Optimized low-kV spectrum of dual-energy CT equipped with high-kV tin filtration for electron density measurements

Author keywords

beam hardening; dual energy CT; effective atomic number; electron density; tin filter

Indexed keywords

ATOMS; BONE; CARRIER CONCENTRATION; COMPUTERIZED TOMOGRAPHY; ELECTRON DENSITY MEASUREMENT; ELECTRONS; ERRORS; HARDENING; MAMMOGRAPHY; PHANTOMS; TIN; TUBES (COMPONENTS);

EID: 79958838949     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3584200     Document Type: Article
Times cited : (10)

References (17)
  • 1
    • 0017108614 scopus 로고
    • Energy-selective reconstructions in x-ray CT
    • 10.1088/0031-9155/21/5/002
    • R. E. Alvarez and A. Macovski, Energy-selective reconstructions in x-ray CT., Phys. Med. Biol. 21 (5), 733-744 (1976). 10.1088/0031-9155/21/5/002
    • (1976) Phys. Med. Biol. , vol.21 , Issue.5 , pp. 733-744
    • Alvarez, R.E.1    MacOvski, A.2
  • 2
    • 0022528983 scopus 로고
    • Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies
    • DOI 10.1118/1.595958
    • W. A. Kalender, W. H. Perman, J. R. Vetter, and E. Klotz, Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies., Med. Phys. 13 (3), 334-339 (1986). 10.1118/1.595958 (Pubitemid 16062265)
    • (1986) Medical Physics , vol.13 , Issue.3 , pp. 334-339
    • Kalender, W.A.1    Perman, W.H.2    Vetter, J.R.3    Klotz, E.4
  • 3
    • 63849101176 scopus 로고    scopus 로고
    • Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration
    • 10.1118/1.3083567
    • A. N. Primak, J. C. Ramirez Giraldo, X. Liu, L. Yu, and C. H. McCollough, Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration., Med. Phys. 36 (4), 1359-1369 (2009). 10.1118/1.3083567
    • (2009) Med. Phys. , vol.36 , Issue.4 , pp. 1359-1369
    • Primak, A.N.1    Ramirez Giraldo, J.C.2    Liu, X.3    Yu, L.4    McCollough, C.H.5
  • 4
    • 78149478382 scopus 로고    scopus 로고
    • Technical note: Optimization for improved tube-loading efficiency in the dual-energy computed tomography coupled with balanced filter method
    • 10.1118/1.3467754
    • M. Saito, Technical note: optimization for improved tube-loading efficiency in the dual-energy computed tomography coupled with balanced filter method., Med. Phys. 37 (8), 4182-4185 (2010). 10.1118/1.3467754
    • (2010) Med. Phys. , vol.37 , Issue.8 , pp. 4182-4185
    • Saito, M.1
  • 6
    • 68149162621 scopus 로고    scopus 로고
    • Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method
    • 10.1118/1.3157098
    • M. Saito, Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method., Med. Phys. 36 (8), 3631-3642 (2009). 10.1118/1.3157098
    • (2009) Med. Phys. , vol.36 , Issue.8 , pp. 3631-3642
    • Saito, M.1
  • 7
    • 44349119806 scopus 로고    scopus 로고
    • Monte Carlo evaluation of CTDI∞ in infinitely long cylinders of water, polyethylene and PMMA with diameters from 10 mm to 500 mm
    • DOI 10.1118/1.2921829
    • H. Zhou and J. M. Boone, Monte Carlo evaluation of CTDI (infinity) in infinitely long cylinders of water, polyethylene and PMMA with diameters from 10 mm to 500 mm., Med. Phys. 35 (6), 2424-2431 (2008). 10.1118/1.2921829 (Pubitemid 351748650)
    • (2008) Medical Physics , vol.35 , Issue.6 , pp. 2424-2431
    • Zhou, H.1    Boone, J.M.2
  • 8
    • 0032692240 scopus 로고    scopus 로고
    • A simple theorem relating noise and patient dose in computed tomography
    • 10.1118/1.598778
    • M. D. Harpen, A simple theorem relating noise and patient dose in computed tomography., Med. Phys. 26 (11), 2231-2234 (1999). 10.1118/1.598778
    • (1999) Med. Phys. , vol.26 , Issue.11 , pp. 2231-2234
    • Harpen, M.D.1
  • 9
    • 0003414651 scopus 로고
    • Photon, Electron, Proton, and Neutron Interaction Data for Body Tissues
    • International Commission on Radiation Units and Measurements, , (ICRU Publications, Bethesda, MD).
    • International Commission on Radiation Units and Measurements, Photon, Electron, Proton, and Neutron Interaction Data for Body Tissues., ICRU Report No. 46 (ICRU Publications, Bethesda, MD, 1992).
    • (1992) ICRU Report No. 46
  • 10
    • 42449122744 scopus 로고    scopus 로고
    • Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations
    • DOI 10.1088/0031-9155/53/9/015, PII S0031915508683165
    • M. Bazalova, J.-F. Carrier, L. Beaulieu, and F. Verhaegen, Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations., Phys. Med. Biol. 53 (9), 2439-2456 (2008). 10.1088/0031-9155/53/ 9/015 (Pubitemid 351570921)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.9 , pp. 2439-2456
    • Bazalova, M.1    Carrier, J.-F.2    Beaulieu, L.3    Verhaegen, F.4
  • 12
    • 0003310199 scopus 로고
    • The significance of the Roentgen
    • W. V. Mayneord, The significance of the Roentgen., Acta Int. Union Cancer 2, 271-282 (1937).
    • (1937) Acta Int. Union Cancer , vol.2 , pp. 271-282
    • Mayneord, W.V.1
  • 14
    • 36349008732 scopus 로고    scopus 로고
    • Intensity distribution and impact of scatter for dual-source CT
    • DOI 10.1088/0031-9155/52/23/014, PII S0031915507547536
    • Y. Kyriakou and W. A. Kalender, Intensity distribution and impact of scatter for dual-source CT., Phys. Med. Biol. 52 (23), 6969-6989 (2007). 10.1088/0031-9155/52/23/014 (Pubitemid 350150626)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.23 , pp. 6969-6989
    • Kyriakou, Y.1    Kalender, W.A.2
  • 15
    • 37549072259 scopus 로고    scopus 로고
    • X-ray scattering in single- and dual-source CT
    • 10.1118/1.2820901
    • K. J. Engel, C. Herrmann, and G. Zeitler, X-ray scattering in single- and dual-source CT., Med. Phys. 35 (1), 318-332 (2008). 10.1118/1.2820901
    • (2008) Med. Phys. , vol.35 , Issue.1 , pp. 318-332
    • Engel, K.J.1    Herrmann, C.2    Zeitler, G.3
  • 16
    • 54949155209 scopus 로고    scopus 로고
    • Measurement of electron density in dual-energy x-ray CT with monochromatic x rays and evaluation of its accuracy
    • 10.1118/1.2987738
    • T. Tsunoo, M. Torikoshi, Y. Ohno, K. Uesugi, and N. Yagi, Measurement of electron density in dual-energy x-ray CT with monochromatic x rays and evaluation of its accuracy., Med. Phys. 35 (11), 4924-4932 (2008). 10.1118/1.2987738
    • (2008) Med. Phys. , vol.35 , Issue.11 , pp. 4924-4932
    • Tsunoo, T.1    Torikoshi, M.2    Ohno, Y.3    Uesugi, K.4    Yagi, N.5
  • 17
    • 78149455882 scopus 로고    scopus 로고
    • Strategies for scatter correction in dual source CT
    • 10.1118/1.3504606
    • M. Petersilka, K. Stierstorfer, H. Bruder, and T. Flohr, Strategies for scatter correction in dual source CT., Med. Phys. 37 (11), 5971-5992 (2010). 10.1118/1.3504606
    • (2010) Med. Phys. , vol.37 , Issue.11 , pp. 5971-5992
    • Petersilka, M.1    Stierstorfer, K.2    Bruder, H.3    Flohr, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.