메뉴 건너뛰기




Volumn 21, Issue 2, 2011, Pages 102-112

Influence of tissue conductivity changes on the EEG signal in the human brain - A simulation study

Author keywords

EEG; Electric Conductivity Tensor; Ischemia; Tissue Anisotropy; Vasogenic Edema

Indexed keywords

ANISOTROPY; ARTICLE; BRAIN EDEMA; BRAIN ISCHEMIA; BRAIN TUMOR; CONTROLLED STUDY; ELECTRIC CONDUCTIVITY; ELECTRIC POTENTIAL; ELECTROENCEPHALOGRAM; SIMULATION;

EID: 79959221009     PISSN: 09393889     EISSN: 18764436     Source Type: Journal    
DOI: 10.1016/j.zemedi.2010.07.004     Document Type: Article
Times cited : (11)

References (19)
  • 3
    • 67651162180 scopus 로고    scopus 로고
    • Electrical conductivity measurement of excised human metastatic liver tumours before and after thermal ablation
    • Haemmerich D., Schutt D.J., Wright A.W., Webster J.G., Mahvi D.M. Electrical conductivity measurement of excised human metastatic liver tumours before and after thermal ablation. Physiol Meas 2009, 30(5):459-466.
    • (2009) Physiol Meas , vol.30 , Issue.5 , pp. 459-466
    • Haemmerich, D.1    Schutt, D.J.2    Wright, A.W.3    Webster, J.G.4    Mahvi, D.M.5
  • 4
    • 53149084121 scopus 로고    scopus 로고
    • Opening of the blood-brain barrier during isoflurane anaesthesia
    • Tétrault S., Chever O., Sik A., Amzica F. Opening of the blood-brain barrier during isoflurane anaesthesia. Eur J Neurosci 2008, 28(7):1330-1341.
    • (2008) Eur J Neurosci , vol.28 , Issue.7 , pp. 1330-1341
    • Tétrault, S.1    Chever, O.2    Sik, A.3    Amzica, F.4
  • 5
    • 77950542956 scopus 로고    scopus 로고
    • Influence of anisotropic electrical conductivity in white matter tissue on the EEG/MEG forward and inverse solution - A high resolution whole head simulation study
    • Güllmar D., Haueisen J., Reichenbach J.R. Influence of anisotropic electrical conductivity in white matter tissue on the EEG/MEG forward and inverse solution - A high resolution whole head simulation study. Neuroimage 2010, 51(1):145-163.
    • (2010) Neuroimage , vol.51 , Issue.1 , pp. 145-163
    • Güllmar, D.1    Haueisen, J.2    Reichenbach, J.R.3
  • 6
    • 84856805563 scopus 로고    scopus 로고
    • Simulation der Auswirkung von Veränderungen der anisotropen elektrischen Leitfähigkeit im Gewebe des menschlichen Gehirns auf die Elektroenzephalographie. Diplomarbeit, Friedrich-Schiller-Universität Jena
    • Jochmann T. Simulation der Auswirkung von Veränderungen der anisotropen elektrischen Leitfähigkeit im Gewebe des menschlichen Gehirns auf die Elektroenzephalographie. Diplomarbeit, Friedrich-Schiller-Universität Jena 2009.
    • (2009)
    • Jochmann, T.1
  • 8
    • 2142692175 scopus 로고    scopus 로고
    • Dielectric properties of porcine brain tissue in the transition from life to death at frequencies from 800 to 1900MHz
    • Schmid G., Neubauer G., Illievich U.M., Alesch F. Dielectric properties of porcine brain tissue in the transition from life to death at frequencies from 800 to 1900MHz. Bioelectromagnetics 2003, 24:413-422.
    • (2003) Bioelectromagnetics , vol.24 , pp. 413-422
    • Schmid, G.1    Neubauer, G.2    Illievich, U.M.3    Alesch, F.4
  • 10
    • 84983725688 scopus 로고    scopus 로고
    • Estimation of in vivo human brain-to-skull conductivity ratio from simultaneous extra- and intra-cranial electrical potential recordings
    • Lai Y., van Drongelen W., Ding L., Hecox K., Towle V., Frim D., He B. Estimation of in vivo human brain-to-skull conductivity ratio from simultaneous extra- and intra-cranial electrical potential recordings. Clin Neurophysiol 2005, 116(2):456-465.
    • (2005) Clin Neurophysiol , vol.116 , Issue.2 , pp. 456-465
    • Lai, Y.1    van Drongelen, W.2    Ding, L.3    Hecox, K.4    Towle, V.5    Frim, D.6    He, B.7
  • 12
    • 9644307843 scopus 로고    scopus 로고
    • Estimating brain conductivities and dipole source signals with EEG arrays
    • Gutiérrez D., Nehorai A., Muravchik C. Estimating brain conductivities and dipole source signals with EEG arrays. IEEE Trans Biomed Eng 2004, 51(12):2113-2122.
    • (2004) IEEE Trans Biomed Eng , vol.51 , Issue.12 , pp. 2113-2122
    • Gutiérrez, D.1    Nehorai, A.2    Muravchik, C.3
  • 13
    • 0013840402 scopus 로고
    • Specific impedance of cerebral white matter
    • Nicholson P. Specific impedance of cerebral white matter. Exp Neurol 1965, 13:386-401.
    • (1965) Exp Neurol , vol.13 , pp. 386-401
    • Nicholson, P.1
  • 14
    • 67349285729 scopus 로고    scopus 로고
    • Accuracy and run-time comparison for different potential approaches and iterative solvers in finite element method based EEG source analysis
    • Lew S., Wolters C.H., Dierkes T., Röer C., MacLeod R.S. Accuracy and run-time comparison for different potential approaches and iterative solvers in finite element method based EEG source analysis. Appl Numer Math 2009, 59:1970-1988.
    • (2009) Appl Numer Math , vol.59 , pp. 1970-1988
    • Lew, S.1    Wolters, C.H.2    Dierkes, T.3    Röer, C.4    MacLeod, R.S.5
  • 15
    • 4043054367 scopus 로고    scopus 로고
    • Efficient computation of lead field bases and influence matrix for the FEM-based EEG and MEG inverse problem
    • Wolters C.H., Grasedyck L., Hackbusch W. Efficient computation of lead field bases and influence matrix for the FEM-based EEG and MEG inverse problem. Inverse Problems 2004, 20(4):1099-1116.
    • (2004) Inverse Problems , vol.20 , Issue.4 , pp. 1099-1116
    • Wolters, C.H.1    Grasedyck, L.2    Hackbusch, W.3
  • 16
    • 84856795064 scopus 로고    scopus 로고
    • SCIRun. A scientific computing problem solving environment. Sci Comput Imag Inst. , accessed online 18.03.2010.
    • SCIRun. A scientific computing problem solving environment. Sci Comput Imag Inst. , accessed online 18.03.2010. http://www.sci.utah.edu/cibc/software/106-scirun.html.
  • 17
    • 77049286773 scopus 로고
    • Specific resistance of body tissues
    • Schwan H.P., Kay C.F. Specific resistance of body tissues. Circ Res 1956, 4(6):664-670.
    • (1956) Circ Res , vol.4 , Issue.6 , pp. 664-670
    • Schwan, H.P.1    Kay, C.F.2
  • 18
    • 36749006648 scopus 로고    scopus 로고
    • Application of diffusion tensor imaging in neurosurgery
    • German
    • Saur R., Gharabaghi A., Erb M. Application of diffusion tensor imaging in neurosurgery. Z Med Phys 2007, 17(4):258-265. German.
    • (2007) Z Med Phys , vol.17 , Issue.4 , pp. 258-265
    • Saur, R.1    Gharabaghi, A.2    Erb, M.3
  • 19
    • 33745904734 scopus 로고    scopus 로고
    • Update on Brain Tumor Imaging: From Anatomy to Physiology
    • Cha S. Update on Brain Tumor Imaging: From Anatomy to Physiology. AJNR Am J Neuroradiol 2006, 27(3):475-487.
    • (2006) AJNR Am J Neuroradiol , vol.27 , Issue.3 , pp. 475-487
    • Cha, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.