메뉴 건너뛰기




Volumn 21, Issue 6, 2011, Pages 1200-1206

Borderline breast lesions: Comparison of malignancy underestimation rates with 14-gauge core needle biopsy versus 11-gauge vacuum-assisted device

Author keywords

B3 lesions; Borderline breast lesions; Core needle biopsy; Papilloma; Vacuum assisted biopsy

Indexed keywords

ADULT; AGED; ARTICLE; ASSISTIVE TECHNOLOGY DEVICE; BIOPSY TECHNIQUE; BREAST BIOPSY; BREAST CARCINOMA; BREAST HYPERPLASIA; BREAST PAPILLOMA; CANCER DIAGNOSIS; CANCER SURGERY; CORE NEEDLE BIOPSY; DIAGNOSTIC IMAGING; FEMALE; HISTOLOGY; HUMAN; HUMAN TISSUE; INTERMETHOD COMPARISON; INTRACYSTIC PAPILLARY CARCINOMA; INTRADUCTAL CARCINOMA; INVASIVE DUCTAL CARCINOMA; INVASIVE LOBULAR CARCINOMA; INVASIVE PAPILLARY CARCINOMA; INVASIVE TUBULOLOBULAR CARCINOMA; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; RETROSPECTIVE STUDY; STEREOTACTIC BIOPSY; TUMOR BIOPSY; TUMOR DIAGNOSIS; VACUUM ASSISTED BIOPSY;

EID: 79959237385     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-010-2053-7     Document Type: Article
Times cited : (49)

References (37)
  • 1
    • 0036065866 scopus 로고    scopus 로고
    • Percutaneous image-guided core breast biopsy
    • Liberman L (2002) Percutaneous image-guided core breast biopsy. Radiol Clin N Am 40:483-500
    • (2002) Radiol Clin N Am , vol.40 , pp. 483-500
    • Liberman, L.1
  • 2
    • 0033900181 scopus 로고    scopus 로고
    • Clinical management issues in percutaneous core breast biopsy
    • Liberman L (2000) Clinical management issues in percutaneous core breast biopsy. Radiol Clin N Am 38:791-807
    • (2000) Radiol Clin N Am , vol.38 , pp. 791-807
    • Liberman, L.1
  • 3
    • 4444275728 scopus 로고    scopus 로고
    • Image-guided breast biopsy and management of high-risk lesions
    • Berg WA (2004) Image-guided breast biopsy and management of high-risk lesions. Radiol Clin N Am 42:935-946
    • (2004) Radiol Clin N Am , vol.42 , pp. 935-946
    • Berg, W.A.1
  • 4
    • 0036724605 scopus 로고    scopus 로고
    • Nonmalignant lesions in breast core needle biopsies. To excise or not to excise?
    • Jacobs TW, Connolly JL, Schnitt SJ (2002) Nonmalignant lesions in breast core needle biopsies. To excise or not to excise? Am J Surg Pathol 26:1095-1110
    • (2002) Am J Surg Pathol , vol.26 , pp. 1095-1110
    • Jacobs, T.W.1    Connolly, J.L.2    Schnitt, S.J.3
  • 5
    • 0033848916 scopus 로고    scopus 로고
    • Uncommon high-risk lesions of the breast diagnosed at stereotactic core-needle biopsy: Clinical importance
    • Philpotts LE, Shaheen NA, Jain KS, Carter D, Lee CH (2000) Uncommon high-risk lesions of the breast diagnosed at stereotactic core-needle biopsy: clinical importance. Radiology 216:831-837 (Pubitemid 30660861)
    • (2000) Radiology , vol.216 , Issue.3 , pp. 831-837
    • Philpotts, L.E.1    Shaheen, N.A.2    Jain, K.S.3    Carter, D.4    Lee, C.H.5
  • 6
    • 68849096949 scopus 로고    scopus 로고
    • Update on percutaneous needle biopsy of nonmalignant breast lesions
    • Johnson NB, Collins LC (2009) Update on percutaneous needle biopsy of nonmalignant breast lesions. Adv Anat Pathol 16:183-195
    • (2009) Adv Anat Pathol , vol.16 , pp. 183-195
    • Johnson, N.B.1    Collins, L.C.2
  • 7
    • 56649097345 scopus 로고    scopus 로고
    • Management of lesions of uncertain malignant potential on breast core needle histology: Vacuum-assisted excision as an alternative to surgical excision
    • Bilous M, Houssami N (2008) Management of lesions of uncertain malignant potential on breast core needle histology: vacuum-assisted excision as an alternative to surgical excision. Breast 17:543-544
    • (2008) Breast , vol.17 , pp. 543-544
    • Bilous, M.1    Houssami, N.2
  • 8
    • 34247264985 scopus 로고    scopus 로고
    • Borderline breast core needle histology: Predictive values for malignancy in lesions of uncertain malignant potential (B3)
    • DOI 10.1038/sj.bjc.6603714, PII 6603714
    • Houssami N, Ciatto S, Bilous M, Vezzosi BS (2007) Borderline breast core needle histology: predictive values for malignancy in lesions of uncertain malignant potential (B3). BJC 96:1253-1257 (Pubitemid 46625079)
    • (2007) British Journal of Cancer , vol.96 , Issue.8 , pp. 1253-1257
    • Houssami, N.1    Ciatto, S.2    Bilous, M.3    Vezzosi, V.4    Bianchi, S.5
  • 9
    • 57049153945 scopus 로고    scopus 로고
    • Predictive value of needle core biopsy diagnoses of lesions of uncertain malignant potential (B3) in abnormalities detected by mammographic screening
    • DOI 10.1111/j.1365-2559.2008.03158.x
    • El-Sayed ME, Rakha EA, Reed J, Lee AHS, Evans AJ, Ellis IO (2008) Predictive value of needle core biopsy diagnoses of lesions of uncertain malignant potential (B3) in abnormalities detected by mammographic screening. Histopathology 53:650-657 (Pubitemid 352768713)
    • (2008) Histopathology , vol.53 , Issue.6 , pp. 650-657
    • El-Sayed, M.E.1    Rakha, E.A.2    Reed, J.3    Lee, A.H.S.4    Evans, A.J.5    Ellis, I.O.6
  • 10
    • 0037391635 scopus 로고    scopus 로고
    • Excision biopsy findings of patients with breast needle core biopsies reported as suspicious of malignancy (B4) or lesion of uncertain malignant potential (B3)
    • Lee AHS, Denley HE, Pinder SE et al (2003) Excision biopsy findings of patients with breast needle core biopsies reported as suspicious of malignancy (B4) or lesion of uncertain malignant potential (B3). Histopathology 42:331-336
    • (2003) Histopathology , vol.42 , pp. 331-336
    • Lee, A.H.S.1    Denley, H.E.2    Pinder, S.E.3
  • 11
    • 33846598450 scopus 로고    scopus 로고
    • Predictive value of breast lesions of "uncertain malignant potential" determined by needle core biopsy
    • Dillon MF, McDermott EW, Hill AD, O'Doherty A, O'Higgins N, Quinn CM (2007) Predictive value of breast lesions of "uncertain malignant potential" determined by needle core biopsy. Ann Surg Oncol 14:704-711
    • (2007) Ann Surg Oncol , vol.14 , pp. 704-711
    • Dillon, M.F.1    McDermott, E.W.2    Hill, A.D.3    O'Doherty, A.4    O'Higgins, N.5    Quinn, C.M.6
  • 12
    • 41549146991 scopus 로고    scopus 로고
    • Borderline breast lesions diagnosed at core needle biopsy: Can magnetic resonance mammography rule out associated malignancy? Preliminary results based on 79 surgically excised lesions
    • Linda A, Zuiani C, Bazzocchi M, Furlan A, Londero V (2008) Borderline breast lesions diagnosed at core needle biopsy: can magnetic resonance mammography rule out associated malignancy? Preliminary results based on 79 surgically excised lesions. Breast 17:125-31
    • (2008) Breast , vol.17 , pp. 125-131
    • Linda, A.1    Zuiani, C.2    Bazzocchi, M.3    Furlan, A.4    Londero, V.5
  • 13
    • 0036721251 scopus 로고    scopus 로고
    • To excise or to sample the mammographic target: What is the goal of stereotactic 11-gauge vacuum assisted breast biopsy?
    • Liberman L, Kaplan JB, Morris EA, Abramson AF, Menell JH, Dershaw DD (2002) To excise or to sample the mammographic target: what is the goal of stereotactic 11-gauge vacuum assisted breast biopsy? AJR Am J Roentgenol 179:679-683
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 679-683
    • Liberman, L.1    Kaplan, J.B.2    Morris, E.A.3    Abramson, A.F.4    Menell, J.H.5    Dershaw, D.D.6
  • 14
    • 33645120598 scopus 로고    scopus 로고
    • Breast microcalcifications: Retrieval failure at prone stereotactic core vacuum breast biopsy-Frequency, causes and outcome
    • Jackman RJ, Rodriguez-Soto J (2006) Breast microcalcifications: retrieval failure at prone stereotactic core vacuum breast biopsy-Frequency, causes and outcome. Radiology 239:61-70
    • (2006) Radiology , vol.239 , pp. 61-70
    • Jackman, R.J.1    Rodriguez-Soto, J.2
  • 15
    • 0030787433 scopus 로고    scopus 로고
    • Atypical ductal hyperplasia diagnosed at stereotactic breast biopsy: Improved reliability with 14-gauge, directional, vacuum-assisted biopsy
    • Jackman RJ, Burbank F, Parker SH, Evans WP 3rd, Lechner MC, Richardson TR et al (1997) Atypical ductal hyperplasia diagnosed at stereotactic breast biopsy: improved reliability with 14-gauge, directional, vacuum-assisted biopsy. Radiology 204:485-488 (Pubitemid 27337499)
    • (1997) Radiology , vol.204 , Issue.2 , pp. 485-488
    • Jackman, R.J.1    Burbank, F.2    Parker, S.H.3    Evans III, W.P.4    Lechner, M.C.5    Richardson, T.R.6    Tocino, I.7    Wray, A.B.8
  • 16
    • 0033030531 scopus 로고    scopus 로고
    • Comparison of rebiopsy rates after stereotactic core needle biopsy of the breast with 11-gauge vacuum suction probe versus 14-gauge needle and automatic gun
    • Philpotts LE, Shaheen NA, Carter D, Lange RC, Lee CH (1999) Comparison of rebiopsy rates after stereotactic core needle biopsy of the breast with 11-gauge vacuum suction probe versus 14-gauge needle and automatic gun. AJR Am J Roentgenol 172:683-687 (Pubitemid 29102132)
    • (1999) American Journal of Roentgenology , vol.172 , Issue.3 , pp. 683-687
    • Philpotts, L.E.1    Shaheen, N.A.2    Carter, D.3    Lange, R.C.4    Lee, C.H.5
  • 18
    • 35648951149 scopus 로고    scopus 로고
    • Stereotactic breast biopsy: Comparison of underestimation rates with 11- and 9-gauge vacuum assisted breast biopsy
    • Lourenco AP, Mainiero MB, Lazarus E, Giri D, Schepps B (2007) Stereotactic breast biopsy: comparison of underestimation rates with 11- and 9-gauge vacuum assisted breast biopsy. AJR Am J Roentgenol 189:W275-W279
    • (2007) AJR Am J Roentgenol , vol.189
    • Lourenco, A.P.1    Mainiero, M.B.2    Lazarus, E.3    Giri, D.4    Schepps, B.5
  • 20
    • 39049119772 scopus 로고    scopus 로고
    • Modern concepts of ductal carcinoma in situ (DCIS) and its diagnosis through percutaneous biopsy
    • Kettritz U (2008) Modern concepts of ductal carcinoma in situ (DCIS) and its diagnosis through percutaneous biopsy. Eur Radiol 18:343-350
    • (2008) Eur Radiol , vol.18 , pp. 343-350
    • Kettritz, U.1
  • 21
    • 17744418366 scopus 로고    scopus 로고
    • Interdisciplinary consensus on the use and technique of vacuum-assisted stereotactic breast biopsy
    • DOI 10.1016/S0720-048X(02)00196-1, PII S0720048X02001961
    • Heywang-Kobrunner SH, Schreer I, Decker T, Bocker W (2003) Interdisciplinary consensus on the use and technique of vacuum assisted stereotactic breast biopsy. Eur J Radiol 47:232-236 (Pubitemid 36970085)
    • (2003) European Journal of Radiology , vol.47 , Issue.3 , pp. 232-236
    • Heywang-Kobrunner, S.H.1    Schreer, I.2    Decker, T.3    Bocker, W.4
  • 22
    • 65649086823 scopus 로고    scopus 로고
    • Excision of high-risk breast lesions on needle biopsy: Is there a standard of core?
    • Lawton TJ, Georgian-Smith D (2009) Excision of high-risk breast lesions on needle biopsy: is there a standard of core? AJR Am J Roentgenol 192:268
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 268
    • Lawton, T.J.1    Georgian-Smith, D.2
  • 23
    • 69949164954 scopus 로고    scopus 로고
    • Pathology of B3 lesions of the breast
    • Hayes BD, Quinn CM (2009) Pathology of B3 lesions of the breast. Diagn Histopathol 15:459-469
    • (2009) Diagn Histopathol , vol.15 , pp. 459-469
    • Hayes, B.D.1    Quinn, C.M.2
  • 24
    • 73449106141 scopus 로고    scopus 로고
    • Correlation of needle core biopsy with excision histology in screen-detected B3 lesions: The Merriot Breast Screening Unit experience
    • Hayes BD, O'Doherty A, Quinn CM (2009) Correlation of needle core biopsy with excision histology in screen-detected B3 lesions: the Merriot Breast Screening Unit experience. J Clin Pathol 62:1136-1140
    • (2009) J Clin Pathol , vol.62 , pp. 1136-1140
    • Hayes, B.D.1    O'Doherty, A.2    Quinn, C.M.3
  • 25
    • 54849403784 scopus 로고    scopus 로고
    • Screen-detected breast lesions with an indeterminate (B3) core needle biopsy should be excised
    • Lieske B, Ravichandran D, Alvi A, Lawrence DAS, Wright DJ (2008) Screen-detected breast lesions with an indeterminate (B3) core needle biopsy should be excised. Eur J Surg Oncol 34:1293-1298
    • (2008) Eur J Surg Oncol , vol.34 , pp. 1293-1298
    • Lieske, B.1    Ravichandran, D.2    Alvi, A.3    Lawrence, D.A.S.4    Wright, D.J.5
  • 27
    • 14844302386 scopus 로고    scopus 로고
    • Needle core biopsy can reliably distinguish between benign and malignant papillary lesions of the breast
    • DOI 10.1111/j.1365-2559.2005.02082.x
    • Carder PJ, Garvican J, Hiagh I, Liston JC (2005) Needle core biopsy can reliably distinguish between benign and malignant papillary lesions of the breast. Histopathology 46:320-327 (Pubitemid 40343179)
    • (2005) Histopathology , vol.46 , Issue.3 , pp. 320-327
    • Carder, P.J.1    Garvican, J.2    Haigh, I.3    Liston, J.C.4
  • 28
    • 57749088472 scopus 로고    scopus 로고
    • Pre-operative diagnosis of breast cancer in screening: Problems and pitfalls
    • Provenzano E, Pinder SE (2009) Pre-operative diagnosis of breast cancer in screening: problems and pitfalls. Pathology 41:3-17
    • (2009) Pathology , vol.41 , pp. 3-17
    • Provenzano, E.1    Pinder, S.E.2
  • 29
    • 57749096252 scopus 로고    scopus 로고
    • Update on atypical epithelial hyperplasia and ductal carcinoma in situ
    • Simpson JF (2009) Update on atypical epithelial hyperplasia and ductal carcinoma in situ. Pathology 41:36-39
    • (2009) Pathology , vol.41 , pp. 36-39
    • Simpson, J.F.1
  • 30
    • 33745859981 scopus 로고    scopus 로고
    • Radial scars diagnosed at stereotactic core-needle biopsy: Surgical biopsy findings
    • DOI 10.1007/s00330-006-0196-3
    • Lopez-Medina A, Cintora E, Mugica B, Operé E, Vela AC, Ibanez T (2006) Radial Scars diagnosed at stereotactic core-needle biopsy: surgical biopsy findings. Eur Radiol 16:1803-1810 (Pubitemid 44027384)
    • (2006) European Radiology , vol.16 , Issue.8 , pp. 1803-1810
    • Lopez-Medina, A.1    Cintora, E.2    Mugica, B.3    Opere, E.4    Vela, A.C.5    Ibanez, T.6
  • 31
    • 0030770302 scopus 로고    scopus 로고
    • Evaluation of 14- and 11-gauge directional vacuum-assisted biopsy probes and 14-gauge biopsy gun in a breast parenchymal model
    • Berg WA, Krebs TL, Campassi C, Magder LS, Sun C-CJ (1997) Evaluation of 14- and 11-gauge directional vacuum-assisted biopsy probes and 14-gauge biopsy gun in a breast parenchymal model. Radiology 205:203-208
    • (1997) Radiology , vol.205 , pp. 203-208
    • Berg, W.A.1    Krebs, T.L.2    Campassi, C.3    Magder, L.S.4    Sun, C.-C.J.5
  • 32
    • 0029759194 scopus 로고    scopus 로고
    • Stereotactic breast biopsy: Improved tissue harvesting with the Mammotome
    • Burbank F, Parker SH, Fogarty TJ (1996) Stereotactic breast biopsy: improved tissue harvesting with the Mammotome. Am Surg 62:738-744 (Pubitemid 26309056)
    • (1996) American Surgeon , vol.62 , Issue.9 , pp. 738-744
    • Burbank, F.1    Parker, S.H.2    Fogarty, T.J.3
  • 33
    • 0030774099 scopus 로고    scopus 로고
    • Stereotactic breast biopsy: Comparison of 14- and 11-gauge Mammotome probe performance and complication rates
    • Burbank F (1997) Stereotactic breast biopsy: comparison of 14- and 11-gauge Mammotome probe performance and complication rates. Am Surg 63:988-995
    • (1997) Am Surg , vol.63 , pp. 988-995
    • Burbank, F.1
  • 34
    • 0031771461 scopus 로고    scopus 로고
    • Percutaneous removal of benign mammographic lesions: Comparison of automated large-core and directional vacuum-assisted stereotactic biopsy techniques
    • Jackman R, Marzoni FA, Nowels KW (1998) Percutaneous removal of benign mammographic lesions: comparison of automated large-core and directional vacuum-assisted stereotactic biopsy techniques. AJR Am J Roentgenol 171:1325-1330 (Pubitemid 28489422)
    • (1998) American Journal of Roentgenology , vol.171 , Issue.5 , pp. 1325-1330
    • Jackman, R.J.1    Marzoni Jr., F.A.2    Nowels, K.W.3
  • 35
    • 0031931765 scopus 로고    scopus 로고
    • Percutaneous removal of malignant mammographic lesions at stereotactic vacuum-assisted biopsy
    • Liberman L, Dershaw DD, Rosen PP, Morris EA, Abramson AF, Borgen PI (1998) Percutaneous removal of malignant mammographic lesions at stereotactic vacuum-assisted biopsy. Radiology 206:711-715
    • (1998) Radiology , vol.206 , pp. 711-715
    • Liberman, L.1    Dershaw, D.D.2    Rosen, P.P.3    Morris, E.A.4    Abramson, A.F.5    Borgen, P.I.6
  • 36
    • 0037306907 scopus 로고    scopus 로고
    • Comparison of automated versus vacuum-assisted biopsy methods for sonographically guided core biopsy of the breast
    • Philpotts L, Hooley RJ, Lee CH (2003) Comparison of automated versus vacuum-assisted biopsy methods for sonographically guided core biopsy of the breast. AJR Am J Roentgenol 180:347-351 (Pubitemid 36135012)
    • (2003) American Journal of Roentgenology , vol.180 , Issue.2 , pp. 347-351
    • Philpotts, L.E.1    Hooley, R.J.2    Lee, C.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.