메뉴 건너뛰기




Volumn 38, Issue 5, 2011, Pages 2412-2418

Influence of dose calculation algorithms on the predicted dose distributions and NTCP values for NSCLC patients

Author keywords

density correction; dose; dose calculation algorithm; NSCLC; NTCP

Indexed keywords

BIOLOGICAL ORGANS; FAST FOURIER TRANSFORMS; HEART; PATIENT MONITORING; PATIENT TREATMENT;

EID: 79959555893     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3575418     Document Type: Article
Times cited : (27)

References (17)
  • 1
    • 0038176478 scopus 로고    scopus 로고
    • Experimental validation tests of fast Fourier transform convolution and multigrid superposition algorithms for dose calculation in low-density media
    • DOI 10.1016/S0167-8140(03)00037-9
    • F. Garca-Vicente, A. Miambres, I. Jerez, I. Modolell, L. Pérez, and J. J. Torres, Experimental validation tests of fast Fourier transform convolution and multigrid superposition algorithms for dose calculation in low-density media., Radiother. Oncol. 67 (2), 239-249 (2003). 10.1016/S0167-8140(03)00037-9 (Pubitemid 36695103)
    • (2003) Radiotherapy and Oncology , vol.67 , Issue.2 , pp. 239-249
    • Garcia-Vicente, F.1    Minambres, A.2    Jerez, I.3    Modolell, I.4    Perez, L.5    Torres, J.J.6
  • 2
    • 0141849098 scopus 로고    scopus 로고
    • Experimental verification of convolution/superposition photon dose calculations for radiotherapy treatment planning
    • DOI 10.1088/0031-9155/48/17/309, PII S0031915503592855
    • M. M. Aspradakis, R. H. Morrison, N. D. Richmond, and A. Steele, Experimental verification of convolution/superposition photon dose calculations for radiotherapy treatment planning., Phys. Med. Biol. 48 (17), 2873-2893 (2003). 10.1088/0031-9155/48/17/309 (Pubitemid 37121465)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.17 , pp. 2873-2893
    • Aspradakis, M.M.1    Morrison, R.H.2    Richmond, N.D.3    Steele, A.4
  • 3
    • 7244223251 scopus 로고    scopus 로고
    • Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium
    • DOI 10.1118/1.1788932
    • P. Carrasco, N. Jornet, M. A. Duch, L. Weber, M. Ginjaume, T. Eudaldo, D. Jurado, A. Ruiz, and M. Ribas, Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium., Med. Phys. 31 (10), 2899-2911 (2004). 10.1118/1.1788932 (Pubitemid 39431019)
    • (2004) Medical Physics , vol.31 , Issue.10 , pp. 2899-2911
    • Carrasco, P.1    Jornet, N.2    Duch, M.A.3    Weber, L.4    Ginjaume, M.5    Eudaldo, T.6    Jurado, D.7    Ruiz, A.8    Ribas, M.9
  • 4
    • 22844452234 scopus 로고    scopus 로고
    • Experimental verification of lung dose with radiochromic film: Comparison with Monte Carlo simulations and commercially available treatment planning systems
    • DOI 10.1088/0031-9155/50/9/009
    • L. Paelinck, N. Reynaert, H. Thierens, W. De Neve, and C. De Wagter, Experimental verification of lung dose with radiochromic film: Comparison with Monte Carlo simulations and commercially available treatment planning systems., Phys. Med. Biol. 50 (9), 2055-2069 (2005). 10.1088/0031-9155/50/9/009 (Pubitemid 41237194)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.9 , pp. 2055-2069
    • Paelinck, L.1    Reynaert, N.2    Thierens, H.3    De Neve, W.4    De Wagter, C.5
  • 5
    • 85024951939 scopus 로고    scopus 로고
    • Comparison of RTP dose distributions in heterogeneous phantoms with the beam Monte Carlo simulation system
    • 10.1120/1.1328616
    • M. Miften, M. Wiesmeyer, A. Kapur, and C. M. Ma, Comparison of RTP dose distributions in heterogeneous phantoms with the beam Monte Carlo simulation system., J. Appl. Clin. Med. Phys. 2 (1), 21-31 (2001). 10.1120/1.1328616
    • (2001) J. Appl. Clin. Med. Phys. , vol.2 , Issue.1 , pp. 21-31
    • Miften, M.1    Wiesmeyer, M.2    Kapur, A.3    Ma, C.M.4
  • 6
    • 15744398473 scopus 로고    scopus 로고
    • Comparison of inhomogeneity correction algorithms in small photon fields
    • DOI 10.1118/1.1861154
    • A. O. Jones and I. J. Das, Comparison of inhomogeneity correction algorithms in small photon fields., Med. Phys. 32 (3), 766-776 (2005). 10.1118/1.1861154 (Pubitemid 40411478)
    • (2005) Medical Physics , vol.32 , Issue.3 , pp. 766-776
    • Jones, A.O.1    Das, I.J.2
  • 7
    • 34247207650 scopus 로고    scopus 로고
    • On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: Comparison with Monte Carlo calculations
    • DOI 10.1088/0031-9155/52/5/011, PII S0031915507288840, 011
    • A. Fogliata, E. Vanetti, D. Albers, C. Brink, A. Clivio, T. Kns, G. Nicolini, and L. Cozzi, On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: Comparison with Monte Carlo calculations., Phys. Med. Biol. 52 (5), 1363-1385 (2007). 10.1088/0031-9155/52/5/011 (Pubitemid 46646393)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.5 , pp. 1363-1385
    • Fogliata, A.1    Vanetti, E.2    Albers, D.3    Brink, C.4    Clivio, A.5    Knoos, T.6    Nicolini, G.7    Cozzi, L.8
  • 8
    • 33846882623 scopus 로고    scopus 로고
    • Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations
    • DOI 10.1088/0031-9155/51/22/005, PII S0031915506236959, 005
    • T. Kns, E. Wieslander, L. Cozzi, C. Brink, A. Fogliata, D. Albers, H. Nystrm, and S. Lassen, Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations., Phys. Med. Biol. 51 (22), 5785-5807 (2006). 10.1088/0031-9155/51/22/005 (Pubitemid 46217668)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.22 , pp. 5785-5807
    • Knoos, T.1    Wieslander, E.2    Cozzi, L.3    Brink, C.4    Fogliata, A.5    Albers, D.6    Nystrom, H.7    Lassen, S.8
  • 9
    • 0022330985 scopus 로고
    • Complication probability as assessed from dose-volume histograms
    • 10.2307/3583506
    • J. T. Lyman, Complication probability as assessed from dose-volume histograms., Radiat. Res., Suppl. 8, S13-S19 (1985). 10.2307/3583506
    • (1985) Radiat. Res., Suppl. , vol.8
    • Lyman, J.T.1
  • 10
    • 0024317128 scopus 로고
    • Calculation of complication probability factors for non-uniform normal tissue irradiation: The effective volume method
    • G. J. Kutcher and C. Burman, Calculation of complication probability factors for non-uniform normal tissue irradiation: The effective volume method., Int. J. Radiat. Oncol., Biol., Phys. 16 (6), 1623-1630 (1989). 10.1016/0360-3016(89)90972-3 (Pubitemid 19154353)
    • (1989) International Journal of Radiation Oncology Biology Physics , vol.16 , Issue.6 , pp. 1623-1630
    • Kutcher, G.J.1    Burman, C.2
  • 11
    • 0025998401 scopus 로고
    • Fitting of normal tissue tolerance data to an analytic function
    • 10.1016/2F0360-3016/2891/2990172-Z
    • C. Burman, G. J. Kutcher, B. Emami, and M. Goitein, Fitting of normal tissue tolerance data to an analytic function., Int. J. Radiat. Oncol., Biol., Phys. 21 (1), 123-135 (1991) 10.1016/2F0360-3016/2891/2990172-Z.
    • (1991) Int. J. Radiat. Oncol., Biol., Phys. , vol.21 , Issue.1 , pp. 123-135
    • Burman, C.1    Kutcher, G.J.2    Emami, B.3    Goitein, M.4
  • 13
    • 0026656051 scopus 로고
    • Tumour and normal tissue responses to fractionated non-uniform dose delivery
    • 10.1080/09553009214552071
    • P. Kllman, A. Agren, and A. Brahme, Tumour and normal tissue responses to fractionated non-uniform dose delivery., Int. J. Radiat. Biol. 62 (2), 249-262 (1992). 10.1080/09553009214552071
    • (1992) Int. J. Radiat. Biol. , vol.62 , Issue.2 , pp. 249-262
    • Kllman, P.1    Agren, A.2    Brahme, A.3
  • 14
    • 0029791566 scopus 로고    scopus 로고
    • Long-term cardiac mortality after radiotherapy of breast cancer - Application of the relative seriality model
    • G. Gagliardi, I. Lax, A. Ottolenghi, and L. E. Rutqvist, Long-term cardiac mortality after radiotherapy of breast cancer-Application of the relative seriality model., Br. J. Radiol. 69 (825), 839-846 (1996). 10.1259/0007-1285-69-825-839 (Pubitemid 26325443)
    • (1996) British Journal of Radiology , vol.69 , Issue.825 , pp. 839-846
    • Gagliardi, G.1    Lax, I.2    Ottolenghi, A.3    Rutqvist, L.E.4
  • 15
    • 34247150396 scopus 로고    scopus 로고
    • NTCP modelling and pulmonary function tests evaluation for the prediction of radiation induced pneumonitis in non-small-cell lung cancer radiotherapy
    • DOI 10.1088/0031-9155/52/4/013, PII S0031915507258798, 013
    • I. Tsougos, P. Nilsson, K. Theodorou, E Kjellén, S. Ewers, O. Jarlman, B. K. Lind, C. Kappas, and P. Mavroidis, NTCP modelling and pulmonary function tests evaluation for the prediction of radiation induced pneumonitis in non-small-cell lung cancer radiotherapy., Phys. Med. Biol. 52 (4), 1055-1073 (2007). 10.1088/0031-9155/52/4/013 (Pubitemid 46646417)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.4 , pp. 1055-1073
    • Tsougos, I.1    Nilsson, P.2    Theodorou, K.3    Kjellen, E.4    Ewers, S.-B.5    Jarlman, O.6    Lind, B.K.7    Kappas, C.8    Mavroidis, P.9
  • 16
    • 77956605923 scopus 로고    scopus 로고
    • Cardiac toxicity and radiation dose to the heart in definitive treated non-small cell lung cancer
    • 10.3109/0284186X.2010.504736
    • T. Schytte, O. Hansen, T. Stolberg-Rohr, and C. Brink, Cardiac toxicity and radiation dose to the heart in definitive treated non-small cell lung cancer., Acta Oncol. 49 (7), 1058-1060 (2010). 10.3109/0284186X.2010.504736
    • (2010) Acta Oncol. , vol.49 , Issue.7 , pp. 1058-1060
    • Schytte, T.1    Hansen, O.2    Stolberg-Rohr, T.3    Brink, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.