메뉴 건너뛰기




Volumn 1, Issue 1, 2011, Pages

Usefulness of hemodynamic sensors for physiologic cardiac pacing in heart failure patients

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL HEART PACEMAKER; AUTONOMIC NERVOUS SYSTEM; BREATHING RATE; CARDIAC RESYNCHRONIZATION THERAPY; CLOSED LOOP STIMULATION; DEFIBRILLATOR; EXERCISE TOLERANCE; HEART FAILURE; HEART PACING; HEART RATE; HEMODYNAMIC MONITORING; HEMODYNAMIC PARAMETERS; HEMODYNAMIC SENSOR; HUMAN; INOTROPISM; INTRACARDIAC VENTRICULAR IMPEDANCE; LUNG MINUTE VOLUME; PEAK ENDOCARDIAL ACCELERATION; PRIORITY JOURNAL; REVIEW; SENSOR; TACHYCARDIA; TRANSVALVULAR IMPEDANCE;

EID: 79959466205     PISSN: None     EISSN: 20900597     Source Type: Journal    
DOI: 10.4061/2011/925653     Document Type: Review
Times cited : (14)

References (47)
  • 2
    • 0026540645 scopus 로고
    • Chronotropic incompetence: A common and progressive finding in pacemaker patients
    • Gwinn N., Leman R., Kratz J., White J. K., Zile M. R., Gillette P., Chronotropic incompetence: a common and progressive finding in pacemaker patients American Heart Journal 1992 123 5 1216 1219
    • (1992) American Heart Journal , vol.123 , Issue.5 , pp. 1216-1219
    • Gwinn, N.1    Leman, R.2    Kratz, J.3    White, J.K.4    Zile, M.R.5    Gillette, P.6
  • 3
    • 0031951261 scopus 로고    scopus 로고
    • Cardiac output is a sensitive indicator of difference in exercise performance between single and dual sensor pacemakers
    • Leung S. K., Lau C. P., Tang M. O., Cardiac output is a sensitive indicator of difference in exercise performance between single and dual sensor pacemakers Pacing and Clinical Electrophysiology 1998 21 1 35 41
    • (1998) Pacing and Clinical Electrophysiology , vol.21 , Issue.1 , pp. 35-41
    • Leung, S.K.1    Lau, C.P.2    Tang, M.O.3
  • 4
    • 0016592834 scopus 로고
    • Haemodynamic effect of atrial triggered versus fixed rate pacing at rest and during exercise in complete heart block
    • Karloef I., Haemodynamic effect of atrial triggered versus fixed rate pacing at rest and during exercise in complete heart block Acta Medica Scandinavica 1975 197 3 195 206
    • (1975) Acta Medica Scandinavica , vol.197 , Issue.3 , pp. 195-206
    • Karloef, I.1
  • 5
    • 0020571182 scopus 로고
    • Atrial synchronized ventricular pacing: Contribution of the chronotropic response to improved exercise performance
    • Fananapazir L., Bennett D. H., Monks P., Atrial synchronized ventricular pacing: contribution of the chronotropic response to improved exercise performance Pacing and Clinical Electrophysiology 1983 6 3 601 610 (Pubitemid 13034523)
    • (1983) PACE - Pacing and Clinical Electrophysiology , vol.6 , Issue.3 I , pp. 601-610
    • Fananapazir, L.1    Bennett, D.H.2    Monks, P.3
  • 6
    • 0022387098 scopus 로고
    • Maintenance of exercise stroke volume during ventricular versus atrial synchronous pacing: Role of contractility
    • Ausubel K., Steingart R. M., Shimshi M., Klementowicz P., Furman S., Maintenance of exercise stroke volume during ventricular versus atrial synchronous pacing: role of contractility Circulation 1985 72 5 1037 1043 (Pubitemid 16205404)
    • (1985) Circulation , vol.72 , Issue.5 , pp. 1037-1043
    • Ausubel, K.1    Steingart, R.M.2    Shimshi, M.3
  • 7
    • 0024208061 scopus 로고
    • The importance of different atrioventricular intervals for exercise capacity
    • DOI 10.1111/j.1540-8159.1988.tb03951.x
    • Ryden L., Karlsson O., Kristensson B. E., The importance of different atrioventricular intervals for exercise capacity Pacing and Clinical Electrophysiology 1988 11 7 1051 1062 (Pubitemid 19003497)
    • (1988) PACE - Pacing and Clinical Electrophysiology , vol.11 , Issue.7 , pp. 1051-1062
    • Ryden, L.1    Karlsson, O.2    Kristensson, B.-E.3
  • 10
    • 0020445149 scopus 로고
    • Central venous oxygen saturation for the control of automatic rate-responsive pacing
    • DOI 10.1111/j.1540-8159.1982.tb06564.x
    • Wirtzfeld A., Goedel Meinen L., Bock T., Central venous oxygen saturation for the control of automatic rate-responsive pacing Pacing and Clinical Electrophysiology 1982 5 6 829 835 (Pubitemid 13178898)
    • (1982) PACE - Pacing and Clinical Electrophysiology , vol.5 , Issue.6 , pp. 829-835
    • Wirtzfeld, A.1    Goedel Meinen, L.2    Bock, T.3
  • 11
    • 0023221732 scopus 로고
    • Rate-responsive pacing: Biosensor reliability and physiological sensitivity
    • DOI 10.1111/j.1540-8159.1987.tb04507.x
    • Rossi P., Rate-responsive pacing: biosensor reliability and physiological sensitivity Pacing and Clinical Electrophysiology 1987 10 3 454 466 (Pubitemid 17095493)
    • (1987) PACE - Pacing and Clinical Electrophysiology , vol.10 , Issue.3 I , pp. 454-466
    • Rossi, P.1
  • 13
    • 0020659590 scopus 로고
    • Initial experience with a physiological, rate responsive pacemaker
    • Donaldson R. M., Fox K., Rickards A. F., Initial experience with a physiological, rate responsive pacemaker British Medical Journal 1983 286 6366 667 671 (Pubitemid 13147650)
    • (1983) British Medical Journal , vol.286 , Issue.6366 , pp. 667-671
    • Donaldson, R.M.1    Fox, K.2    Rickards, A.F.3
  • 15
    • 0022344721 scopus 로고
    • Respiration-dependent ventricular pacing compared with fixed ventricular and atrial-ventricular synchronous pacing: Aerobic and hemodynamic variables
    • Rossi P., Rognoni G., Occhetta E., Respiration-dependent ventricular pacing compared with fixed ventricular and atrial-ventricular synchronous pacing: aerobic and hemodynamic variables Journal of the American College of Cardiology 1985 6 3 646 652 (Pubitemid 16219245)
    • (1985) Journal of the American College of Cardiology , vol.6 , Issue.3 , pp. 646-652
    • Rossi, P.1    Rognoni, G.2    Occhetta, E.3
  • 16
    • 0024246816 scopus 로고
    • Relationship between heart rate and minute ventilation, tidal volume and respiratory rate during brief and low level exercise
    • DOI 10.1111/j.1540-8159.1988.tb06321.x
    • Vai F., Bonnet J. L., Ritter P., Pioger G., Relationship between heart rate and minute ventilation, tidal volume and respiratory rate during brief and low level exercise Pacing and Clinical Electrophysiology 1988 11 11 1860 1865 (Pubitemid 19010535)
    • (1988) PACE - Pacing and Clinical Electrophysiology , vol.11 , Issue.11 II , pp. 1860-1865
    • Vai, F.1    Bonnet, J.L.2    Ritter, P.3    Pioger, G.4
  • 21
    • 34548223129 scopus 로고    scopus 로고
    • Impact of rate-modulated pacing on quality of life and exercise capacity-Evidence from the Advanced Elements of Pacing Randomized Controlled Trial (ADEPT)
    • DOI 10.1016/j.hrthm.2007.05.021, PII S154752710700598X
    • Lamas G. A., Knight J. D., Sweeney M. O., Mianulli M., Jorapur V., Khalighi K., Cook J. R., Silverman R., Rosenthal L., Clapp-Channing N., Lee K. L., Mark D. B., Impact of rate-modulated pacing on quality of life and exercise capacity-evidence from the advanced elements of pacing randomized controlled trial (ADEPT) Heart Rhythm 2007 4 9 1125 1132 (Pubitemid 47336847)
    • (2007) Heart Rhythm , vol.4 , Issue.9 , pp. 1125-1132
    • Lamas, G.A.1    Knight, J.D.2    Sweeney, M.O.3    Mianulli, M.4    Jorapur, V.5    Khalighi, K.6    Cook, J.R.7    Silverman, R.8    Rosenthal, L.9    Clapp-Channing, N.10    Lee, K.L.11    Mark, D.B.12
  • 22
    • 79959460379 scopus 로고
    • Physiologic pacing based on beat-to-beat measurement of right ventricular dP/dT max: Initially feasibility studies in man
    • Sharma A., Sutton R., Bennet T., Physiologic pacing based on beat-to-beat measurement of right ventricular dP/dT max: initially feasibility studies in man Journal of the American College of Cardiology 1986 7 3A
    • (1986) Journal of the American College of Cardiology , vol.7
    • Sharma, A.1    Sutton, R.2    Bennet, T.3
  • 25
    • 0036461638 scopus 로고    scopus 로고
    • PEA I and PEA II based implantable haemodynamic monitor: Pre clinical studies in sheep
    • DOI 10.1053/eupc.2001.0204
    • Plicchi G., Marcelli E., Parlapiano M., Bombardini T., PEA I and PEA II based implantable haemodynamic monitor: pre clinical studies in sheep Europace 2002 4 1 49 54 (Pubitemid 36124394)
    • (2002) Europace , vol.4 , Issue.1 , pp. 49-54
    • Plicchi, G.1    Marcelli, E.2    Parlapiano, M.3    Bombardini, T.4
  • 26
    • 79959401818 scopus 로고    scopus 로고
    • Hemodynamics monitoring in the atrium with a peak endocardial acceleration sensor: Preliminary results from a pilot study
    • Kubler L., Burban M., Anselme F., Hemodynamics monitoring in the atrium with a peak endocardial acceleration sensor: preliminary results from a pilot study Europace 2008 10 supplement 1 82
    • (2008) Europace , vol.10 , Issue.SUPPL. 1 , pp. 82
    • Kubler, L.1    Burban, M.2    Anselme, F.3
  • 27
    • 0026592069 scopus 로고
    • Intracardiac impedance to determine sympathetic activity in rate responsive pacing
    • Schaldach M., Hutten H., Intracardiac impedance to determine sympathetic activity in rate responsive pacing Pacing and Clinical Electrophysiology 1992 15 11 1778 1786
    • (1992) Pacing and Clinical Electrophysiology , vol.15 , Issue.11 , pp. 1778-1786
    • Schaldach, M.1    Hutten, H.2
  • 29
    • 27744600806 scopus 로고    scopus 로고
    • Impact of a right ventricular impedance sensor on the cardiovascular responses to exercise in pacemaker dependent patients
    • Cook L., Tomczak C., Busse E., Tsang J., Wojcik W., Haennel R. G., Impact of a right ventricular impedance sensor on the cardiovascular responses to exercise in pacemaker dependent patients Indian Pacing and Electrophysiology Journal 2005 5 3 160 174 (Pubitemid 41581741)
    • (2005) Indian Pacing and Electrophysiology Journal , vol.5 , Issue.3 , pp. 160-174
    • Cook, L.1    Tomczak, C.2    Busse, E.3    Tsang, J.4    Wojcik, W.5    Haennel, R.G.6
  • 30
    • 0037378704 scopus 로고    scopus 로고
    • The DDDR closed loop stimulation for the prevention of vasovagal syncope: Results from the INVASY prospective feasibility registry
    • DOI 10.1053/eupc.2002.0292
    • Occhetta E., Bortnik M., Vassanelli C., The DDDR closed loop stimulation for the prevention of vasovagal syncope: results from the INVASY prospective feasibility registry Europace 2003 5 2 153 162 (Pubitemid 36372373)
    • (2003) Europace , vol.5 , Issue.2 , pp. 153-162
    • Occhetta, E.1    Bortnik, M.2    Vassanelli, C.3
  • 32
    • 79959479380 scopus 로고    scopus 로고
    • A long-term follow-up in a selected population implanted with DDDR closed loop stimulation (CLS) for vasovagal syncope prevention
    • Occhetta E., Dell'Era G., Bortnik M., A long-term follow-up in a selected population implanted with DDDR closed loop stimulation (CLS) for vasovagal syncope prevention Europace 2008 10 supplement 1 72
    • (2008) Europace , vol.10 , Issue.SUPPL. 1 , pp. 72
    • Occhetta, E.1    Dell'Era, G.2    Bortnik, M.3
  • 33
    • 0029911279 scopus 로고    scopus 로고
    • Transvalvular impedance (TVI) recording under electrical and pharmocological cardiac stimulation
    • Di Gregorio F., Morra A., Finesso M., Bongiorni M. G., Transvalvular impedance (TVI) recording under electrical and pharmocological cardiac stimulation Pacing and Clinical Electrophysiology 1996 19 11 1689 1693 (Pubitemid 26398433)
    • (1996) PACE - Pacing and Clinical Electrophysiology , vol.19 , Issue.11 II , pp. 1689-1693
    • Di Gregorio, F.1    Morra, A.2    Finesso, M.3    Bongiorni, M.G.4
  • 37
    • 18144415246 scopus 로고    scopus 로고
    • Hemodynamic assessment with implantable pacemakers: How feasible and reliable is it?
    • Milan, Italy Springer
    • Chirife R., Raviele A., Hemodynamic assessment with implantable pacemakers: how feasible and reliable is it? Cardiac Arrhythmias 2003 2003 Milan, Italy Springer 705 712
    • (2003) Cardiac Arrhythmias 2003 , pp. 705-712
    • Chirife, R.1    Raviele, A.2
  • 38
    • 18144398007 scopus 로고    scopus 로고
    • Transvalvular impedante: Does it allow automatic capture detection?
    • Milan, Italy Springer
    • Bongiorni M. G., Soldati E., Arena G., Raviele A., Transvalvular impedante: does it allow automatic capture detection? Cardiac Arrhythmias 2003 2003 Milan, Italy Springer 733 739
    • (2003) Cardiac Arrhythmias 2003 , pp. 733-739
    • Bongiorni, M.G.1    Soldati, E.2    Arena, G.3    Raviele, A.4
  • 39
    • 0032408605 scopus 로고    scopus 로고
    • Treatment of malignant primary vasodepressive neurocardiogenic syncope with a rate responsive pacemaker driven by heart contractility
    • DOI 10.1111/j.1540-8159.1998.tb00050.x
    • Deharo J. C., Peyre J. P., Ritter P. H., Chalvidan T., Le Tallec L., Djiane P., Treatment of malignant primary vasodepressive neurocardiogenic syncope with a rate responsive pacemaker driven by heart contractility Pacing and Clinical Electrophysiology 1998 21 12 2688 2690 (Pubitemid 29031418)
    • (1998) PACE - Pacing and Clinical Electrophysiology , vol.21 , Issue.12 , pp. 2688-2690
    • Deharo, J.C.1    Peyre, J.P.2    Ritter, P.H.3    Chalvidan, T.4    Le Tallec, L.5    Djiane, P.6
  • 41
    • 79959381770 scopus 로고    scopus 로고
    • AV delay optimization using ventricular impedante
    • Ravazzi A. P., Diotallevi P., Provera M. F., AV delay optimization using ventricular impedante Europace 2001 2 supplement C C26
    • (2001) Europace , vol.2 , Issue.SUPPL. C , pp. 26
    • Ravazzi, A.P.1    Diotallevi, P.2    Provera, M.F.3
  • 42
    • 77951953999 scopus 로고    scopus 로고
    • Device-based impedance measurement is a useful and accurate tool for direct assessment of intrathoracic fluid accumulation in heart failure
    • Becher J., Kaufmann S. G., Paule S., Fahn B., Skerl O., Bauer W. R., Ertl G., Maier S. K. G., Device-based impedance measurement is a useful and accurate tool for direct assessment of intrathoracic fluid accumulation in heart failure Europace 2010 12 5 731 740
    • (2010) Europace , vol.12 , Issue.5 , pp. 731-740
    • Becher, J.1    Kaufmann, S.G.2    Paule, S.3    Fahn, B.4    Skerl, O.5    Bauer, W.R.6    Ertl, G.7    Maier, S.K.G.8
  • 44
    • 77950884226 scopus 로고    scopus 로고
    • Combined heart failure device diagnostics identify patients at higher risk of subsequent heart failure hospitalizations: Results from PARTNERS HF (Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients with Heart Failure) study
    • Whellan D. J., Ousdigian K. T., Al-Khatib S. M., Pu W., Sarkar S., Porter C. B., Pavri B. B., O'Connor C. M., Combined heart failure device diagnostics identify patients at higher risk of subsequent heart failure hospitalizations: results from PARTNERS HF (Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure) study Journal of the American College of Cardiology 2010 55 17 1803 1810
    • (2010) Journal of the American College of Cardiology , vol.55 , Issue.17 , pp. 1803-1810
    • Whellan, D.J.1    Ousdigian, K.T.2    Al-Khatib, S.M.3    Pu, W.4    Sarkar, S.5    Porter, C.B.6    Pavri, B.B.7    O'Connor, C.M.8
  • 45
    • 45849110223 scopus 로고    scopus 로고
    • Validation of a peak endocardial acceleration-based algorithm to optimize cardiac resynchronization: Early clinical results
    • DOI 10.1093/europace/eun125
    • Delnoy P. P., Marcelli E., Oudeluttikhuis H., Nicastia D., Renesto F., Cercenelli L., Plicchi G., Validation of a peak endocardial acceleration-based algorithm to optimize cardiac resynchronization: early clinical results Europace 2008 10 7 801 808 (Pubitemid 351882066)
    • (2008) Europace , vol.10 , Issue.7 , pp. 801-808
    • Delnoy, P.P.1    Marcelli, E.2    Oudeluttikhuis, H.3    Nicastia, D.4    Renesto, F.5    Cercenelli, L.6    Plicchi, G.7
  • 47


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.