메뉴 건너뛰기




Volumn 469, Issue 6, 2011, Pages 1766-1773

Distal radius osteotomy with volar locking plates based on computer simulation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTHRALGIA; ARTICLE; BONE GRAFT; BONE SCREW; CANCELLOUS BONE; CLINICAL ARTICLE; COMPUTER AIDED DESIGN; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; COMPUTER SIMULATION; ENDOPROSTHESIS LOOSENING; FEMALE; FRACTURE NONUNION; HUMAN; JOINT FUNCTION; METAPHYSIS; OSTEOTOMY; PRIORITY JOURNAL; RADIUS FRACTURE; TENDON INJURY; VOLAR PLATE FIXATION; WRIST;

EID: 79959554908     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1007/s11999-010-1748-z     Document Type: Article
Times cited : (87)

References (27)
  • 3
    • 0030767613 scopus 로고    scopus 로고
    • Displaced intra-articular fractures of the distal aspect of the radius: Long-term results in young adults after open reduction and internal fixation
    • Catalano LW 3rd, Cole RJ, Gelberman RH, Evanoff BA, Gilula LA, Borrelli J Jr. Displaced intra-articular fractures of the distal aspect of the radius: long-term results in young adults after open reduction and internal fixation. J Bone Joint Surg Am. 1997;79: 1290-1302.
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 1290-1302
    • Catalano III, L.W.1    Cole, R.J.2    Gelberman, R.H.3    Evanoff, B.A.4    Gilula, L.A.5    Borrelli Jr., J.6
  • 5
    • 0038651175 scopus 로고    scopus 로고
    • Osteosynthesis of distal radial fractures with a volar locking screw plate system
    • Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop. 2003;27:1-6.
    • (2003) Int Orthop , vol.27 , pp. 1-6
    • Drobetz, H.1    Kutscha-Lissberg, E.2
  • 6
    • 0020363733 scopus 로고
    • Correction of post-traumatic wrist deformity in adults by osteotomy, bone-grafting, and internal fixation
    • Fernandez DL. Correction of post-traumatic wrist deformity in adults by osteotomy, bone-grafting, and internal fixation. J Bone Joint Surg Am. 1982;64:1164-1178.
    • (1982) J Bone Joint Surg Am , vol.64 , pp. 1164-1178
    • Fernandez, D.L.1
  • 7
    • 0027266950 scopus 로고
    • Reconstructive procedures for malunion and traumatic arthritis
    • Fernandez DL. Reconstructive procedures for malunion and traumatic arthritis. Orthop Clin North Am. 1993;24:341-363.
    • (1993) Orthop Clin North Am , vol.24 , pp. 341-363
    • Fernandez, D.L.1
  • 9
    • 0028035442 scopus 로고
    • Surgery for posttraumatic wrist deformity: Radial osteotomy and/or ulnar shortening in 16 Colles' fractures
    • Hove LM, Molster AO. Surgery for posttraumatic wrist deformity: radial osteotomy and/or ulnar shortening in 16 Colles' fractures. Acta Orthop Scand. 1994;65:434-438.
    • (1994) Acta Orthop Scand , vol.65 , pp. 434-438
    • Hove, L.M.1    Molster, A.O.2
  • 10
    • 0036361455 scopus 로고    scopus 로고
    • Complications following distal radial fractures
    • Jupiter JB, Fernandez DL. Complications following distal radial fractures. Instr Course Lect. 2002;51:203-219.
    • (2002) Instr Course Lect , vol.51 , pp. 203-219
    • Jupiter, J.B.1    Fernandez, D.L.2
  • 11
    • 0029971919 scopus 로고    scopus 로고
    • A comparison of early and late reconstruction of malunited fractures of the distal end of the radius
    • Jupiter JB, Ring D. A comparison of early and late reconstruction of malunited fractures of the distal end of the radius. J Bone Joint Surg Am. 1996;78:739-748.
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 739-748
    • Jupiter, J.B.1    Ring, D.2
  • 12
    • 0026695706 scopus 로고
    • Computer-generated bone models in the planning of osteotomy of multidirectional distal radius malunions
    • Jupiter JB, Ruder J, Roth DA. Computer-generated bone models in the planning of osteotomy of multidirectional distal radius malunions. J Hand Surg Am. 1992;17:406-415.
    • (1992) J Hand Surg Am , vol.17 , pp. 406-415
    • Jupiter, J.B.1    Ruder, J.2    Roth, D.A.3
  • 13
    • 34548487815 scopus 로고    scopus 로고
    • Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: A case report
    • Klug RA, Press CM, Gonzalez MH. Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report. J Hand Surg Am. 2007;32:984-988.
    • (2007) J Hand Surg Am , vol.32 , pp. 984-988
    • Klug, R.A.1    Press, C.M.2    Gonzalez, M.H.3
  • 14
    • 0029886085 scopus 로고    scopus 로고
    • Reconstructive osteotomy for malunion of the distal radius
    • Ladd AL, Huene DS. Reconstructive osteotomy for malunion of the distal radius. Clin Orthop Relat Res. 1996;327:158-171.
    • (1996) Clin Orthop Relat Res , vol.327 , pp. 158-171
    • Ladd, A.L.1    Huene, D.S.2
  • 15
    • 36849066852 scopus 로고    scopus 로고
    • Immediate mobilization compared with conventional immobilization for the impacted nonoperatively treated proximal humeral fracture: A randomized controlled trial
    • Lefevre-Colau MM, Babinet A, Fayad F, Fermanian J, Anract P, Roren A, Kansao J, Revel M, Poiraudeau S. Immediate mobilization compared with conventional immobilization for the impacted nonoperatively treated proximal humeral fracture: a randomized controlled trial. J Bone Joint Surg Am. 2007;89:2582-2590.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 2582-2590
    • Lefevre-Colau, M.M.1    Babinet, A.2    Fayad, F.3    Fermanian, J.4    Anract, P.5    Roren, A.6    Kansao, J.7    Revel, M.8    Poiraudeau, S.9
  • 16
    • 33644660401 scopus 로고    scopus 로고
    • Surgical correction of dorsally angulated distal radius malunions with fixed angle volar plating: A case series
    • Malone KJ, Magnell TD, Freeman DC, Boyer MI, Placzek JD. Surgical correction of dorsally angulated distal radius malunions with fixed angle volar plating: a case series. J Hand Surg Am. 2006;31:366-372.
    • (2006) J Hand Surg Am , vol.31 , pp. 366-372
    • Malone, K.J.1    Magnell, T.D.2    Freeman, D.C.3    Boyer, M.I.4    Placzek, J.D.5
  • 17
    • 70349918441 scopus 로고    scopus 로고
    • Correction of severe wrist deformity following physeal arrest of the distal radius with the aid of a three-dimensional computer simulation
    • Murase T, Oka K, Moritomo H, Goto A, Sugamoto K, Yoshikawa H. Correction of severe wrist deformity following physeal arrest of the distal radius with the aid of a three-dimensional computer simulation. Arch Orthop Trauma Surg. 2009;129:1465-1471.
    • (2009) Arch Orthop Trauma Surg , vol.129 , pp. 1465-1471
    • Murase, T.1    Oka, K.2    Moritomo, H.3    Goto, A.4    Sugamoto, K.5    Yoshikawa, H.6
  • 18
    • 55849124682 scopus 로고    scopus 로고
    • Three-dimensional corrective osteotomy of malunited fractures of the upper extremity with use of a computer simulation system
    • Murase T, Oka K, Moritomo H, Goto A, Yoshikawa H, Sugamoto K. Three-dimensional corrective osteotomy of malunited fractures of the upper extremity with use of a computer simulation system. J Bone Joint Surg Am. 2008;90:2375-2389.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 2375-2389
    • Murase, T.1    Oka, K.2    Moritomo, H.3    Goto, A.4    Yoshikawa, H.5    Sugamoto, K.6
  • 19
    • 22544478434 scopus 로고    scopus 로고
    • Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates
    • Musgrave DS, Idler RS. Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates. J Hand Surg Am. 2005;30:743-749.
    • (2005) J Hand Surg Am , vol.30 , pp. 743-749
    • Musgrave, D.S.1    Idler, R.S.2
  • 20
    • 47649117681 scopus 로고    scopus 로고
    • Corrective osteotomy for malunited intra-articular fracture of the distal radius using a custom-made surgical guide based on three-dimensional computer simulation: Case report
    • Oka K, Moritomo H, Goto A, Sugamoto K, Yoshikawa H, Murase T. Corrective osteotomy for malunited intra-articular fracture of the distal radius using a custom-made surgical guide based on three-dimensional computer simulation: case report. J Hand Surg Am. 2008;33:835-840.
    • (2008) J Hand Surg Am , vol.33 , pp. 835-840
    • Oka, K.1    Moritomo, H.2    Goto, A.3    Sugamoto, K.4    Yoshikawa, H.5    Murase, T.6
  • 21
    • 73449136127 scopus 로고    scopus 로고
    • Accuracy analysis of three-dimensional bone surface models of the forearm constructed from multidetector computed tomography data
    • Oka K, Murase T, Moritomo H, Goto A, Sugamoto K, Yoshikawa H. Accuracy analysis of three-dimensional bone surface models of the forearm constructed from multidetector computed tomography data. Int J Med Robot. 2009;5:452-457.
    • (2009) Int J Med Robot , vol.5 , pp. 452-457
    • Oka, K.1    Murase, T.2    Moritomo, H.3    Goto, A.4    Sugamoto, K.5    Yoshikawa, H.6
  • 22
    • 77952777454 scopus 로고    scopus 로고
    • Corrective osteotomy using customized hydroxyapatite implants prepared by preoperative computer simulation
    • Oka K, Murase T, Moritomo H, Goto A, Sugamoto K, Yoshikawa H. Corrective osteotomy using customized hydroxyapatite implants prepared by preoperative computer simulation. Int J Med Robot. 2010;6:186-193.
    • (2010) Int J Med Robot , vol.6 , pp. 186-193
    • Oka, K.1    Murase, T.2    Moritomo, H.3    Goto, A.4    Sugamoto, K.5    Yoshikawa, H.6
  • 23
    • 33646840103 scopus 로고    scopus 로고
    • Current concepts in volar fixed-angle fixation of unstable distal radius fractures
    • Orbay JL, Touhami A. Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res. 2006;445:58-67.
    • (2006) Clin Orthop Relat Res , vol.445 , pp. 58-67
    • Orbay, J.L.1    Touhami, A.2
  • 24
    • 52449090861 scopus 로고    scopus 로고
    • Malunited fractures of the distal radius treated with corrective osteotomy using volar locking plate and a corticocancellous bone graft following immediate mobilisation
    • Osada D, Kamei S, Takai M, Tomizawa K, Tamai K. Malunited fractures of the distal radius treated with corrective osteotomy using volar locking plate and a corticocancellous bone graft following immediate mobilisation. Hand Surg. 2007;12:183-190.
    • (2007) Hand Surg , vol.12 , pp. 183-190
    • Osada, D.1    Kamei, S.2    Takai, M.3    Tomizawa, K.4    Tamai, K.5
  • 25
    • 0036212057 scopus 로고    scopus 로고
    • Outcome after corrective osteotomy for malunited fractures of the distal end of the radius
    • Prommersberger KJ, Van Schoonhoven J, Lanz UB. Outcome after corrective osteotomy for malunited fractures of the distal end of the radius. J Hand Surg Br. 2002;27:55-60.
    • (2002) J Hand Surg Br , vol.27 , pp. 55-60
    • Prommersberger, K.J.1    Van Schoonhoven, J.2    Lanz, U.B.3
  • 26
    • 0021339929 scopus 로고
    • The effects of angular and rotational deformities of both bones of the forearm: An in vitro study
    • Tarr RR, Garfinkel AI, Sarmiento A. The effects of angular and rotational deformities of both bones of the forearm: an in vitro study. J Bone Joint Surg Am. 1984;66:65-70.
    • (1984) J Bone Joint Surg Am , vol.66 , pp. 65-70
    • Tarr, R.R.1    Garfinkel, A.I.2    Sarmiento, A.3
  • 27
    • 33748437228 scopus 로고    scopus 로고
    • Corrective osteotomies in malunions of the distal radius: Do we get what we planned?
    • von Campe A, Nagy L, Arbab D, Dumont CE. Corrective osteotomies in malunions of the distal radius: do we get what we planned? Clin Orthop Relat Res. 2006;450:179-185.
    • (2006) Clin Orthop Relat Res , vol.450 , pp. 179-185
    • Von Campe, A.1    Nagy, L.2    Arbab, D.3    Dumont, C.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.