메뉴 건너뛰기




Volumn 37, Issue 7, 2011, Pages 1002-1007

Flat-oval root canal preparation with self-adjusting file instrument: A micro-computed tomography study

Author keywords

Micro computed tomography; nickel titanium instruments; root canal preparation; self adjusting file

Indexed keywords


EID: 79959375814     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joen.2011.03.017     Document Type: Article
Times cited : (112)

References (22)
  • 1
    • 77949454680 scopus 로고    scopus 로고
    • The self-adjusting file (SAF): Part 1 - Respecting the root canal anatomy: A new concept of endodontic files and its implementation
    • Z. Metzger, E. Teperovich, R. Zary, R. Cohen, and R. Hof The self-adjusting file (SAF): part 1 - respecting the root canal anatomy: a new concept of endodontic files and its implementation J Endod 36 2010 679 690
    • (2010) J Endod , vol.36 , pp. 679-690
    • Metzger, Z.1    Teperovich, E.2    Zary, R.3    Cohen, R.4    Hof, R.5
  • 2
    • 53349161917 scopus 로고    scopus 로고
    • Clinical implications and microbiology of bacterial persistence after treatment procedures
    • J.F. Siqueira Jr. , and I.N. Roas Clinical implications and microbiology of bacterial persistence after treatment procedures J Endod 34 2008 1291 1301
    • (2008) J Endod , vol.34 , pp. 1291-1301
    • Siqueira Jr., J.F.1    Roas, I.N.2
  • 3
    • 67649224822 scopus 로고    scopus 로고
    • Effects of root canal preparation on apical geometry assessed by micro-computed tomography
    • F. Paqué, D. Ganahl, and O.A. Peters Effects of root canal preparation on apical geometry assessed by micro-computed tomography J Endod 35 2009 1056 1059
    • (2009) J Endod , vol.35 , pp. 1056-1059
    • Paqué, F.1    Ganahl, D.2    Peters, O.A.3
  • 4
    • 4143097917 scopus 로고    scopus 로고
    • Current challenges and concepts in the preparation of root canal systems: A review
    • O.A. Peters Current challenges and concepts in the preparation of root canal systems: a review J Endod 30 2004 559 567 (Pubitemid 39092208)
    • (2004) Journal of Endodontics , vol.30 , Issue.8 , pp. 559-567
    • Peters, O.A.1
  • 5
    • 0036582871 scopus 로고    scopus 로고
    • Effectiveness of manual and rotary instrumentation techniques for cleaning flattened root canals
    • J.V. Barbizam, L.F. Fariniuk, M.A. Marchesan, J.D. Pécora, and M.D. Sousa-Neto Effectiveness of manual and rotary instrumentation techniques for cleaning flattened root canals J Endod 28 2002 365 366
    • (2002) J Endod , vol.28 , pp. 365-366
    • Barbizam, J.V.1    Fariniuk, L.F.2    Marchesan, M.A.3    Pécora, J.D.4    Sousa-Neto, M.D.5
  • 6
    • 78649463329 scopus 로고    scopus 로고
    • Histological evaluation of the effectiveness of increased apical enlargement for cleaning the apical third of curved canals
    • V.J. Fornari, Y.T. Silva-Sousa, J.R. Vanni, J.D. Pécora, M.A. Versiani, and M.D. Sousa-Neto Histological evaluation of the effectiveness of increased apical enlargement for cleaning the apical third of curved canals Int Endod J 43 2010 988 994
    • (2010) Int Endod J , vol.43 , pp. 988-994
    • Fornari, V.J.1    Silva-Sousa, Y.T.2    Vanni, J.R.3    Pécora, J.D.4    Versiani, M.A.5    Sousa-Neto, M.D.6
  • 7
    • 76349111601 scopus 로고    scopus 로고
    • Effectiveness of different final irrigation protocols in removing debris in flattened root canals
    • M.R. Nadalin, D.E. Perez, L.P. Vansan, C. Paschoala, M.D. Sousa-Neto, and P.C. Saquy Effectiveness of different final irrigation protocols in removing debris in flattened root canals Braz Dent J 20 2009 211 214
    • (2009) Braz Dent J , vol.20 , pp. 211-214
    • Nadalin, M.R.1    Perez, D.E.2    Vansan, L.P.3    Paschoala, C.4    Sousa-Neto, M.D.5    Saquy, P.C.6
  • 8
    • 33947522624 scopus 로고    scopus 로고
    • Ex vivo analysis of the debris remaining in flattened root canals of vital and nonvital teeth after biomechanical preparation with Ni-Ti rotary instruments
    • E.W. Sasaki, M.A. Versiani, D.E. Perez, M.D. Sousa-Neto, Y.T. Silva-Sousa, and R.G. Silva Ex vivo analysis of the debris remaining in flattened root canals of vital and nonvital teeth after biomechanical preparation with Ni-Ti rotary instruments Braz Dent J 17 2006 233 236
    • (2006) Braz Dent J , vol.17 , pp. 233-236
    • Sasaki, E.W.1    Versiani, M.A.2    Perez, D.E.3    Sousa-Neto, M.D.4    Silva-Sousa, Y.T.5    Silva, R.G.6
  • 9
    • 76449093089 scopus 로고    scopus 로고
    • Comparison of three techniques for preparing oval-shaped root canals
    • N.A. Taha, T. Ozawa, and H.H. Messer Comparison of three techniques for preparing oval-shaped root canals J Endod 36 2010 532 535
    • (2010) J Endod , vol.36 , pp. 532-535
    • Taha, N.A.1    Ozawa, T.2    Messer, H.H.3
  • 10
    • 79952780885 scopus 로고    scopus 로고
    • Root canal preparation of maxillary molars with the self-adjusting file: A micro-computed tomography study
    • O.A. Peters, and F. Paqué Root canal preparation of maxillary molars with the self-adjusting file: a micro-computed tomography study J Endod 37 2011 517 521
    • (2011) J Endod , vol.37 , pp. 517-521
    • Peters, O.A.1    Paqué, F.2
  • 11
    • 77949456326 scopus 로고    scopus 로고
    • The self-adjusting file (SAF): Part 2 - Mechanical analysis
    • R. Hof, V. Perevalov, M. Eltanani, R. Zary, and Z. Metzger The self-adjusting file (SAF): part 2 - mechanical analysis J Endod 36 2010 691 696
    • (2010) J Endod , vol.36 , pp. 691-696
    • Hof, R.1    Perevalov, V.2    Eltanani, M.3    Zary, R.4    Metzger, Z.5
  • 12
    • 77949461185 scopus 로고    scopus 로고
    • The self-adjusting file (SAF): Part 3 - Removal of debris and smear layer: A scanning electron microscope study
    • Z. Metzger, E. Teperovich, R. Cohen, R. Zary, F. Paqué, and M. Hülsmann The self-adjusting file (SAF): part 3 - removal of debris and smear layer: a scanning electron microscope study J Endod 36 2010 697 702
    • (2010) J Endod , vol.36 , pp. 697-702
    • Metzger, Z.1    Teperovich, E.2    Cohen, R.3    Zary, R.4    Paqué, F.5    Hülsmann, M.6
  • 13
    • 77955309865 scopus 로고    scopus 로고
    • Root canal preparation with a novel nickel-titanium instrument evaluated with micro-computed tomography: Canal surface preparation over time
    • O.A. Peters, C. Boessler, and F. Paqué Root canal preparation with a novel nickel-titanium instrument evaluated with micro-computed tomography: canal surface preparation over time J Endod 36 2010 1068 1072
    • (2010) J Endod , vol.36 , pp. 1068-1072
    • Peters, O.A.1    Boessler, C.2    Paqué, F.3
  • 14
    • 77957978070 scopus 로고    scopus 로고
    • Ability of chemomechanical preparation with either rotary instruments or self-adjusting file to disinfect oval-shaped root canals
    • J.F. Siqueira Jr. , F.R. Alves, B.M. Almeida, J.C. de Oliveira, and I.N. Roas Ability of chemomechanical preparation with either rotary instruments or self-adjusting file to disinfect oval-shaped root canals J Endod 36 2010 1860 1865
    • (2010) J Endod , vol.36 , pp. 1860-1865
    • Siqueira Jr., J.F.1    Alves, F.R.2    Almeida, B.M.3    De Oliveira, J.C.4    Roas, I.N.5
  • 15
    • 58149348549 scopus 로고    scopus 로고
    • Root canal morphology of the mesiobuccal root of maxillary first molars: A micro-computed tomographic analysis
    • F. Somma, D. Leoni, G. Plotino, N.M. Grande, and A. Plasschaert Root canal morphology of the mesiobuccal root of maxillary first molars: a micro-computed tomographic analysis Int Endod J 42 2009 165 174
    • (2009) Int Endod J , vol.42 , pp. 165-174
    • Somma, F.1    Leoni, D.2    Plotino, G.3    Grande, N.M.4    Plasschaert, A.5
  • 16
    • 78049395592 scopus 로고    scopus 로고
    • The quality of root canal preparation and root canal obturation in canals treated with rotary versus self-adjusting files: A three-dimensional micro-computed tomographic study
    • Z. Metzger, R. Zary, R. Cohen, E. Teperovich, and F. Paqué The quality of root canal preparation and root canal obturation in canals treated with rotary versus self-adjusting files: a three-dimensional micro-computed tomographic study J Endod 36 2010 1569 1573
    • (2010) J Endod , vol.36 , pp. 1569-1573
    • Metzger, Z.1    Zary, R.2    Cohen, R.3    Teperovich, E.4    Paqué, F.5
  • 17
    • 33645101292 scopus 로고    scopus 로고
    • Mechanical preparation of root canals: Shaping goals, techniques and means
    • M. Hülsmann, O.A. Peters, and P.M.H. Dummer Mechanical preparation of root canals: shaping goals, techniques and means Endod Topics 10 2005 30 76
    • (2005) Endod Topics , vol.10 , pp. 30-76
    • Hülsmann, M.1    Peters, O.A.2    Dummer, P.M.H.3
  • 18
    • 0022144322 scopus 로고
    • The relationship between dentin microhardness and tubule density
    • D. Pashley, A. Okabe, and P. Parham The relationship between dentin microhardness and tubule density Endod Dent Traumatol 1 1985 176 179
    • (1985) Endod Dent Traumatol , vol.1 , pp. 176-179
    • Pashley, D.1    Okabe, A.2    Parham, P.3
  • 19
    • 0032151753 scopus 로고    scopus 로고
    • An evaluation of canal morphology at different levels of root resection in mandibular incisors
    • M.J. Mauger, W.G. Schindler, and W.A. Walker 3rd An evaluation of canal morphology at different levels of root resection in mandibular incisors J Endod 24 1998 607 609 (Pubitemid 128704259)
    • (1998) Journal of Endodontics , vol.24 , Issue.9 , pp. 607-609
    • Mauger, M.J.1    Schindler, W.G.2    Walker III, W.A.3
  • 21
    • 3242777752 scopus 로고    scopus 로고
    • Endodontic working width: Current concepts and techniques
    • DOI 10.1016/j.cden.2003.12.006, PII S001185320300096X
    • Y.T. Jou, B. Karabucak, J. Levin, and D. Liu Endodontic working width: current concepts and techniques Dent Clin North Am 48 2004 323 335 (Pubitemid 38968958)
    • (2004) Dental Clinics of North America , vol.48 , Issue.1 , pp. 323-335
    • Jou, Y.-T.1    Karabucak, B.2    Levin, J.3    Liu, D.4
  • 22
    • 0038725613 scopus 로고    scopus 로고
    • Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile. Part 2. Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth
    • DOI 10.1046/j.1365-2591.2003.00644.x
    • E. Schäfer, and R. Schlingemann Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile: part 2 - cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth Int Endod J 36 2003 208 217 (Pubitemid 37255744)
    • (2003) International Endodontic Journal , vol.36 , Issue.3 , pp. 208-217
    • Schafer, E.1    Schlingemann, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.