5
    • 59849086038 scopus 로고    scopus 로고
    • Real-time 3-dimensional echocardiography: An integral component of the routine echocardiographic examination in adult patients?
    • Mor-Avi V, Sugeng L, Lang RM. Real-time 3-dimensional echocardiography: an integral component of the routine echocardiographic examination in adult patients? Circulation 2009; 119:314-329.
    • (2009) Circulation , vol.119 , pp. 314-329
    • Mor-Avi, V.1    Sugeng, L.2    Lang, R.M.3
  • 6
    • 34247624529 scopus 로고    scopus 로고
    • Variables Influencing the Accuracy of Right Ventricular Volume Assessment by Real-time 3-Dimensional Echocardiography: An In Vitro Validation Study
    • DOI 10.1016/j.echo.2006.10.017, PII S0894731706010704
    • Hoch M, Vasilyev NV, Soriano B, Gauvreau K, Marx GR. Variables influencing the accuracy of right ventricular volume assessment by real-time 3-dimensional echocardiography: an in vitro validation study. J Am Soc Echocardiogr 2007; 20:456-461. (Pubitemid 46678690)
    • (2007) Journal of the American Society of Echocardiography , vol.20 , Issue.5 , pp. 456-461
    • Hoch, M.1    Vasilyev, N.V.2    Soriano, B.3    Gauvreau, K.4    Marx, G.R.5
  • 7
    • 77949347593 scopus 로고    scopus 로고
    • Left ventricular volumetry in healthy children and adolescents: Comparison of two different real-time three-dimensional matrix transducers with cardiovascular magnetic resonance
    • Laser KT, Bunge M, Hauffe P, et al. Left ventricular volumetry in healthy children and adolescents: comparison of two different real-time three-dimensional matrix transducers with cardiovascular magnetic resonance. Eur J Echocardiogr 2010; 11:138-148.
    • (2010) Eur J Echocardiogr , vol.11 , pp. 138-148
    • Laser, K.T.1    Bunge, M.2    Hauffe, P.3
  • 8
    • 41949120031 scopus 로고    scopus 로고
    • Matrix-array 3-dimensional echocardiographic assessment of volumes, mass, and ejection fraction in young pediatric patients with a functional single ventricle: A comparison study with cardiac magnetic resonance
    • DOI 10.1161/CIRCULATIONAHA.107.715854, PII 0000301720080408000011
    • Soriano BD, Hoch M, Ithuralde A, et al. Matrix-array 3-dimensional echocardiographic assessment of volumes, mass, and ejection fraction in young pediatric patients with a functional single ventricle: a comparison study with cardiac magnetic resonance. Circulation2008; 117:1842-1848. (Pubitemid 351507472)
    • (2008) Circulation , vol.117 , Issue.14 , pp. 1842-1848
    • Soriano, B.D.1    Hoch, M.2    Ithuralde, A.3    Geva, T.4    Powell, A.J.5    Kussman, B.D.6    Graham, D.A.7    Tworetzky, W.8    Marx, G.R.9
  • 9
    • 0036788598 scopus 로고    scopus 로고
    • Accuracy of realtime three-dimensional echocardiography for quantifying right ventricular volume: Static and pulsatile flow studies in an anatomic in vitro model
    • Schindera ST, Mehwald PS, Sahn DJ, Kececioglu D. Accuracy of realtime three-dimensional echocardiography for quantifying right ventricular volume: static and pulsatile flow studies in an anatomic in vitro model. J Ultrasound Med 2002; 21:1069-1075.
    • (2002) J Ultrasound Med , vol.21 , pp. 1069-1075
    • Schindera, S.T.1    Mehwald, P.S.2    Sahn, D.J.3    Kececioglu, D.4
  • 10
    • 79951479438 scopus 로고    scopus 로고
    • Volumetry of fetal hearts using 3D real-time matrix echocardiography: In vitro validation experiments and 3D echocardiographic studies in fetuses
    • Herberg U, Lück S, Steinweg B, et al. Volumetry of fetal hearts using 3D real-time matrix echocardiography: in vitro validation experiments and 3D echocardiographic studies in fetuses. Ultraschall Med 2011; 32:46-53.
    • (2011) Ultraschall Med , vol.32 , pp. 46-53
    • Herberg, U.1    Lück, S.2    Steinweg, B.3
  • 11
    • 0031814617 scopus 로고    scopus 로고
    • Real-time B-mode ultrasound quality control test procedures: Report of AAPM Ultrasound Task Group No. 1
    • DOI 10.1118/1.598404
    • Goodsitt MM, Carson PL, Witt S, Hykes DL, Kofler JM Jr. Real-time Bmode ultrasound quality control test procedures: report of AAPM Ultrasound Task Group No. 1. Med Phys 1998; 25:1385-1406. (Pubitemid 28376349)
    • (1998) Medical Physics , vol.25 , Issue.8 , pp. 1385-1406
    • Goodsitt, M.M.1    Carson, P.L.2    Witt, S.3    Hykes, D.L.4    Kofler Jr., J.M.5
  • 13
    • 85027238057 scopus 로고    scopus 로고
    • CIRS. Ultrasound phantoms for 2D & 3D evaluation, Accessed November
    • CIRS. Ultrasound phantoms for 2D & 3D evaluation. CIRS website. http://www.cirsinc.com/pdfs/555.pdf. Accessed November 22, 2010.
    • (2010) CIRS website , vol.22
  • 15
    • 50249182904 scopus 로고    scopus 로고
    • Practical guide for three-dimensional transthoracic echocardiography using a fully sampled matrix array transducer
    • American Society of Echocardiography
    • Yang HS, Bansal RC, Mookadam F, Khandheria BK, Tajik AJ, Chandrasekaran K; American Society of Echocardiography. Practical guide for three-dimensional transthoracic echocardiography using a fully sampled matrix array transducer. J Am Soc Echocardiogr 2008; 21:979-989.
    • (2008) J Am Soc Echocardiogr , vol.21 , pp. 979-989
    • Yang, H.S.1    Bansal, R.C.2    Mookadam, F.3    Khandheria, B.K.4    Tajik, A.J.5    Chandrasekaran, K.6
  • 16
    • 79951491582 scopus 로고    scopus 로고
    • Accuracy of 3D-real-time echocardiography for the assessment of small volumes and distances
    • Herberg U, Brand M, Trier HG, von Hahn R, Bernhardt C, Breuer J. Accuracy of 3D-real-time echocardiography for the assessment of small volumes and distances. Cardiol Young 2008; 18(suppl 1):6-7.
    • (2008) Cardiol Young , vol.18 , Issue.SUPPL. 1 , pp. 6-7
    • Herberg, U.1    Brand, M.2    Trier, H.G.3    Von Hahn, R.4    Bernhardt, C.5    Breuer, J.6
  • 17
    • 33847251987 scopus 로고    scopus 로고
    • 3D echocardiography: A review of the current status and future directions
    • Hung J, Lang R, Flachskampf F, et al. 3D echocardiography: a review of the current status and future directions. J Am Soc Echocardiogr 2007; 20:213-233.
    • (2007) J Am Soc Echocardiogr , vol.20 , pp. 213-233
    • Hung, J.1    Lang, R.2    Flachskampf, F.3
  • 18
    • 79959608903 scopus 로고    scopus 로고
    • How accurate are measurements using commercial 3D ultrasound systems? Studies on quality assurance of 3D echocardiography
    • Herberg U, Brand M, Putzke M, et al. How accurate are measurements using commercial 3D ultrasound systems? Studies on quality assurance of 3D echocardiography. Clin Res Cardiol 2009; 98:605.
    • (2009) Clin Res Cardiol , vol.98 , pp. 605
    • Herberg, U.1    Brand, M.2    Putzke, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.