메뉴 건너뛰기




Volumn 21, Issue 6, 2011, Pages 1311-1322

Unenhanced calf MR angiography at 3.0 T using electrocardiography-gated partial-fourier fast spin echo imaging with variable flip angle

Author keywords

Fast spin echo; Magnetic resonance angiography; Peripheral arterial occlusive disease; Unenhanced

Indexed keywords

ADULT; AGED; ARTERY OCCLUSION; ARTICLE; CLINICAL EVALUATION; COMPARATIVE STUDY; CONTRAST ENHANCEMENT; CONTROLLED STUDY; DIAGNOSTIC TEST ACCURACY STUDY; ELECTROCARDIOGRAPHY GATED PARTIAL FOURIER FAST SPIN ECHO IMAGING; ELECTRODIAGNOSIS; FEMALE; HEART ARRHYTHMIA; HEART ATRIUM FIBRILLATION; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; IMAGING AND DISPLAY; LEG ARTERY; MAGNETIC RESONANCE ANGIOGRAPHY; MAJOR CLINICAL STUDY; MALE; PERIPHERAL OCCLUSIVE ARTERY DISEASE; PERONEUS ARTERY; POPLITEAL ARTERY; PRIORITY JOURNAL; RADIODIAGNOSIS; SENSITIVITY AND SPECIFICITY; STANDARD; TACHYCARDIA; TIBIAL ARTERY; UNENHANCED;

EID: 79959240120     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-010-2028-8     Document Type: Article
Times cited : (11)

References (29)
  • 1
    • 0026659372 scopus 로고
    • Lower extremity arterial disease and the aging process: A review
    • Vogt MT, Wolfson SK, Kuller LH (1992) Lower extremity arterial disease and the aging process: a review. J Clin Epidemiol 45:529-542
    • (1992) J Clin Epidemiol , vol.45 , pp. 529-542
    • Vogt, M.T.1    Wolfson, S.K.2    Kuller, L.H.3
  • 4
    • 55249101323 scopus 로고    scopus 로고
    • Feasibility of peripheral contrast-enhanced magnetic resonance angiography at 3.0 Tesla with a hybrid technique: Comparison with digital subtraction angiography
    • Berg F, Bangard C, Bovenschulte H et al (2008) Feasibility of peripheral contrast-enhanced magnetic resonance angiography at 3.0 Tesla with a hybrid technique: comparison with digital subtraction angiography. Invest Radiol 43:642-649
    • (2008) Invest Radiol , vol.43 , pp. 642-649
    • Berg, F.1    Bangard, C.2    Bovenschulte, H.3
  • 5
    • 0037282832 scopus 로고    scopus 로고
    • MR angiography of the abdominal aorta and peripheral vessels
    • DOI 10.1016/S0033-8389(02)00062-3, PII S0338389002000623
    • Ho VB, Corse WR (2003) MR angiography of the abdominal aorta and peripheral vessels. Radiol Clin N Am 41:115-144 (Pubitemid 36284688)
    • (2003) Radiologic Clinics of North America , vol.41 , Issue.1 , pp. 115-144
    • Ho, V.B.1    Corse, W.R.2
  • 6
    • 44849140711 scopus 로고    scopus 로고
    • MR angiography of the lower extremities
    • Ersoy H, Rybicki FJ (2003) MR angiography of the lower extremities. Am J Roentgenol 190:1675-1684
    • (2003) Am J Roentgenol , vol.190 , pp. 1675-1684
    • Ersoy, H.1    Rybicki, F.J.2
  • 7
    • 67650284716 scopus 로고    scopus 로고
    • Peripheral bolus-chase MR angiography: Analysis of risk factors for nondiagnostic image quality of the calf vessels - A combined retrospective and prospective study
    • Dinter DJ, Neff KW, Visciani G et al (2009) Peripheral bolus-chase MR angiography: analysis of risk factors for nondiagnostic image quality of the calf vessels-a combined retrospective and prospective study. Am J Roentgenol 193:234-240
    • (2009) Am J Roentgenol , vol.193 , pp. 234-240
    • Dinter, D.J.1    Neff, K.W.2    Visciani, G.3
  • 8
    • 7944223406 scopus 로고    scopus 로고
    • Decreased venous contamination on 3D gadolinium-enhanced bolus chase peripheral MR angiography using thigh compression
    • 10
    • Zhang HL, Ho BY, Chao M et al (2004) Decreased venous contamination on 3D gadolinium-enhanced bolus chase peripheral MR angiography using thigh compression. Am J Roentgenol 183(1041-10):47
    • (2004) Am J Roentgenol , vol.183 , Issue.1041 , pp. 47
    • Zhang, H.L.1    Ho, B.Y.2    Chao, M.3
  • 13
    • 77952312775 scopus 로고    scopus 로고
    • Retrospective analysis of patients for development of nephrogenic systemic fibrosis following conventional angiography using gadolinium-based contrast agents
    • Hoppe H, Spagnuolo S, Froehlich JM et al (2010) Retrospective analysis of patients for development of nephrogenic systemic fibrosis following conventional angiography using gadolinium-based contrast agents. Eur Radiol 20:595-603
    • (2010) Eur Radiol , vol.20 , pp. 595-603
    • Hoppe, H.1    Spagnuolo, S.2    Froehlich, J.M.3
  • 15
    • 0037950207 scopus 로고    scopus 로고
    • Peripheral MR angiography: Separation of arteries from veins with flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-Fourier fast spin-echo imaging
    • DOI 10.1148/radiol.2273020227
    • Miyazaki M, Takai H, Sugiura S et al (2003) Peripheral MR angiography: separation of arteries from veins with flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-fourier fast spin-echo imaging. Radiology 227:890-896 (Pubitemid 36583053)
    • (2003) Radiology , vol.227 , Issue.3 , pp. 890-896
    • Miyazaki, M.1    Takai, H.2    Sugiura, S.3    Wada, H.4    Kuwahara, R.5    Urata, J.6
  • 17
    • 79959240470 scopus 로고    scopus 로고
    • A novel noncontrast MR angiography technique using triggered non-selective refocused SPACE for improved spatial resolution and speed
    • Xu J, Weale P, Laub G et al (2008) A novel noncontrast MR angiography technique using triggered non-selective refocused SPACE for improved spatial resolution and speed. Proc Intl Soc Mag Reson Med 16:730
    • (2008) Proc Intl Soc Mag Reson Med , vol.16 , pp. 730
    • Xu, J.1    Weale, P.2    Laub, G.3
  • 18
    • 70349266127 scopus 로고    scopus 로고
    • Three-dimensional electrocardiographically gated variable flip angle FSE imaging for MR angiography of the hands at 3.0 T: Initial experience
    • Lim RP, Storey P, Atanasova IP et al (2009) Three-dimensional electrocardiographically gated variable flip angle FSE imaging for MR angiography of the hands at 3.0 T: initial experience. Radiology 252:874-881
    • (2009) Radiology , vol.252 , pp. 874-881
    • Lim, R.P.1    Storey, P.2    Atanasova, I.P.3
  • 19
    • 34249023605 scopus 로고    scopus 로고
    • High-resolution magnetic resonance angiography of the lower extremities with a dedicated 36-element matrix coil at 3 Tesla
    • DOI 10.1097/01.rli.0000263183.66407.69, PII 0000442420070600000020
    • Kramer H, Michaely HJ, Matschl V et al (2007) High-resolution magnetic resonance angiography of the lower extremities with a dedicated 36-element matrix coil at 3 Tesla. Invest Radiol 42:477-483 (Pubitemid 46788749)
    • (2007) Investigative Radiology , vol.42 , Issue.6 , pp. 477-483
    • Kramer, H.1    Michaely, H.J.2    Matschl, V.3    Schmitt, P.4    Reiser, M.F.5    Schoenberg, S.O.6
  • 20
    • 0001859044 scopus 로고
    • A technique for the measurement of attitudes
    • Likert R (1932) A technique for the measurement of attitudes. Arch Psychol 140:1-55
    • (1932) Arch Psychol , vol.140 , pp. 1-55
    • Likert, R.1
  • 21
    • 33645130692 scopus 로고    scopus 로고
    • Renal arteries: Comparison of steady-state free precession MR angiography and contrast-enhanced MR angiography
    • Herborn CU, Watkins DM, Runge VM et al (2006) Renal arteries: comparison of steady-state free precession MR angiography and contrast-enhanced MR angiography. Radiology 239:263-268
    • (2006) Radiology , vol.239 , pp. 263-268
    • Herborn, C.U.1    Watkins, D.M.2    Runge, V.M.3
  • 22
    • 0027934916 scopus 로고
    • Peripheral vascular occlusive disease: Accuracy and reliability of time-of-flight MR angiography
    • McCauley TR, Monib A, Dickey KW et al (1994) Peripheral vascular occlusive disease: accuracy and reliability of time-of-flight MR angiography. Radiology 192:351-357
    • (1994) Radiology , vol.192 , pp. 351-357
    • McCauley, T.R.1    Monib, A.2    Dickey, K.W.3
  • 23
    • 33846643027 scopus 로고    scopus 로고
    • Distal lower extremity imaging: Prospective comparison of 2-dimensional time of flight, 3-dimensional time-resolved contrast-enhanced magnetic resonance angiography, and 3-dimensional bolus chase contrast-enhanced magnetic resonance angiography
    • DOI 10.1097/01.rct.0000235073.72926.4d, PII 0000472820070100000006
    • Hahn WY, Hecht EM, Friedman B et al (2007) Distal lower extremity imaging: prospective comparison of 2-dimensional time of flight, 3-dimensional time-resolved contrast-enhanced magnetic resonance angiography, and 3-dimensional bolus chase contrast-enhanced magnetic resonance angiography. J Comput Assist Tomogr 31:29-36 (Pubitemid 46183339)
    • (2007) Journal of Computer Assisted Tomography , vol.31 , Issue.1 , pp. 29-36
    • Hahn, W.Y.1    Hecht, E.M.2    Friedman, B.3    Babb, J.S.4    Jacobowitz, G.R.5    Lee, V.S.6
  • 24
    • 58149389519 scopus 로고    scopus 로고
    • 3.0-T MR imaging of the abdomen: Comparison with 1.5 T
    • Chang KJ, Kamel IR, Macura KJ et al (2008) 3.0-T MR imaging of the abdomen: comparison with 1.5 T. Radiographics 28:1983-1998
    • (2008) Radiographics , vol.28 , pp. 1983-1998
    • Chang, K.J.1    Kamel, I.R.2    Macura, K.J.3
  • 25
    • 79959220481 scopus 로고    scopus 로고
    • Reduced acquisition window with parallel technique improves non contrast 3D HASTE MRA imaging
    • Xu J, Oesingmann N, Stemmer A et al (2006) Reduced acquisition window with parallel technique improves non contrast 3D HASTE MRA imaging. Proc Intl Soc Mag Reson Med 14:1931
    • (2006) Proc Intl Soc Mag Reson Med , vol.14 , pp. 1931
    • Xu, J.1    Oesingmann, N.2    Stemmer, A.3
  • 26
    • 2442671679 scopus 로고    scopus 로고
    • On improving temporal and spatial resolution of 3D contrast-enhanced body MR angiography with parallel imaging
    • DOI 10.1148/radiol.2313021113
    • Chen Q, Quijano CV, Mai VM et al (2004) On improving temporal and spatial resolution of 3D contrast-enhanced body MR angiography with parallel imaging. Radiology 231:893-899 (Pubitemid 38668114)
    • (2004) Radiology , vol.231 , Issue.3 , pp. 893-899
    • Chen, Q.1    Quijano, C.V.2    Mai, V.M.3    Krishnamoorthy, S.K.4    Li, W.5    Storey, P.6    Edelman, R.R.7
  • 28
    • 79959198796 scopus 로고    scopus 로고
    • NATIVE SPACE angiography with MTC and fat saturation pulses
    • Priatna A, Foster G, Xu J et al (2009) NATIVE SPACE angiography with MTC and fat saturation pulses. Proc Intl Soc Mag Reson Med 17:593
    • (2009) Proc Intl Soc Mag Reson Med , vol.17 , pp. 593
    • Priatna, A.1    Foster, G.2    Xu, J.3
  • 29
    • 51449096625 scopus 로고    scopus 로고
    • High-spatial-resolution three-dimensional MR cholangiography using a high-sampling-efficiency technique (SPACE) at 3 T: Comparison with the conventional constant flip angle sequence in healthy volunteers
    • Arizono S, Isoda H, Maetani YS et al (2008) High-spatial-resolution three-dimensional MR cholangiography using a high-sampling-efficiency technique (SPACE) at 3 T: comparison with the conventional constant flip angle sequence in healthy volunteers. J Magn Reson Imaging 28:685-690
    • (2008) J Magn Reson Imaging , vol.28 , pp. 685-690
    • Arizono, S.1    Isoda, H.2    Maetani, Y.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.